background image

13

Electronic Controller (continued)

Program

Clean

LED blinking

red

every 8

sec. indicates
battery is low

“E E” in the
display indi-
cates battery
is low

4

. Place the connected battery into the clip provided

for it directly above the IN port (See Figure 18 on
Page 11).

5

. Slide the top cover back onto the ASF and push it

down to snap into place.

No reprogramming of the controller is necessary after
battery replacement or a power outage.

FIG. 23

Program

Clean

Two dashes
(not moving)
in the display
indicate auto-
matic flush is
turned off

SETTING THE NUMBER OF DAYS BE-
TWEEN AUTOMATIC SEDIMENT FLUSHES

The ASF controller is shipped with a default value of 7
days between automatic sediment flushes.  To change
the number of days (between 1 and 30) or to turn this
feature off:

1

. Press the PROGRAM button and hold it for at least

2 seconds.  When the LED turns on steadily with an
amber color, quickly release the PROGRAM button.

2

. While the amber LED is on (it goes off after 10 sec-

onds of button inactivity), repeatedly press the PRO-
GRAM button until the desired number of days
shows in the display.  Each press increases the
number of days by 1.  When the number passes 30,
it goes back to zero, indicated by “- -”, and counts
up from 1 again.

3

. Setting the number of days to “- -” (zero) turns off

the automatic flush feature.

4

. When the desired number of days shows in the dis-

play, wait 10 seconds (press no more buttons) for
the amber LED to go off.  The new number of days
is programmed.  This new setting will remain after
battery change or power loss.

TIME OF DAY WHEN FLUSH OCCURS

The time of day when the automatic sediment flush will
occur is the same time of day as when the most recent
of the following was done:

The filter was powered up

The number of days was set

A manual flush was initiated

If a different time of day is desired for automatic flush,
simply initiate a manual flush (as described on the pre-
vious page) at the desired time of day.

LOW BATTERY INDICATION

If the LED is blinking red every 8 seconds (and the 2-
digit display shows “E E“), then the battery needs to be
replaced.

BATTERY REPLACEMENT

1

. Remove the top cover from the ASF by sliding it

upward (See Figure 18 on Page 11).

2

. Locate the old battery and unsnap it from the bat-

tery connector.  Dispose of (recycle) old battery
properly.

3

. Take a new 9-volt battery and snap the battery con-

nector onto both terminals.

FIG. 22

Содержание EASF1

Страница 1: ...7301805 Rev A 3 12 08 EcoWater Systems LLC P O Box 64420 St Paul MN 55164 0420 How to install operate and maintain your EcoWater Systems Automatic Sediment Filter Model EASF1 OWNER S MANUAL...

Страница 2: ...ctrical and electronic equipment to be disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from re...

Страница 3: ...nt Filter is operated at water pressures not exceeding 100 psi and at water temperatures not exceeding 120 F provided further that the Automatic Sediment Filter is not subject to abuse misuse alterati...

Страница 4: ...d complete in one carton Remove all items from the shipping carton and check against the packing list below Packing List Filter Assembly Dimensions 5 1 4 15 4 1 8 10 FIG 2 Inlet Outlet 1 NPT threaded...

Страница 5: ...is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an electronic con...

Страница 6: ...le the faceplate may need to be reversed turned around to face the opposite direc tion so that it does not end up against a wall or other obstruction This can be done either before or after the filter...

Страница 7: ...of Massachusetts The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment...

Страница 8: ...compression fittings NOTE If your installation will use the mounting brack et position it correctly around the ASF before installing inlet and outlet fittings The bracket can not be put on after the i...

Страница 9: ...before installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully tur...

Страница 10: ...ose Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Страница 11: ...AC ADAPTOR not included An optional AC adaptor P N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 6 feet of wire One end plugs into...

Страница 12: ...t for at least 2 seconds When the 2 digit display changes to show moving dashes See Figure 20 release the CLEAN button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence ta...

Страница 13: ...display Each press increases the number of days by 1 When the number passes 30 it goes back to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic...

Страница 14: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...

Страница 15: ...sole noid seat requires cleaning use the following procedure 1 Before shutting off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main ho...

Страница 16: ...320 O Ring Valve 2 req 15 7301601 Battery 9 Volt 16 7298387 Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7...

Отзывы: