13
30
Auger cleaning – Hopper activation time
From 0.0" to 4.0”
1
31
Encoder – Presence of encoder
off - on
ON
32
Time breaking – Hopper brake impulse
From 0.0" to 0.5”
0,2
33
Threshol pump – Circualtion pump starting threshold
From 20°C to 70°C 50
34
Exclude pressure – Pressure guage exclusion
off - on
ON
35
Pressure threshold - water circuit pressure alarm threshold
From 1.5b to 3.0b
2.5
Except those parameter in some cases you should change other parameter that can affect to functionality of the
of the stove ex. Difference off auto, preload lights etc.. and it is shown in table below
M9-4
01
Halt restart Interval between switch off and relighting
From 0' to 10'
5
02
Asp-min off Minimum time of smoke suction activation
From 0' to 20'
10
03
PRELOAD LIGHTS Duration of pellet hopper preload
From 0'’ to 255”
60
04
WAITING FIRE Interval between preload and start of "load pellet"
From 0'’ to 255”
150
05
EXN-SPEE PRELOAD Smoke suction in "preload lights" phase
From 600 to 2800
1800
06
Differen off auto Temperature delta in adjustment phase
From 0°C to 15°C
2
07
Del- off auto Stand-by delay adjustment
From 0' to 120'
2
08
Change output Waiting interval for power change
From 0'’ to 60'’
20
09
Enable remote
OFF/ON
ON
10
FROZEN KEYBOARD Enablement of keypad lock
OFF/ON
OFF
11
Black out
From 0'’ to 60'’
20
For exit simple just push button NO4 till go back to normal position of display.
4.5 DISPLAY OF THE CONTROL PANEL
The control panel enables easy control over the system through the direct controls. The control panel and LED
indicators inform the user on the operation which are running. You can change some operations of the system
through the control panel.
4.6 EXPLANATION OF THE CONTROL PANEL
The graphic explanation of the control panel is presented below
Operative working (user)
The operative working of the central line which is installed on your pellet stove is presented below. The
technical programming is analyzed below.
Before you turn on the pellet stove, the following symbol (off) appears on the display
Turning on the pellet stove
In order to turn on the pellet stove, press P4 for few seconds. Turning on the pellet stove will be displayed in
the following manner (pre-ventilation)