Item 

#

Description

Part #

Qty.

1

BURNER TUBE 1 1/2" - 50

240005543

1

BURNER TUBE 1 1/2" - 75, 100

2

BURNER TUBE 1 1/2" - 125, 150

3

BURNER TUBE 1 1/2" - 175, 200

4

BURNER TUBE 1 1/2" - 250

5

BURNER TUBE 1 1/2" - 300

6

2

BASE W/INSUL - 50

5611601

1

BASE W/INSUL - 75, 100

5611602

BASE W/INSUL - 125, 150

3001823

BASE W/INSUL - 175, 200

5611604

BASE W/INSUL - 250

5611605

BASE W/INSUL - 300

5611606

3

BURNER DOOR - 50

3261201

1

BURNER DOOR - 75, 100

3262701

BURNER DOOR - 125, 150

109008513

BURNER DOOR - 175, 200

109008514

BURNER DOOR - 250

109008515

BURNER DOOR - 300

109008516

4

MANIFOLD - 50

356-2-1.01

1

MANIFOLD - 75&100

356-2-1.02

MANIFOLD - 125&150

356-2-1.03

MANIFOLD - 175&200

356-2-1.04

MANIFOLD - 250

356-2-1.05

MANIFOLD - 300

356-2-1.06

Item 

#

Description

Part #

Qty.

5

SCREW ¼ - 20 X ½ SELF TAP

HW-005.01

4

6

GAS VALVE VR8200H - 50 - 150 24V NAT

VG-003.05

1

GAS VALVE VR8200H -  50 - 300 24V LP

VG00307

GAS VALVE VR8204H - 50 - 150 SPARK NAT

VG01101

GAS VALVE VR8304H4 - 175-300 SPARK NAT

VG01103

GAS VALVE VR8304 - 50-300 SPARK LP

VG01104

GAS VALVE VR8300H4 - 250 & 300 24V NAT

VG01201

GAS VALVE VR8300H4 - 175 & 200 24V NAT

VG01202

7

ORIFICE 3.2mm NAT -  50, 100, 150, 200, 250, & 300

240007406

*

ORIFICE 3.0mm NAT - 175

240007404

ORIFICE 2.9mm NAT -  125

240007403

ORIFICE 2.8mm NAT - 75

240007402

ORIFICE #45 LP - 50

3551520

ORIFICE #47 LP - 100, 150, 200, 250, & 300

355-1-5.04

ORIFICE #49 LP - 125 & 175

355-1-5.06

ORIFICE #50 LP - 75

355-1-5.07

NOT

 SHOWN

COMBUSTIBLE BASE FLOORING - 50

325-2-8.01

1

COMBUSTIBLE BASE FLOORING - 75, 100

325-2-8.02

COMBUSTIBLE BASE FLOORING - 125, 150

325-2-8.03

COMBUSTIBLE BASE FLOORING - 175, 200

325-2-8.04

COMBUSTIBLE BASE FLOORING - 250

325-2-8.05

COMBUSTIBLE BASE FLOORING - 300

325-2-8.06

*

 Orifi ce Quantities: Model 50 - qty 1; Model 75 & 100- qty 2; Model 125 & 150- 

qty 3; Model 175 & 200- qty 4; Model 250- qty 5; Model 300- qty 6.

REPLACEMENT PARTS - BASE

BOILER BASE

Содержание Olsen OMGB Series

Страница 1: ... SERIES Cast Iron Gas Fired Boilers For Forced Hot Water INSTALLATION OPERATION MAINTENANCE MANUAL MODEL NUMBERS OMGB50 OMGB75 OMGB100 OMGB125 OMGB150 OMGB175 OMGB200 OMGB250 OMGB300 ECR International 2201 Dwyer Avenue Utica New York 13501 USA www ecrinternational com ...

Страница 2: ...ious injury CAUTION Indicates a hazardous situation which if not avoided may result in minor or moderate injury NOTICE Indicates information which should be followed to ensure proper installation and operation WARNING Keep boiler area clear and free from combustible materials gasoline and other flammable vapors and liquids DO NOT obstruct air openings to the boiler room Modification substitution o...

Страница 3: ...a level Canada 2000 ft 610m to 4500 1350m above sea level Reduce input per table Canada over 4500 ft 1350m above sea level Contact Provincial authority having jurisdiction 2 Net I B R Water Ratings shown based on piping and pickup allowance of 1 15 Consult manufacturer before selecting boiler for installations having unusual piping and pickup requirements such as intermittent system operation exte...

Страница 4: ...pply Return Tappings A B C D E F 50 11 5 4 30 36 6 1 75 15 7 5 30 37 6 1 100 15 7 6 30 37 6 1 125 18 9 6 30 37 6 1 150 18 9 7 30 37 7 1 175 22 11 7 30 38 7 1 200 22 11 8 30 38 8 1 250 26 13 16 13 8 30 40 8 1 300 30 15 9 30 42 10 1 Propane gas inlet all units 1 2 DIMENSIONS ...

