Connecting The CO2 Tank To The System
Step 5:
Connect the CO2 regulator to the tank.
Please
ensure that the tank valve is closed during this
process.
There is a small nylon washer attached to
the regulator which should be used to perform this
task.
DO NOT LOSE THE NYLON WASHER
Place the washer into the threaded section of the
regulator, and thread the regulator on to the tank as
far as possible by hand.
Use a wrench to finish securing the regulator if necessary. If you feel that you need excessive force to
tighten the regulator, unscrew it and start again. The solenoid has an indicator light and the CO2 ACC key-
pad has an “ON” setting to check for leaks. (Dishwasher soap at every connection.)
Step 6:
Find CO2 connection tubing. Locate the white plastic valve near one end of the tubing. We have
hand-written near that valve which side to connect to the chamber that you installed, and which side to
connect to the regulator assembly.
INLINE CHECK VALVE #2 (White)