Continuous draining
Water can be automatically emptied into a floor drain by
attaching the unit with a water hose (Id≤Ø5/16",not included))
with a female threaded end (ID:M=1", not included).
Install the drain hose onto the adaptor A (See Fig. 7, placed in
the bucket).
Remove the plastic cover from the back drain outlet of the unit
and set aside and remove bucket, then insert the drain hose
through the drain outlet of the unit and securely press it into
the connector on the front of the unit. (See Fig. 9)
Tighten the adaptor A and the unit by using two screws (Placed
in the bucket).
Install the female threaded end of the water hose into the
adaptor A. (See Fig. 10), then lead the water hose to the floor
drain or a suitable drainage facility.
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain, making sure that there are no
kinks that will stop the warter flowing.
Place the end of the hose into the drain and make sure the end
of the hose is leveled or down to let the water flow smoothly.
Place the bucket back in the unit and make sure that it is
positioned correctly.
Select the desired humidity setting and fan speed on the unit
for continuous draining to start.
2
OPERATING THE UNIT
REMOVING THE COLLECTED WATER
1
When the water in the bucket reaches a certain level, please be
careful to move the machine to avoid it falling down.
NOTE
NOTE
There are two ways to remove collected water.
Use the bucket
When the unit is off, if the bucket is full, the unit will beep 8
times and the Full indicator light will flash, the digital display
shows P2.
When the unit is on, if the bucket is full, the compressor turns
off and the fan turns off after 30 seconds to dry the water of the
condenser, then the unit will beep 8 times and the Full indicator
light will flash, the digital display shows P2.
Slowly pull out the bucket. Grip the left and right handles
securely, and carefully pull out straight so water does not spill.
Do not put the tank on the floor because the bottom of the
bucket is uneven. The bucket will fall and cause the water to
spill.
Throw away the water and replace the bucket. The bucket must
be in place and securely seated for the dehumidifier to operate.
The machine will re-start when the bucket is restored in its
correct position.
When you remove the bucket, do not touch any parts inside of the
unit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the unit. Banging
the bucket against anything or failing to push it in securely may
cause the unit not to operate.
When you remove the bucket, if there is some water in the unit you
must dry it .