Страница 5: ... replacement condensate trap control replacement etc Locate boiler on level solid base as near the chimney 6 as possible and centrally located with respect to the heat distribution system as practical Allow 24 inches 610mm at front and right side for 7 servicing and cleaning When installed in utility room door should be wide 8 enough to allow largest boiler part to enter or to permit replacement o...

Страница 6: ...th outdoors Two Permanent Opening Method Provide opening о commencing within 12 inches of top and second opening commencing within 12 inches of bottom enclosure Direct communication with outdoors or communicating through vertical ducts Provide minimum free area of 1 in2 per 4 Mbh of total input rating of all appliances in enclosure Communicating through horizontal ducts Provide minimum free area o...

Страница 7: ... plug or place any obstruction in discharge line terminate freely to atmosphere where any discharge will be clearly visible and at no risk of freezing allow complete drainage of the valve and the discharge line be independently supported and securely anchored to avoid applied stress on the relief valve be as short and straight as possible terminate with plain end not threaded be constructed of mat...

Страница 8: ...irculator must be supplied with a flow control valve to prevent gravity circulation Hot water boilers and system must be filled with water 5 and maintained to a minimum pressure of 12 psi Bypass piping is an option which gives the ability to 6 adjust the supply boiler water temperature to fit the system or the condition of the installation This method of piping however is not typically required fo...

Страница 9: ...iping shall be independent of other discharge piping Size and arrange discharge piping to avoid reducing safety relief valve relieving capacity below minimum relief valve capacity stated on rating plate Run pipe as short and straight as possible to location protecting user from scalding and properly drain piping Install union if used close to safety relief valve outlet Install elbow s if used clos...

Страница 10: ...VALVE HOSE BIB FLOW CONTROL VALVE EXPANSION TANK BOILER DHW CIRCULATOR CH CIRCULATOR PRIORITY ZONE CIRCULATOR EXPANSION TANK WATER INLET FLOW CONTROL VAVLE SHUT OFF VALVE PRESSURE REDUCER VALVE CHECK VALVE BALL VALVE AIR SEPARATOR ZONE VALVE HOSE BIB CONNECTING SUPPLY AND RETURN PIPING Figure 8 Single Zone System With DHW Priority Figure 9 Multi Zone System With Circulators And DHW Priority ...

Страница 11: ...RIORITY ZONE BOILER WATER INLET CH DHW SYSTEM CIRCULATOR USE FULL PORT ZONE VALVE FOR OPTIMUM TANK PERFORMANCE CONSIDER USING ZONE CIRCULATOR SEE FIGURE 5 ZONE 4 CIRCULATOR SHUT OFF VALVE PRESSURE REDUCER VALVE CHECK VALVE EXPANSION TANK AIR SEPARATOR ZONE VALVE HOSE BIB FLOW CONTROL VALVE CONNECTING SUPPLY AND RETURN PIPING Figure 10 Multi Zone System With Zone Valves And DHW Priority With Circul...

Страница 12: ...ING This boiler shall not be connected to any portion of a mechanical draft system operating under positive pressure VENT SYSTEM MODIFICATION REMOVAL OF BOILER FROM VENTING SYSTEM At the time of removal of an existing boiler the following steps shall be followed with each appliance remaining connected to the common venting system placed in operation while the other appliances remaining connected t...

Страница 13: ...NS Verify only boiler is serviced by Vent Damper 1 Figure 13 Clearance of not less than 6 inches 152mm between 2 Vent Damper and combustible material must be maintained Additional clearance should be allowed for service of Vent Damper Vent Damper must be in the open position when 3 appliance main burners are operating The Vent Damper position indicator must be in a visible 4 location following ins...

Страница 14: ... serious injury Leak Check Gas Piping Pressure test boiler and gas connection before placing boiler in operation Pressure test over 1 2 psig 3 5 kPa Disconnect boiler and its individual gas shutoff valve from gas supply system Pressure test at 1 2 psig 3 5 kPa or less Isolate boiler from gas supply system by closing manual gas shutoff valve Locate leakage using gas detector noncorrosive detection ...

Страница 15: ...bove the floor NEVER install a thermostat on an outside wall 2 Do not install a thermostat where it will be affected 3 by drafts hot or cold pipes sunlight lighting fixtures televisions a fireplace or a chimney Check thermostat operation by raising and lowering 4 thermostat setting as required to start and stop the burners Instructions for the final adjustment of the thermostat 5 are packaged with...

Страница 16: ...16 VR8200 OR VR8300 WIRING DIAGRAM 24V STANDING PILOT ...

Страница 17: ...17 WIRING DIAGRAM INTERMITTENT IGNITION ...

Страница 18: ...on to the left 1 Set the thermostat to lowest setting 2 Turn off all electric power to the appliance 3 This appliance is equipped with an ignition device which 4 automatically lights the pilot Do not try to light the pilot by hand Figure 15 Intermittent Pilot Turn gas control knob clockwise 5 to OFF Wait 5 minutes to clear out any gas If you then smell 6 gas STOP Follow What To Do If You Smell Gas...

Страница 19: ...ontrol knobs cannot be turned from PILOT to OFF unless knob is pushed in slightly DO NOT FORCE Wait 5 minutes to clear out any gas If you then smell 6 gas STOP Follow What To Do If You Smell Gas on previous page If you don t smell gas go to the next step Find pilot Follow metal tube from gas control Depend 7 ing on the model of the boiler pilot is either mounted on the base or on one of the burner...

Страница 20: ...ators need to be checked and maintained Refer to the circulator manufacturer s instructions The venting system should be inspected at the start of each heating season Check the vent pipe from the boiler to the chimney for signs of deterioration by rust or sagging joints Repair if necessary Remove the vent pipe at the base of the chimney or flue and using a mirror check vent for obstruction and mak...

Страница 21: ... clockwise to decrease pilot flame Be sure to replace cover screw after adjustment to prevent possible gas leakage Figures 15 17 on previous pages The burners and pilot should be checked for signs of corrosion rust or scale buildup The area around the boiler must be kept clear and free of combustible materials gasoline and other flammable vapors and liquids The free flow of combustion and ventilat...

Страница 22: ...minus 0 3 inches water column from the specified pressure Primary air adjustment is not necessary therefore air shutters are not furnished as standard equipment Air shutters can be furnished on request where required by local codes or conditions CHECK SAFETY CONTROL CIRCUIT Ignition system safety shutoff device must be tested after placing boiler in operation Figures 15 17 on previous pages 1 Pilo...

Страница 23: ...50 24V NAT VG 003 05 1 GAS VALVE VR8200H 50 300 24V LP VG00307 GAS VALVE VR8204H 50 150 SPARK NAT VG01101 GAS VALVE VR8304H4 175 300 SPARK NAT VG01103 GAS VALVE VR8304 50 300 SPARK LP VG01104 GAS VALVE VR8300H4 250 300 24V NAT VG01201 GAS VALVE VR8300H4 175 200 24V NAT VG01202 7 ORIFICE3 2mmNAT 50 100 150 200 250 300 240007406 ORIFICE 3 0mm NAT 175 240007404 ORIFICE 2 9mm NAT 125 240007403 ORIFICE...

Страница 24: ...Exchanger 7 Section ROLLOUT SPILL SWITCH Item Description Part Qty 1 2 SECTION TEMP SENSOR BRACKET 32611001 1 3 SECTION TEMP SENSOR BRACKET 3262001 1 4 SECTION TEMP SENSOR BRACKET 109008517 1 5 7 SECTION TEMP SENSOR BRACKET 109008518 1 2 CONTROL FIXEDTEMPERATURETHERMO ROLLOUT SWITCH AQ02101 1 3 SCREW 6 X HEX HD HW06501 2 Rollout switch is located on base and flue collector NOTE Quantities above ar...

Страница 25: ...NEL BASE 125 150 109008530 PANEL BASE 175 200 109008531 PANEL BASE 250 109008532 PANEL BASE 300 109008533 Item DESCRIPTION Part Number Qty 6 PANEL RIGHT 50 200 3162705 1 PANEL RIGHT 225 300 3162703 7 PANEL REAR 50 3162601 1 PANEL REAR 75 100 3162602 PANEL REAR 125 150 3162603 PANEL REAR 175 200 3162604 PANEL REAR 250 3162605 PANEL REAR 300 3162606 8 FLUE COL 50 3462101 1 FLUE COL 75 3462108 FLUE C...

Страница 26: ... 6 Pilot Shield 1 Included with 3 Pilot Tube Assembly Kit above Continuous Pilot Kit Natural Gas 550001926 Continuous Pilot Kit LP Propane 550001927 Item Description Qty 1 PILOT BRACKET ASSEMBLY 1 2 BRACKET SCREW 2 3 THERMOCOUPLE Q309 1 4 PILOT TUBING 1 8 x 24 1 5 Natural Gas Q314A PILOT 1 LP Q314A Pilot Included with 3 Pilot Tube Assembly Kit above 1 5 3 4 2 REPLACEMENT PARTS PILOT 1 5 4 2 3 6 ST...

Страница 27: ...E 1 1 4X3 4X1 1 4 PF 008 03 1 7 PIPE 1 1 4 CLOSE NPL PF 006 01 1 8 WIRE LOW VOLTAGE DAMPER 375 1 14 01 1 9 HARNESS CIRCULATOR 72 37519501 1 10 CONTROL L8148E1257 AQUASTAT 1010002 1 11 RELIEF VALVE 30 VR 001 01 1 12 WELL 3 4 X3 AQ 020 01 1 13 GAUGE THERALTIMETER GA 001 00 1 14 PIPE NPL 3 4 X4 PF 005 11 1 15 PIPE ELBOW 3 4 90 PF 002 04 1 16 CLAMP 3600 WHITE EF03601 2 17 PLT SPARK CTRL S8600 PB00604 ...

Страница 28: ...ECR International 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com ...

Отзывы: