ECTIVE SI & TSI Series
41
Recommended surrounding conditions
Operating temperature
-15 °C to 40 °C
Storage temperature
-40 °C to 85 °C
Relative humidity
20 % ~ 90 %
Please note!
Please mind the starting current!
Keep in mind that inductive devices (for example power drills or refrigerators etc.) often
need a 3–10 times higher power at the beginning than indicated on the descriptive type
plate. The maximum power of this short period should not surpass the maximum power
of the inverter.
Please note!
Listen to the acoustic signal!
In case of overload an acoustic signal will sound. If the needed power is not reduced to
the maximal continuous output, the inverter will shut down automatically.
Please note!
Output losses because of heat
An ambient temperature over 40°C (for ex. due to heat at the installation site or direct
sunlight) can lower the specified output and efficiency.