28141 Rev A 10-27-06
14
TABLE A-7: RIELLO 40BF OIL BURNER SET-UP FOR SIDE WALL VENTED BCL(S) AND
BFL
Riello Balanced Flue Series Oil Burners
(for use with sidewall vented units using outdoor combustion air)
Furnace Model
Burner Model
Nozzle
Pump Pressure
Flow Rate
Turbulator
Setting
BCL-80(S) RBU
40BF-3
0.60 / 60°W
120
PSIG
0.65
USGPH
0.5
BCL-90(S) RBU
40BF-3
0.65 / 60°W
135
PSIG
0.75
USGPH
1.0
BCL-100(S) RBU
40BF-3
0.75 / 60°W
130
PSIG
0.85
USGPH
0.0
BCL-120(S) RBU
40BF-5
0.85 / 60°W
140
PSIG
1.00
USGPH
1.5
BFL-80 RBU
40BF-3
0.60 / 60°W
120
PSIG
0.65
USGPH
0.5
BFL-90 RBU
40BF-3
0.65 / 60°W
135
PSIG
0.75
USGPH
1.0
BFL-100 RBU
40BF-3
0.75 / 60°W
130
PSIG
0.85
USGPH
0.0
BFL-120 RBU
40BF-5
0.85 / 60°W
140
PSIG
1.00
USGPH
1.5
A.1 OIL BURNER AIR ADJUSTMENT
For complete details, consult the oil burner
instruction manual provided in the furnace
documents envelope.
Beckett AF Burner
Adjust the air shutter by loosening the lock screws
and moving the air shutter, and if necessary, the
bulk air band.
Aero HFUS Burner
Adjust the air band by loosening the lock screw
and moving the air band.
Beckett AFII Burner
Adjust the burner air supply by first loosening the
locking screw located on the black dial to the right
of the burner. Turn the black dial clockwise to
increase the combustion air and counter-clockwise
to decrease the combustion air. Re-tighten the
locking screw after obtaining the proper setting.
Riello 40 Series (Chimney Vented)
Riello burners are factory set with respect to pump
pressure, air gate and turbulator adjustments,
each model and firing rate must be adjusted
accordingly, see Appendix A, Tables A-4 to A-6
.
The combustion air can be adjusted by first
removing the burner cover and loosening the fixing
screws that secures the air adjustment plate.
Move the adjusting plate to either increase or
decrease combustion air. When the proper air
setting is achieved, retighten the fixing screws.
Riello R35 Series
Riello burners are factory set with respect to pump
pressure, air gate and turbulator adjustments,
each model and firing rate must be adjusted
accordingly, see Appendix A, Tables A-4 to A-6
.
Riello Balanced Flue (BF) Series
Riello burners are factory set with respect to pump
pressure, air gate and turbulator adjustments,
each model and firing rate must be adjusted
accordingly, see Appendix A, Tables A-4 to A-6
.
The combustion air can be adjusted with the
burner cover on by first removing the plastic cover
on the top right hand side of the burner cover.
With a Philips head screw driver, turn the
adjustment screw clockwise to increase
combustion air or counter-clockwise to decrease
combustion air. When the combustion air is set,
re-insert the plastic cover.
Wayne HSR Burner
Adjust the burner air supply by loosening the
screw on the indicator located near the bottom left
side of the burner. Turn clockwise to increase or
counter clockwise to decrease the amount of air
required for combustion. Tighten the screw after
finishing with adjustments.
Содержание BCL
Страница 23: ...28141 Rev A 10 27 06 23 TABLE B 1 BECKETT AND RIELLO CHIMNEY VENTED WIRING DIAGRAM BCL S BFL ...
Страница 24: ...28141 Rev A 10 27 06 24 TABLE B 2 BECKETT AND RIELLO DIRECT VENT WIRING DIAGRAM BCL S BFL ...
Страница 29: ...29809 Rev A 10 19 2006 29 ...
Страница 32: ...29809 Rev A 10 19 2006 32 ...
Страница 36: ...29809 Rev A 10 19 2006 36 ...
Страница 41: ...28141 Rev A 10 27 06 NOTES ...
Страница 42: ...28141 Rev A 10 27 06 ...
Страница 43: ...28141 Rev A 10 27 06 ...