DEHUMIDIFIER
Setting the Timer
When the unit is on, first press the Timer button, the Timer Off
indicator light illuminates. It indicates the Auto Stop program is
initiated. Press it again the Time On indecator light illuminates.
It indicates the Auto Start is initiated.
When the unit is off, first press the Timer button, the TIMER ON
indicator light illuminates. It indicates the Auto Start program is
initiated. Press it again the Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to change the Auto time by
0.5 hour increments, up to 10 hours, then at 1 hour increments
up to 24 hours. The control will count down the time remaining
until start.
The selected time will register in 5 seconds and the system
will automatically revert back to display the previous humidity
setting.
When the Auto start & Auto stop times are set, within the same
program sequence, TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are now programmed.
Turning the unit ON or OFF at any time or adjusting the timer
setting to 0.0 will cancel the Auto Start/Stop function.
When LED display window displays the code of P2, the Auto
Start/Stop function will also be cancelled.
Bucket Full Light
Glows when the bucket is ready to be emptied, or when the
bucket is removed or not replaced in the proper position.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when the bucket
is full, or when the bucket is removed or not replaced in the
proper position. When the setting humidity is reached, the unit
will be shut off automatically. For some models, the fan motor
will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restarted in the first 3
minutes. This is to protect the unit. Operation will automatically
start after 3 minutes.
Check filter feature
The system starts to count the time once the fan motor
operates. The check filter feature will be activated when the
accumulated operation hours reaches 250 or more. The Reset
light (Clean filter indicator light) flashes at one time per second,
after cleaning and replacing the air filter, press the Filter pad
and the Reset light (Clean filter indicator light) goes off.
Auto-Restart
If the unit turns off unexpectedly due to the power cut, it will
restart with the previous function setting automatically when
the power resumes.
OTHER FEATURES
Display
Shows the set % humidity level from 35% to 85% or auto start/
stop time (0~24) while setting, then shows the actual (± 5%
accuracy) room % humidity level in a range of RH (Relative
Humidity) to 90%RH (Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back in.
If error repeats, call for service.
ES- Temperature sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position--Empty the
bucket and replace it in the right position.
EC- Unit malfuction-Please make sure whether the enviroment
temperature is suitable for the stated temperature in the
manual. If not, please operate the unit under the stated
temperature. If the enviroment temperature is suitable for the
stated temperature, please call service.