29
Appendix B - List of parameters
Alarms Timeout
No.
Parameter
Description
0
Heat Up Timeout (Phase2)
Ignition Timeout (in minutes):
Maximum wait time for successful firing in the Ignition phase.
1
Ignition Test Timeout
(Phase3)
Test Fire Timeout(in minutes):
Maximum wait time for flame detection with igniter off in the Test
Fire sequence.
Fuel mode
No.
Parameter
Description
2
Fuel Type
Select Fuel Mode:
1=Auto
– default pellets related feeder and fan parameters are
used
2=User
– Pellets quality can be selected with PAR92. Based on
this selection different feeder and/or fan 1 settings are calculated
relatively to the default parameters, set with hidden parameters
53-58
3=Wood
– switch to wood mode. Based on PAR93 one of the
three preselected wood quality fan settings (set with hidden
parameters 59-61) is loaded.
Feeder 1 settings
Pellet feeder is working in ON/OFF mode. The ratio between ON and OFF times defines the amount of supplied
fuel in the burning chamber. All parameter values are set in *100msec (51 = 5.1 sec).
No.
Parameter
Description
Feeder: Heat Up
3
Heat Up Feeder OFF Time
Heat Up sequence feeder OFF time:
Defines the feeder pause (no dosing) during the Heat Up
sequence.
4
Heat Up Feeder ON Time
Heat Up sequence feeder ON time:
Defines the feeder dosing time during the Heat Up sequence.
Feeder: Fuel Ignition
5
Fuel Ignition Feeder 1 OFF
Time
Fuel Ignition sequence feeder OFF time:
Defines the feeder pause during the Fuel Ignition sequence.
6
Fuel Ignition Feeder 1 ON
Time
Fuel Ignition sequence feeder ON time:
Defines the feeder dosing time during the Fuel Ignition sequence.
Feeder: Ignition Test