background image

Electromagnetic signal converter

Electronic Revision ER 4.

0

.

2

IFC 070

IFC 070

IFC 070

IFC 070

Quick Start 

Quick Start 

Quick Start 

Quick Start 

© KROHNE 11/2010 - 7311222400 - QS IFC 070 R04 en

The documentation is only complete when used in combination with the relevant 
documentation for the sensor.

Summary of Contents for IFC 070

Page 1: ...vision ER 4 0 2_ IFC 070 IFC 070 IFC 070 IFC 070 Quick Start Quick Start Quick Start Quick Start KROHNE 11 2010 7311222400 QS IFC 070 R04 en The documentation is only complete when used in combination with the relevant documentation for the sensor ...

Page 2: ...sport 5 2 4 Pre installation requirements 5 2 5 Installation requirements 6 2 5 1 Vibration 6 2 5 2 Magnetic field 6 2 5 3 Installation of converter 6 3 Electrical connections 7 3 1 Safety instructions 7 3 2 Grounding 7 3 3 Signal cable 8 3 4 Connection of signal cable 8 4 Start up 9 4 1 Connection of battery 9 4 1 1 Internal battery 9 4 1 2 External battery 10 5 Notes 11 ...

Page 3: ...an result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation assembly start up and maintenance may only be performed by appropriately trained personnel The regional occupational health and safety directives must always be observed LEGAL NOTICE The responsibility as to the suita...

Page 4: ...local office of the manufacturer INFORMATION Check the packing list to check if you received completely all that you ordered INFORMATION Look at the device nameplate to ensure that the device is delivered according to your order Check for the correct supply voltage printed on the nameplate Figure 2 1 Scope of delivery 1 Ordered flowmeter 2 Quick Start 3 Factory calibration report 4 CD ROM with pro...

Page 5: ...3 Transport 2 4 Pre installation requirements Make sure that you have all necessary tools available Allen key 4 mm Small screwdriver Wrench for cable glands Wrench for wall mounting bracket remote version only Torque wrench for installing flowmeter in pipeline Figure 2 2 Transport ...

Page 6: ...n 2 5 2 Magnetic field 2 5 3 Installation of converter Mount converter with mounting plate on wall or standpipe Keep distance between sensor and signal converter as short as possible Observe length of the delivered signal cable Figure 2 3 Vibration Figure 2 4 Magnetic field INFORMATION Only applicable for remote versions ...

Page 7: ...plate DANGER Observe the national regulations for electrical installations WARNING Observe without fail the local occupational health and safety regulations Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists INFORMATION Look at the device nameplate to ensure that the device is delivered according to your order Check for the co...

Page 8: ...oning always use the signal cables included in the delivery INFORMATION You only receive a signal cable if you ordered a remote version INFORMATION The signal cable is only used with remote versions The standard WSC cable includes both electrode and field current leads the optional type A B cable is only used for the electrodes In that case the field current cable is no part of the supply Figure 3...

Page 9: ...Put the cover back Tighten the 4 Allen bolts Put the blue protection cap back CAUTION Please connect battery before first use see relevant chapter for your type of battery Each converter is always delivered with a disconnected battery Figure 4 1 Connecting battery WARNING Make sure that the battery cable is not jammed by the cover INFORMATION The instrument now operates with factory set parameters...

Page 10: ...ount the attached cable gland loosely Pull the cable to the top of the electronics Fasten the battery connector to the internal connector in the converter Check that the display lights up Refit the metal strip at the bottom of the housing Tighten the cable gland Put the cover back Tighten the 4 Allen bolts Put the blue protection cap back WARNING Make sure that the battery cable is not jammed by t...

Page 11: ...NOTES 5 11 IFC 070 www krohne com 11 2010 7311222400 QS IFC 070 R04 en ...

Page 12: ...lysis products Measuring systems for the oil and gas industry Measuring systems for sea going tankers Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 D 47058 Duisburg Germany Tel 49 0 203 301 0 Fax 49 0 203 301 10389 info krohne de KROHNE 11 2010 7311222400 QS IFC 070 R04 en Subject to change without notice The current list of all KROHNE contacts and addresses can be found at www krohne co...

Reviews: