10
2. Device parameters
2.1 Product parameters table
Model
MICRO-1217HS
Dimension(mm)
460X675X660
Chamber(mm)
305X305X185
Capacity(L)
17
Net Weight(KG)
66
Voltage(V)
208-240V~
Frequency
50/60Hz
Rated Power(KW)
3.3
Controller
5” Touch Screen
Consult a qualified electrician if doubt
exists on electric connection.
Danger!
This product must be grounded, or it may cause
electric shock or even death.
The electrical wiring of the equipment must be
connected to a separate power supply by a
qualified electrical technician.
Each device must be fitted with a double-way
insulated switch with an appropriate rated capacity
and contact spacing more than 3mm
Warning!
If the power supply is outside, please pay
attention to the water proof and dust proof
measures
Equipotential
The back of the equipment has an equipotential
ground point for separate grounding (GND)
Warning!
When connecting the power cord, make sure the
connection of each core wire is firm and the power
cord is locked tightly. Even if the power cord is acted
upon by external force, the connecting terminals will
not be loosened due to external force, otherwise it
may cause danger. Use normal PVC power cord,
result in electric leakage because of aging or crack.
Warning!
To avoid the risk due to worn power cord,
bushing must be installed at the outlet of the
power cord and at the hole through which the
power cord passes
Warning!
When connecting the ground wire, ensure
that the power cord is connected to the
ground wire terminal when acted upon by
external forces
Caution!
When the length of the power cord is
insufficient, please REPLACE with a new
power cord with sufficient length. DO NOT
CONNECT
TWO
POWER
CORDS
TOGETHER FOR EXTENTSION