Technical information ACCESS-IT UNIT
p.37/42
This menu comprises:
Select the input to use as well as the type of contact, to
watch for unauthorised entry into the enclosure.
Two successive swipes of a badge through the same
reader not allowed. For this, a valid badge must enter
through an entry reader and exit via an exit reader.
(The readers must therefore be configured in the
corresponding menu).
Activate / Deactivate the control unit’s radio input.
Select the anti time back delay (time after which
a badge outside the cycle can re-enter/exit again).
Select the transit delay time (maximum time after
which a badge accepted on reader 1 will not be
on reader 2 and vice versa).
Activate / Deactivate the summer / winter time
function.
Defines the reader alert level to be recognised
by the control unit.
Defines the communication protocol to be used for
reader 1. Scroll through the different types of reader,
using the (+) and (-) keys.
The following types of reader are available:
HID
Management of Wiegand protocols (management of the last bits sent
by the reader). The number of bits is configurable between 16 and 32.
HID Decimal
Management of Wiegand decimal protocols (management of the last bits sent
by the reader). The number of bits is configurable between 16 and 32.
Wiegand custom
Choice between 26-bit Wiegand (with or without management of site code)
and 30-bit Wiegand (with or without management of site and distributor codes).
ABA / ISO2
Management of ABA protocol (management of the last characters sent
by the reader). The number of characters is configurable between 5 and 8.
BIOVEIN
Management of BIOVEIN reader
ACCESS IT BIO /
SOLO
Managment of Access It Bio / Solo reader.
UNAUTHORISED
ENTRY INTO
ENCLOSURE
ANTI-PaASS-BACK
DEACTIVATED
RADIO INPUT?
ACTIVATED
ANTI-TIME-BACK
DEACTIVATED
TRANSIT DELAY
DEACTIVATED
SUMMER TIME?
DEACTIVATED
ALERT LEVEL?
0
STANDARD READER
TYPE 1