2. if the stove goes out during operation:

•  check all the possibilities in previous section.
•  check whether the stove is ready for programmed cleaning after 2500 hours have ex-

pired. the display will show 

cleaning/maintenance

 message.

•  make sure that the thermal safety switch (re-settable manually), on the inside back right 

of the stove, has been reset.

  remark: on all LADy models the switch is located underneath the stove left-hand side.
•  before resetting the switch find the reason for its triggering.
 

Note that the thermal switch can only be reset with electrical supply off and when the stove 
temperature has fallen below 93°C.

poWEr FaiLurE

Brief power failure:

 if there is a brief power failure (60 seconds), when the stove is at the 

ignition stage or is operating normally, the stove is programmed to re-ignite itself. if the 
power failure lasts for a longer, indefinite period, when the power returns the stove will go 
into an extinguishing cycle, setting up for the next (manual or programmed) ignition. in this 
case the display will show 

Black-out

 message.

to reset the stove functions, switch it 

ON-OFF

.  

temporary power failure:

 if there is a power failure lasting 3÷5 minutes, with direct flue 

gas exhaust pipes the stove may emit some smoke into the room, produced by the unburnt 
pellets present in the grate. 
this does not constitute a safety risk. the problem can be avoided by installing the exhaust 
pipe as shown on this handbook. 

Electrical safety:

 the stove is protected against power surges by two fuses on the elec-

tronics board.

Содержание Lady

Страница 1: ... used 4 Important instructions before ingnition 4 Recommendations for using the stove correctly 5 Installation 6 Combustion air inlet 7 Operation 8 Maintenance 10 Ordinary maintenance 10 Extraordinary maintenance 10 Mainenance of the smoke exhaust duct 11 Operating problems and solutions 12 Declaration of conformity 15 Guarantee 16 programming instructions PRETTY Pretty Cer NICE Nice Cer Lady Lady...

Страница 2: ...ated as efficiently as possible and in complete safety The device must be installed correctly for safety reasons and to ensure proper operation The stove should never be used by people who do not know how to work it Keep children and animals away from the stove when it is in use This handbook has been written by the manufacturer and is an integral part of the product The information it contains is...

Страница 3: ...ossible we recommend installing a T pipe for inspection at the stove exhaust gas outlet in order to recover the burnt microdust and also a steel pipe two metres high to be connected to the existing flue in order to discharge the flue gas This device will prevent smoke formation inside the rooms should there be a power failure for any reason during stove operation STANDARD EQUIPMENT User s and inst...

Страница 4: ... pressed wood It is very important to choose a clean top quality pellet without impurities For the stove to work properly and safely it is necessary to use pellets that comply with the following standards DIN 51731 and ONORM M 7135 thermal value residual humidity diameter quality of wood used Ecowood cannot assume liability for poor operation of the stove if poor quality pellets are used Use only ...

Страница 5: ... as to prevent the risk of burns or scalds or breakage or cracking of the glass itself Use special products for cleaning glass and the body work Take care not to knock against the stove as this could cause permanent damage If the glass is cracked or broken do not attempt to light the stove Do not open the door of the hearth when the stove is lit Always follow these instructions precisely when ligh...

Страница 6: ...l insulate the material with suitable fireproof or fire resistant products Connect the flue pipe of your stove to an existing chimney or alternatively install a fume exhaust pipe outside the building The pipe must have a minimum pipe diameter of 80 mm and reach higher than the top of the roof If the stove is installed in a building with poten tially inflammable walls it will be necessary to place ...

Страница 7: ...ET In order to guarantee good combustion the stove must receive enough air to ensure the fuel receives sufficient oxygen Connect the combustion air inlet to the outside so that it cannot be obstructed even partially in any way If the stove cannot be connected directly to the outside it is possible to install a permanent ventilation grating this will guarantee perfect combustion and hence lower pel...

Страница 8: ... exclusively by the installer Is not possible to change the direction of the flue gas outlet on the stove with majolica covering NICE CER OPERATION After installing the stove as described above fill the tank on top of the stove with the pellets through the door on the stove The tank should always contain enough fuel to guarantee a regular supply to the stove and the door should be closed during op...

Страница 9: ...fety therefore an automatic power limiting device has been installed as standard in the stove If the automatic power limiting device is disabled at the user s request this should be done by the installer technician following an evaluation of the conditions under which the stove is to be used it is necessary to connect the stove to the flue gas exhaust system using stainless steel pipes or pipes pa...

Страница 10: ...aning Remove the panel fastened down with four screws and clean it carefully using a vacuum cleaner to suck out the dust deposited inside the exhaust flue and the ash box Take out the flue exhauster motor and clean the screw carefully Re assemble all the parts in the reverse order oiling the screws After carefully carrying out all necessary checks the automatic stove operation block ing device sho...

Страница 11: ...r regulating both the exhaust pressure and pellet loading rate This should be carried out only by the installer technician at installation or when conditions make it necessary 2 A vertical metal exhaust pipe that is three four metres long will increase the combus tion rate This will cause the stove to go out at the minimum power level To prevent this just increase the selected power level or chang...

Страница 12: ... it is not working make sure that it is pow ered if there is power and it turns slowly replace it with a new one if the flue exhauster motor stops the electronic board will immediately stop to feeding the pellet The screw motor is working properly If it is not working make sure that it is powered if there is power and it does not turn replace it with a new one if the motor reducer stops the stove ...

Страница 13: ...er failure if there is a brief power failure 60 seconds when the stove is at the ignition stage or is operating normally the stove is programmed to re ignite itself If the power failure lasts for a longer indefinite period when the power returns the stove will go into an extinguishing cycle setting up for the next manual or programmed ignition In this case the display will show Black Out message T...

Страница 14: ...d up Cause The brazier is dirty or not properly in place No pellets The element does not work CONTACT THE TECHNICIAN Vacuometer alarm Problem Trouble discharging the gases Cause The flue system is obstructed CONTACT THE TECHNICIAN Alarm overheating gas Problem The temperature of the discharge gases has exceeded the permitted threshold Cause The gear motor is operating continuously the gas probe is...

Страница 15: ...place of issue _ _____________________________________________________________________________ Name and signature of authorised person ______________________________________________________________ Position in firm ___________________________________________________________________________________ Potenza termica nominale 7 0 kW Potenza termica ridotta 2 9 kW nominale 0 028 Modello PRETTY NICE CO ...

Страница 16: ...rantee will this expire The guarantee does not cover the pellet loading auger gearbox the ignition resistance the glass and painted parts Other failures due to even partial lack of maintenance or incorrect installation The guarantee does not cover damage caused by transport It is therefore important to check the goods care fully on receipt and notify the retailer immediately if any damage is detec...

Отзывы: