RECOMMENDED SETTINGS FOR AURIGA 23KW 

 

0. Fuel ignition timeout --> [20]

 

36. Power 3 fan 2 speed --> [0]

 

73. User fuel feeder 1 ON time factor --> 
[100]

 

1. Ignition test timeout --> [10] 

37. Power 4 fan 2 speed --> [0] 

74. User fuel fan 1 speed factor --> [100] 

2. Fuel type --> [0] 

38. Power 5 fan 2 speed --> [0] 

75. Wood fuel fan 1 speed factor --> [100] 

3. Heat up feeder OFF time --> [210] 

39. Quickheat fan 2 speed --> [0] 

76. Selected configuration --> [1] 

4. Heat up feeder ON time --> [110] 

40. Stop fire fan 3 speed --> [240] 

77. 2nd room temperature --> [0.0] 

5. Fuel ignition feeder 1 OFF time --> 
[200] 

41. Test fire fan 3 speed --> [240] 

78. Flame ON level --> [0] 

6. Fuel ignition feeder 1 ON time --> [20] 

42. Heat up fan 3 speed --> [240] 

79. Flame OFF level --> [0] 

7. Ignition test feeder 1 OFF time --> 
[100] 

43. Fuel ignition fan 3 speed --> [240] 

80. Flame OFF detection delay --> [0] 

8. Ignition test feeder 1 ON time --> [10] 

44. Ignition test fan 3 speed --> [240] 

81. Underpressure setpoint --> [0] 

9. Power 1 feeder 1 OFF time --> [1] 

45. Power 1 fan 3 speed --> [240] 

82. Min. (error) underpressure/airflow --> 
[0] 

10. Power 1 feeder 1 ON time --> [13] 

46. Power 2 fan 3 speed --> [240] 

83. Underpressure/airflow error delay --> 
[0] 

11. Power 2 feeder 1 OFF time --> [1] 

47. Power 3 fan 3 speed --> [240] 

84. Accumulator temperature --> [0] 

12. Power 2 feeder 1 ON time --> [1] 

48. Power 4 fan 3 speed --> [240] 

85. T1-T2 for water pump OFF --> [0] 

13. Power 3 feeder 1 OFF time --> [1] 

49. Power 5 fan 3 speed --> [240] 

86. Boiler to accu. temperature drop --> 
[0] 

14. Power 3 feeder 1 ON time --> [1] 

50. Cool fluid exit temp. diff. --> [10] 

87. Keep fire fan 1 speed --> [0] 

15. Power 4 feeder 1 OFF time --> [1] 

51. Water/air temperature --> [38.0] 

88. Keep fire feeder 1 ON time --> [0] 

16. Power 4 feeder 1 ON time --> [1] 

52. Water temperature in stove mode --> 
[80] 

89. Keep fire fan 1 duration --> [0] 

17. Power 5 feeder 1 OFF time --> [1] 

53. Cool fluid entry temp. diff. --> [10] 

90. Keep fire period --> [0] 

18. Power 5 feeder 1 ON time --> [33] 

54. Ignition test gases temperature --> 
[80] 

91. Feeder 2 delay/ON time factor --> [0] 

19. Stop fire fan 1 speed --> [240] 

55. Modulation start gases temperature -
-> [320] 

92. Pellets quality --> [1] 

20. Test fire fan 1 speed --> [140] 

56. Heating device OFF gases 
temperature --> [75] 

93. Wood quality --> [1] 

21. Heat up fan 1 speed --> [150] 

57. Maximum (error) gases temperature -
-> [340] 

94. Time to service --> [0] 

22. Fuel ignition fan 1 speed --> [160] 

58. Fan 2 as ambient min. gases temp. --> 
[100] 

95. Stove cool fluid entry temp. diff. --> 
[5] 

23. Ignition test fan 1 speed --> [170] 

59. No fuel (error) gases temperature --> 
[60] 

96. Stove cool fluid exit temp. diff. --> [2] 

24. Power 1 fan 1 speed --> [150] 

60. Fan 1 blow cleaning period --> [60] 

97. T1-T2 for min. modul. speed --> [0] 

25. Power 2 fan 1 speed --> [0] 

61. Fan 1 blow cleaning duration --> [45] 

98. Full level --> [0] 

26. Power 3 fan 1 speed --> [0] 

62. Fan 1 blow cleaning speed --> [240] 

99. Low level --> [0] 

27. Power 4 fan 1 speed --> [0] 

63. Air pulse cleaning duration --> [0] 

100. Empty level --> [0] 

28. Power 5 fan 1 speed --> [200] 

64. Chamber cleaning duration/rot. --> 
[0] 

101. Blow out duration --> [180] 

29. Test fire fan 2 speed --> [0] 

65. Ash extraction auger duration --> [0] 

102. Antifreeze temperature --> [0] 

30. Stop fire fan 2 speed --> [0] 

66. Ash extraction auger period --> [0] 

103. Water pump minimum speed --> [0] 

31. Heat up fan 2 speed --> [0] 

67. ON temperature --> [40] 

104. Water pump maximum speed --> [0] 

32. Fuel ignition fan 2 speed --> [0] 

68. OFF temp./T1-T2 for 
max.modul.speed --> [35] 

105. Reserved 105 --> [0] 

33. Ignition test fan 2 speed --> [0] 

69. Anti-condensation exit temp. --> [0] 

73. User fuel feeder 1 ON time factor --> 
[100]

 

34. Power 1 fan 2 speed --> [0] 

70. Heat up duration --> [160] 

74. User fuel fan 1 speed factor --> [100] 

35. Power 2 fan 2 speed --> [0] 

71. Fuel ignition temp. check samples --> 
[6] 

75. Wood fuel fan 1 speed factor --> [100] 

0. Fuel ignition timeout --> [20]

 

72. Fuel ignition temperature rise --> [2] 

76. Selected configuration --> [1] 

 

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Содержание Auriga 23 kW

Страница 1: ...MANUAL for INSTALLATION and OPERATION of AURIGA 23 kW Downloaded from www Manualslib com manuals search engine...

Страница 2: ...3 6 INSTALLATION SCHEMES optional 9 3 7 REAR END OF THE EXHAUST GAS PIPE 10 3 8 CONNECTION TO THE ELECTRICAL POWER SUPPLY 10 4 0 USAGE 11 4 1 SAFETY PRECAUTIONS 11 4 2 FUELS 11 4 3 TECHNICAL SPECIFIC...

Страница 3: ...5 The Instruction manual is an inseparable part of the product In case the Instruction manual is missing or lost the end user should have it provided by the seller 6 This pellet stove should be used...

Страница 4: ...itial installation of the pellet stove you should check whether all accessories are in place Pipe scraping lever Remote controller Control panel screws for its mounting in the reservoir for pellets Do...

Страница 5: ...ecial metal sheet The inner part of the burner is coated with double metal sheet which guarantees higher thermal power of the pellet stove The burner has a door with ceramic glass which is heat resist...

Страница 6: ...h 1 5 Reservoir capacity Boiler capacity Kg Liters 30 35 Utilization at nominal thermal power 92 Nominal electrical power W 340 Nominal voltage V 230 Nominal frequency Hz 50 The above table is made on...

Страница 7: ...containing explosive materials The installation of the pellet stove should be made in accordance to all practical knowledge The space around the pellet stove should be made of stone cement or other fi...

Страница 8: ...s important to know that the exhaust system is as important as the pellet stove The installation of the exhaust system should be performed by authorized persons The authorized person should be guided...

Страница 9: ...e the same as that of the pellet stove the outer part should not be less than twice than the one of the pellet stove the manufacture should protect the system against rain snow and wind easy dissassem...

Страница 10: ...The connection should be easily accessible 4 0 USAGE 4 1 SAFETY PRECAUTIONS Taking into consideration that the pellet stove develops high temperature the young and adult persons should be careful and...

Страница 11: ...de either through the control panel or the software For normal operation of the stove it should be changed some parameters depend on the installation of the stove different type pellet length of the c...

Страница 12: ...try temp diff 10 90 Keep fire period 0 18 Power 5 feeder 1 ON time 33 54 Ignition test gases temperature 80 91 Feeder 2 delay ON time factor 0 19 Stop fire fan 1 speed 240 55 Modulation start gases te...

Страница 13: ...values for the currently selected menu option With buttons you can navigate through the menu and control the operation of the Fumis ALPHA controller Refer to the Table 1 Fumis ALPHA keyboard buttons o...

Страница 14: ...ected value blinks Enter button is used for entering the edit mode and confirming the set values or selecting the additional submenus Escape Cancel button is used for discarding the changes and return...

Страница 15: ...for modifying the settings is the same as in the second level menu To exit the edit mode without saving the changes press the Cancel button This button is also used for returning up one level in the...

Страница 16: ...urning power level value is shown on display For faster heating up to the desired room temperature you can increase the burning power setting In the Power context press the Enter button The display sh...

Страница 17: ...button The 2 program value is blinking Set the desired program Confirm the program settings by pressing Enter Repeat the procedure to set the programs for all weekdays Example To enable or disable th...

Страница 18: ...he Fuel autonomy sets to OFF and icon no fuel lights up on user interface Fill the container and set the Fuel autonomy setting to FULL If you refill the fuel container before it is completely empty re...

Страница 19: ...as you touch the keyboard the brightness of the display will increase to default value The Idle display mode setting offers the following options OFF The keyboard stays in the selected menu context In...

Страница 20: ...ervice menu entry and press the Enter button The display shows the randomly generated number between 1111 and 9999 This four digit number is different every time Add up the digits and then add the ser...

Страница 21: ...al analog NTC3 NTC2 NTC1 TC2 Relay Triac regulated Triac regulated Triac nonregulated Triac nonregulated Triac nonregulated Igniter starts Reset service timer Service time Heating time On time Missed...

Страница 22: ...ng service counters The Fumis ALPHA controller monitors the combustion system operation and provides different service counters The values are read only and cannot be modified The On time counter show...

Страница 23: ...ance is performed by authorized personnel only the Service time counter must be reset For instructions refer to chapter Viewing service counters on page 22 Replacing the battery Fumis ALPHA controller...

Страница 24: ...equipped with the fuel level sensor Solution Refill the fuel container If you are using the Fuel autonomy option reset this setting to Full by pressing the button ON OFF on the user interface No fuel...

Страница 25: ...s and when this counter reaches zero the Service icon starts blinking This value in hours is read only can be modified by authorized personnel only Solution Contact the service personnel Burning chamb...

Страница 26: ...on Power supply check Communication check OFF No power supply Faulty or not programmed Lit Power supply OK Fast blinking 5 blinks per second Communication OK Slow blinking 2 blinks per second Unit not...

Страница 27: ...errors on Fumis ALPHA keyboard Certain information stored in Fumis ALPHA controller is updated to Fumis ALPHA keyboard at startup for example configuration In case the Fumis ALPHA keyboard displays u...

Страница 28: ...timeout PAR7 PAR8 feeder PAR23 fan 1 PAR33 fan 2 PAR44 fan 3 PAR54 temperature PAR78 PAR79 PAR80 flame sensor BURNING Power levels 1 5 Auto High PAR9 18 feeder PAR24 28 fan 1 PAR34 38 fan 2 PAR45 49...

Страница 29: ...ected wood quality fan settings set with hidden parameters 59 61 is loaded Feeder 1 settings Pellet feeder is working in ON OFF mode The ratio between ON and OFF times defines the amount of supplied f...

Страница 30: ...13 Power 3 Feeder 1 OFF Time Power 3 feeder OFF time Defines the feeder pause at power level 3 in the Burning phase NOTE Not used when advanced regulation is selected 14 Power 3 Feeder 1 ON Time Powe...

Страница 31: ...e rose for more than 3 C min or if Flame Sensor gave the FLAME signal If so the Burning phase is started if not the test is repeated until timeout set with PAR1 21 Heat Up Fan 1 Speed FAN1 speed in He...

Страница 32: ...ng chamber FAN2 As Chimney Fan FAN2 Pressure Close Loop option 29 Test Fire Fan 2 Speed FAN2 speed in Test Fire sequence NOTE If the flue gases temperature is below PAR58 C in FAN2 for Room Heating mo...

Страница 33: ...eating mode FAN2 is switched off 38 Power 5 Fan 2 Speed FAN2 speed at power 5 Normal regulation defines the FAN2 speed at power 5 depends on the selected fan mode Fan 2 for Room Heating Fan 2 As Chimn...

Страница 34: ...rate in this sequence 45 Power 1 Fan 3 Speed FAN3 speed at power 1 NOTE FAN3 operates in ON OFF mode only The valid settings for this parameter are 0 FAN3 OFF or 255 FAN3 ON at maximum speed You must...

Страница 35: ...ode only The valid settings for this parameter are 0 FAN3 OFF or 255 FAN3 ON at maximum speed You must also set the PAR77 and an air temperature sensor NTC must be connected to I O T02 FAN3 only opera...

Страница 36: ...or restart temperature is PAR84 PAR50 in one degree resolution value 60 equals 60 C 51 Water Air Temperature Desired Water Air temperature in C In Stove mode defines the desired air temperature in xx...

Страница 37: ...hen the controller begins to decrease the burning power IMPORTANT When setting this parameter the actual value is double the value entered in PC PRO or UI except for stoves where value in PC PRO is th...

Страница 38: ...the number of blow cleanings before the heating device goes to FIRE STOP and performs the Erato cleaning 65 Ash Extraction Auger Duration Ash extraction auger activation duration in seconds Defines t...

Страница 39: ...e feeder in user fuel mode has the same speed as the default feeder setting 150 the feeder is 50 faster This parameter is set according to the selected pellets type factory settings It can be modified...

Страница 40: ...ection Delay Time delay before OFF detected in seconds Sensor signal is valid after certain time period expires Defines the time threshold for OFF flame detection The recommended value is 45 100 secon...

Страница 41: ...65 C PAR51 will automatically be set to this value If we assume that the heat loss is 5 C we achieve 60 C in heat accumulator which equals the desired temperature PAR84 NOTE The PAR51 value desired t...

Страница 42: ...ty No Parameter Description 92 Pellets Quality Defines one of the three pellets fuel quality types 1 feeder and fan 1 operate according to the hidden parameters 53 FeederFactorPelletsType1 and 54 FAN1...

Страница 43: ...C When normal regulation is used defines how many degrees before the desired temperature is reached the controller starts to decrease the burning power NOTE When modulation water pump is used Leveltro...

Страница 44: ...ional energetic heating sources First of all they do not pollute the environment because they are bio compact the CO emission is equal to zero or equal to the quantity one tree absorbs to product the...

Страница 45: ...ts may damage the functioning of your pellet stove which means that you will lose your warranty 6 0 CLEANING AND MAINTENANCE Regular cleaning of the pellet stove and the exhaust gas system is importan...

Страница 46: ...otton cloth or magazine paper with a small quantity of detergent for glass cleaning This cleaning should be performed only when the pellet stove is cooled down After each cleaning check the glass if t...

Страница 47: ...u should empty it and then clean it using a vacuum cleaner GAS SYSTEM It is recommended to clean the general gas system once a year To do it it is necessary to open the door to take out the ash tray A...

Страница 48: ...r system whether there is any obstacle in it EXHAUST GAS SYSTEM At the beginning of the heating season you should clean the exhaust gas system If the electrical cable is damaged replace it IMPORTANT F...

Отзывы: