“unauthorised fuel” for use within a smoke control area unless it is used in an “exempt” appliance 

(“exempted” from the controls which generally apply in the smoke control area). 

 

In England appliances are exempted by publication on a list by the Secretary of State in accordance 

with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation 

Act 2015. Similarly, in Scotland appliances are exempted by publication on a list by Scottish Ministers 

under section 50 of the Regulatory Reform (Scotland) Act 2014. In Northern Ireland appliances are 

exempted by publication on a list by the Department of Agriculture, Environment and Rural Affairs 

under Section 16 of the Environmental Better regulation Act (Northern Ireland) 2016.  In Wales 

appliances are exempted by regulations made by Welsh Ministers.  

 

Further information on the requirements of the Clean Air Act can be found here: 

https://www.gov.uk/smoke-control-area-rules  

 

The Ecosy+ - Hampton 5 Large SE has been recommended as suitable for use in smoke control areas 

when burning seasoned wood logs. The appliance has a factory-fitted modification to the secondary air 

control to prevent closure beyond 4mm open position.  

 

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and 

supervision of smoke control areas and you can contact them for details of Clean Air Act requirements. 

Please note the following advice on minimising smoke emissions: 

Refuelling on to a low fire bed 

If there is insufficient burning material in the fire bed to light a new fuel charge, excessive smoke 

emission can occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and 

ash that the new fuel charge will ignite in a reasonable period. If there are too few embers in the fire 

bed, add suitable kindling to prevent excessive smoke.

 

Fuel overloading 

The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause 

excess smoke. 

Содержание Hampton 5 Large

Страница 1: ...Page 1 of 15 Hampton 5 Large...

Страница 2: ...ectly a house fire could result Installation must comply with relevant national and local Building Regulations and fire safety standards IN THE EVENT OF A CHIMNEY FIRE EVACUATE THE PROPERTY AND CALL T...

Страница 3: ...ilding Regulations and fire safety standards We would always suggest using a qualified installer to carry out the installation of this product The British recognised standard for solid fuel installati...

Страница 4: ...ct air feed socket The stove should be installed on a level floor with adequate load bearing capacity The stove does include adjustable feet for levelling Normally for most houses in the UK no extra v...

Страница 5: ...e installations easier and does not push the stove out as far as 90 degree T pieces The flue box cannot be used at the same time as the heat shield above Regulations All National and local regulations...

Страница 6: ...t can be found here https www gov uk smoke control area rules The Ecosy Hampton 5 Large SE has been recommended as suitable for use in smoke control areas when burning seasoned wood logs The appliance...

Страница 7: ...n you can buy a moisture meter which will indicate the moisture levels in your fuel Liquid fuels must NEVER be used WARNING Wet timber should not be used as this will create excess tar deposits in the...

Страница 8: ...such that the closure plate does not seal fully thus allowing some constant air supply into the stove This is a feature of all Defra SE stove When you light the fire you want this control fully open w...

Страница 9: ...obstruction Adequate ventilation and provision for combustion air has been made That the stove installation has been carried out in accordance with Building Regulations and any applicable local regula...

Страница 10: ...the stove whilst warm If the above advice is ignored then there is a high risk of the paint being shocked by excessive heat and could peel Furthermore if the stove is over fired it will invalidate yo...

Страница 11: ...mes are well established on the newly charged logs Always refuel onto hot embers If the fire has died out at the point of refuelling use kindling to re establish the fire and follow the Ignition proce...

Страница 12: ...ppliance to achieve good combustion When this happens the stove should not be used IMPORTANT As of October 2010 it is a legal requirement to use a Carbon Monoxide Detector in the same room as the stov...

Страница 13: ...de the baffle plate away but sometimes these are stiff and will bring the thread with it but should easily wind back in place Ensure the flat heat resistant fire rope seal is in good condition before...

Страница 14: ...l not be able to escalate your claim The guarantee will begin from the sale date on the invoice and we do not cover any cost incurred when removing faulty appliances or installing new ones even if it...

Страница 15: ...Page 15 of 15...

Отзывы: