![Ecosy+ Hampton 5 Large Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ecosy-0/hampton-5-large/hampton-5-large_manual_2355503006.webp)
Page 6 of 15
“unauthorised fuel” for use within a smoke control area unless it is used in an “exempt” appliance
(“exempted” from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance
with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation
Act 2015. Similarly, in Scotland appliances are exempted by publication on a list by Scottish Ministers
under section 50 of the Regulatory Reform (Scotland) Act 2014. In Northern Ireland appliances are
exempted by publication on a list by the Department of Agriculture, Environment and Rural Affairs
under Section 16 of the Environmental Better regulation Act (Northern Ireland) 2016. In Wales
appliances are exempted by regulations made by Welsh Ministers.
Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
The Ecosy+ - Hampton 5 Large SE has been recommended as suitable for use in smoke control areas
when burning seasoned wood logs. The appliance has a factory-fitted modification to the secondary air
control to prevent closure beyond 4mm open position.
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and
supervision of smoke control areas and you can contact them for details of Clean Air Act requirements.
Please note the following advice on minimising smoke emissions:
Refuelling on to a low fire bed
If there is insufficient burning material in the fire bed to light a new fuel charge, excessive smoke
emission can occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and
ash that the new fuel charge will ignite in a reasonable period. If there are too few embers in the fire
bed, add suitable kindling to prevent excessive smoke.
Fuel overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause
excess smoke.