background image

9

EDES

DEHUMIDIFIER

Continuous draining

Water can be automatically emptied into a floor drain by 

attaching the unit with a water hose (Id≤Ø5/16",not included))

with a female threaded end (ID:M=1", not included).

Install the drain hose onto the adaptor A (See Fig. 7, placed in 

the bucket).

Remove the plastic cover from the back drain outlet of the unit 

and set aside and remove bucket, then insert the drain hose 

through the drain outlet of the unit and securely press it into 

the connector on the front of the unit. (See Fig. 9)

Tighten the adaptor A and the unit by using two screws (Placed 

in the bucket).

Install the female threaded end of the water hose into the 

adaptor A. (See Fig. 10), then lead the water hose to the floor 

drain or a suitable drainage facility.

Make sure the hose is secure so there are no leaks.

Direct the hose toward the drain, making sure that there are no 

kinks that will stop the warter flowing.

Place the end of the hose into the drain and make sure the end 

of the hose is leveled or down to let the water flow smoothly. 

Place the bucket back in the unit and make sure that it is 

positioned correctly.

Select the desired humidity setting and fan speed on the unit 

for continuous draining to start.

2

OPERATING THE UNIT

REMOVING THE COLLECTED WATER

1

When the water in the bucket reaches a certain level, please be 

careful to move the machine to avoid it falling down.

NOTE

NOTE

There are two ways to remove collected water.

Use the bucket

When the unit is off, if the bucket is full, the unit will beep 8 

times and the Full indicator light will flash, the digital display 

shows P2.

When the unit is on, if the bucket is full, the compressor turns 

off and the fan turns off after 30 seconds to dry the water of the 

condenser, then the unit will beep 8 times and the Full indicator 

light will flash, the digital display shows P2.

Slowly pull out the bucket. Grip the left and right handles 

securely, and carefully pull out straight so water does not spill. 

Do not put the tank on the floor because the bottom of the 

bucket is uneven. The bucket will fall and cause the water to 

spill.

Throw away the water and replace the bucket. The bucket must 

be in place and securely seated for the dehumidifier to operate.

The machine will re-start when the bucket is restored in its 

correct position.

When you remove the bucket, do not touch any parts inside of the 

unit. Doing so may damage the product.

Be sure to push the bucket gently all the way into the unit. Banging 

the bucket against anything or failing to push it in securely may 

cause the unit not to operate.

When you remove the bucket, if there is some water in the unit you 

must dry it .

FIG. 6

FIG. 7

FIG. 8

FIG. 5

Содержание EDES

Страница 1: ...EDES EDES OWNER S MANUAL DEHUMIDIFIER Thank you for purchasing this ecox product Before using this machine please read this manual and retain it for future reference ...

Страница 2: ...y children without supervision This appliance is not intended for use by persons Including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If...

Страница 3: ...are several possibilities The municipality has established collection systems where electronic waste can be disposed of charge to the user When buying a new product the retailer will take back the old product free of charge The manufacture will take back the old appliance for disposal free of charge to the user As old products contain valuable resources they can be sold to scrap metal dealers Wild...

Страница 4: ... sounds smell or smoke comes out of the unit It may cause fire and electric shock Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc It may cause an explosion or fire Do not operate or stop the unit by switching on or off the main power source Itmaycauseelectricshockorfireduetoheatgeneration Do not insert or pull out plug with wet hands It may cause elec...

Страница 5: ...t may cause failure of appliance or accident Do not use in areas where chemicals are handled This will cause the units deterioration due to chemicals and solvents dissolved in the air Do not climb up or sit on the unit You may be injured if you fall or if the unit falls over Do not place flower vases or other water containers on top of the unit Watermayspillinsidetheunit causinginsulationfailure a...

Страница 6: ...l the fan speed Press to select either High or Normal fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal Power Pad Press to turn the dehumidifier on and off Humidity Set Control Pads The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH Relative Humidity in 5...

Страница 7: ... automatically For some models the fan motor will continue operating Auto Defrost When frost builds up on the evaporator coils the compressor will cycleoffandthefanwillcontinuetorununtilthefrostdisappears Wait 3 minutes before resuming operation After the unit has stopped it can not be restarted in the first 3 minutes This is to protect the unit Operation will automatically start after 3 minutes C...

Страница 8: ...Select a suitable location making sure you have easy access to an electrical outlet Plug the unit into a electrical socket outlet with ground connection Make sure theWater bucket is correctly fitted otherwise the unit will not operate properly IDENTIFICATION OF PARTS FRONT ACCESSORIES POSITIONING THE UNIT BACK 1 1 3 3 5 2 2 4 4 6 Control panel Air intake grille Air outlet grille Air filter behind ...

Страница 9: ...T REMOVING THE COLLECTED WATER 1 When the water in the bucket reaches a certain level please be careful to move the machine to avoid it falling down NOTE NOTE There are two ways to remove collected water Use the bucket When the unit is off if the bucket is full the unit will beep 8 times and the Full indicator light will flash the digital display shows P2 When the unit is on if the bucket is full ...

Страница 10: ...tinuous drain feature is not being used remove the drain hose from the outlet CARE AND CLEANING OF THE DEHUMIDIFIER Turn the dehumidifier off and remove the plug from the wall outlet before cleaning Clean the Grille and Case Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock cause the insulation to de...

Страница 11: ...fier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5ºC 41ºF There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The air filter is clogged The unit is tilted instead of upright as it should be The floor surface is not leveld Frost a...

Страница 12: ......

Отзывы: