9
1.3 Power supply installation
1.3.1 Power supply
It is highly recommended to install leakage protector, and the decoupling current of
leakage protector shall not be less than 30mA.
At least select standard type (class B standard) circuit breaker sensitive to electrical signal
mutation. These abrupt signals are generated when the kitchen appliances (including
microwave oven) such as freezer and refrigerator are opened. We strongly recommend the
use of class C standard (specially designed for these appliances) circuit breakers. Each oven
must have an appropriate capacity circuit breaker when there are multiple ovens.
This equipment is in accordance with EN61000-3-11 standard. Because the oven will interfere
with the power supply circuit, it should be approved by the power supply department before
connecting the power supply. If necessary, use a low impedance power supply.
1.3.2 Power cable connection
Please use the power cord to connect the device with the automatic circuit breaker and then
the power supply. See the diagram above.
1.3.3 Single phase
The connection of single-phase power supply is shown in the picture.
Models sold in the UK have a blue 32A plug with the symbol IEC 60309 (EN 60309).
The rated current of circuit breaker (Class C standard) is 40A.