Microtrac™
Document: UMDB007595.docm
Revision: B13
Created by: KB
Date: 17 Nov 2019
IPN: 3042830-B13
Source Location: C:\ePDM\ISLEng\products\db-microtracs4000\manuals\UMDB007595.docm
Page 23 of 26
User Ma
nual
3. Ensure that all fasteners are in place and secure.
Weekly
1.
Tracks with Spring Tensioners
- In addition to the daily check, examine the condition of the
tension springs at least once per week. Worn or corroded springs may weaken and cause low
belt tension and idler wheel misalignment.
2. Verify by visual inspection that there are no traces of grease near or on the sides of the drive
wheel and the track belt. This would indicate that the grease seals may have been damaged by
debris or have become worn by abrasion.
3. If necessary, remove the belt and thoroughly clean the track.
Overhaul
Eddyfi recommends that the Microtracs
™ be thoroughly serviced once a year or after 600 hours of
operation. This includes complete disassembly, cleaning and inspection of the Microtrac components
with focus on the drivetrain, bearings, output shaft and seals. At this time the track is re-lubricated.
For extended service and maximum reliability of your Microtracs, Eddyfi offers a factory overhaul. The
factory overhaul constitutes an investment by the equipment owner in preventative maintenance. As
such, the overhaul should be considered discretionary. In the overhaul, the track unit is completely
disassembled. All internal components including the motor, driver, bevel gears, bearings, and seals are
inspected and replaced where necessary.