background image

      

 © Copyright 2004 - 2020 EcoSmart Inc. All rights reserved. V0120

27. Press and hold sparker button to verify presence of spark.   

Look inside ignition wind guard for visible spark.

NA 27. Press and hold sparker button to verify presence of spark.  Look inside ignition wind guard for visible spark.

28. Ensure the control knob (or “key”) is in the OFF position.  

29. Use a leak detecting solution to check all connections before 

operation. 

30. Slowly open main gas supply shut-off valve and check for any 

bubbles on inlet side of gas system.  If bubbles are present, close 

main gas supply shut-off valve immediately and tighten all fittings 

again using adjustable wrenches.

31. If no leaks are present, a first lighting and final leak check can be 

performed.  

32. With main gas supply shut-off valve open, turn control valve 

to LOW/IGNITION position.  Press and hold sparker button, slowly 

depress control knob and hold in for 3-5 seconds.  Burner should be 

ignited.  Verify no bubbles are present on outlet side of gas system.

33. If no leaks are present on outlet side of gas system, the burner is 

ready for normal operation.  If leaks are present, turn control valve to 

the OFF position and close main gas supply shut-off valve.  Re-tighten 

all fittings and repeat 32.

Adequate and constant ventilation is important to keep the appliance 

functioning properly and safely, including ventilation of the appliance 

undersides. Setting the appliance without air circulation underneath 

can cause heat build up and improper combustion.  Do not remove 

the feet or operate the appliance with missing feet.
1. Locate the appliance and the LP tank cover on hard, flat surface 

that extends the full length and width of the appliance.  The 

appliance and the LP tank cover can be placed on combustible 

surface (such as wood deck) or on non-combustible material (such 

as concrete).  Ensure all clearances to the sides and clearances 

above the appliance are observed at all times (see figures 1 and 2).

2. Maintain a minimum air space of ½” (12.5mm) between the ground 

surface and the underside of the appliance sidewalls by adjusting 

the articulating feet up or down as necessary.

3. Do not place the appliance over grass, artificial turf, carpet or 

any uneven surface, as this will block the airflow underneath the 

appliance. See figure 1.

4. Follow the same instructions above for the LP tank cover (if 

purchased).  See figure 1. 

CORRECT

Min 0.5’’

(12.5mm)

INCORRECT

CORRECT

Min 0.5’’

(12.5mm)

INCORRECT

Figure 1

  WARNING  

Do not burn without black glass charcoal on burner.

Burner Assembly - Natural Gas

Содержание ESF.2.B.G16

Страница 1: ...t operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation DANGER If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues keep away from the appliance and immediately call your gas supplier or fire department After leaving the area call your gas supplier or fire department Failure to follow ...

Страница 2: ...ll be limited to a cylinder of 30 lb capacity or less x Do not use store or transport cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape x When transporting keep cylinder secured in an upright position with cylinder valve turned off WHEN CONNECTING FOR USE x Use only in compliance with applicable codes x Read and follow ...

Страница 3: ...sa com MAD Design USA 5875 Green Valley Circle Suite 100 Culver City CA 90230 T 1 888 590 3335 E info mad usa com LISTING AND CODE APPROVALS A Appliance Certification MODEL ESF 2 B G37 ESF 2 B G16 LABORATORY Underwriters Laboratories Inc UL TYPE Decorative Gas Fired Outdoor Fireplace STANDARD Outdoor Decorative Gas Appliances ANSI Z21 97 2017 CSA 2 41 2017 This appliance has been tested in accorda...

Страница 4: ...re You Start Gas Hookup Standard Equipment Received Burner Assembly Propane Burner Assembly Natural Gas Installation Natural Gas Lighting and Operating Troubleshooting Service and Maintenance Reference Materials Warranty 3 3 4 5 6 7 8 9 10 11 13 14 17 18 19 20 21 22 23 24 ...

Страница 5: ... h G37T ESF 1 B G37 PROPANE NATURAL GAS IDEAL INLET PRESSURE 11 in WC 2 74 kPa 7 in WC 1 74 kPa MAXIMUM INLET PRESSURE 14 in WC 3 48 kPa 10 5 in WC 2 61 kPa MINIMUM INLET PRESSURE 8 in WC 2 00 kPa 3 5 in WC 0 87 kPa WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury and or loss of life A This appliance is equipped with a s...

Страница 6: ...f flammable vapors are present ii Never smoke while lighting the appliance 2 LOCATING THE FIRE i Ensure there is enough ventilation for safe operation ii Locate the appliance away from combustible materials by observing the minimum clearance distances depicted in this manual especially for items susceptible to movement iii Locate the gas hose out of pathways where people may trip over it or in are...

Страница 7: ...nce See figure 1 4 Follow the same instructions above for the LP tank cover if purchased See figure 1 CORRECT Min 0 5 12 5mm INCORRECT CORRECT Min 0 5 12 5mm INCORRECT Figure 1 Position the appliance adjacent to the gas supply line or LP gas supply cylinder DO NOT locate the appliance where it will get excessively wet or submerged in water Minimum Clearances Note Measurements are distances closest...

Страница 8: ...the gas valve control knob after it is installed and connected to the gas supply because the ON OFF gas valve is used to turn the burner on and off The location for the installation must be out of the pathways where people may trip over it or in areas where the hose may be subject to accidental damage In addition for LP Gas Models Be certain to mount or set the LP gas cylinder on a flat stable sur...

Страница 9: ...ion should be done by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Note A listed and Commonwealth of Massachusetts approved 3 8 in 9 5mm T handle manual shut off valve and flexible gas connector are connected to the 3 8 in 9 5mm control valve inlet If substituting f...

Страница 10: ...cylinders must have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply natural gas line or LP gas cylinder The LP gas cylinder supply system must be arranged for vapor withdrawal The LP gas cylinder used must include a collar to protect t...

Страница 11: ...lt causing property damage personal injury or loss of life WARNING For outdoor use only Installation and service must be performed by a qualified installer service agency or the gas supplier CAUTION DO NOT DISCARD THIS MANUAL Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation DANGER If you smell gas Shut off g...

Страница 12: ...ontrol valve to the back of the control panel plate using the provided screws The valve must be installed with orientation as shown 8 Install the turn Knob 1 Locate the Control panel location on the Unit remove the four plastic screw caps and unscrew the cover plate from the Unit 2 Keep the four screws and screw caps the gas control plate should be directly behind the Ecosmart cover plate The cove...

Страница 13: ... opening first then place lower the burner into its final location Install the grommet by sliding it into the slot place the burner into its final position 6 Position the burner assembly so that the gas input flexible line where the orifice is located is pointing towards the control plate cutout location of the surround Carefully uncoil the thermocouple tube Feed the flexible gas line thermocouple...

Страница 14: ...nnections will cause operation issues 14 Plug the Ignitor wire and grounding wire into the back side of the sparker These wires can be plugged into either port on the back side of the sparker box 14 Plug the Ignitor wire and grounding wire into the back side of the sparker These wires can be plugged into either port on the backside of the sparker box 15 Insert the fully assembled Control Panel int...

Страница 15: ... the OFF position and close main gas supply shut off valve Re tighten all fittings and repeat 24 Adequate and constant ventilation is important to keep the appliance functioning properly and safely including ventilation of the appliance undersides Setting the appliance without air circulation underneath can cause heat build up and improper combustion Do not remove the feet or operate the appliance...

Страница 16: ...ate bypass tube from the control valve 5 With a flat blade screwdriver remove the valve orifice 52 and replace with the natural gas orifice 43 5 With a flat blade screwdriver remove the valve orifice 52 and replace with the natural gas orifice 43 6 Re install the low rate bypass tube 6 Re install the low rate bypass tube 7 Remove the flare fitting adaptor from the valve gas input valve 7 Remove th...

Страница 17: ...ible gas line thermocouple tube grounding wire and the ignitor wire through the burner location opening first then place lower the burner into its final location Install the grommet by sliding it into the slot place the burner into its final position 15 Linear burners only this step is not required for round burners Same as propane edit 6 Position the burner assembly so that the gas input flexible...

Страница 18: ...securely tighten 1 2 turn with a 10mm wrench Damage to the thermocouple and or loose connections will cause operation issues 22 Plug the ignitor wire and grounding wire into the back side of the sparker These wires can be plugged into either port on the back side of the sparker box 22 Plug the Ignitor wire and grounding wire into the back side of the sparker These wires can be plugged into either ...

Страница 19: ... close main gas supply shut off valve Re tighten all fittings and repeat 32 Adequate and constant ventilation is important to keep the appliance functioning properly and safely including ventilation of the appliance undersides Setting the appliance without air circulation underneath can cause heat build up and improper combustion Do not remove the feet or operate the appliance with missing feet 1 ...

Страница 20: ...l gas appliance sharing the same line add the BTU output to provide to provide the proper pipe size Natural Gas Pipe Sizing Chart Maximum delivery capacity of pipes in BTU hour at different diameters and lengths for an initial pressure of 7 inch water column Note 1 cubic feet per hour 1000 BTU As an example to install a Brown Jordan Fires FLO with a G37 burner 65 000 BTU and located about 90 feet ...

Страница 21: ...gas supplier from a neighbors phone Follow gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the gas control knob on propane tank if equipped never use tools If the valve won t turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use the appl...

Страница 22: ...ns on Page 14 E Thermocouple not properly secured to valve Ensure the thermocouple is tightened to control valve using 10mm wrench 3 Blue Flames A This is a result of normal operation and flames will begin to yellow as unit is allowed to burn for 15 20 minutes No action required B Improper air fuel mixture related to air shutter position The air shutter is adjusted from the factory for optimal per...

Страница 23: ...orifice The orifice is what controls the amount of gas that your appliance is using Sometimes the shape of an orifice can produce a whistling depending on the gas flow rate and gas pressure If repositioning the flex lines in your appliance did not fix the whistling noise disconnect the gas supply to the burner and remove the orifice Blow through the orifice to check for a whistle If your orifice w...

Страница 24: ... glass charcoal and examine burner Vacuum and wipe out as needed Use caution when cleaning these areas 2 Inspect for warping and corrosion Repair as necessary 3 Check the hose connecting the LP gas cylinder to ensure it is not damaged Replace as necessary 4 Verify air shutter area is clean Burner Ignition and Operation 1 Verify all gas connections are tight and leak free 2 Clean burner top inspect...

Страница 25: ...F 3 P CPF 1 2 Female Flare x 3 8 Male Flare Adaptor ESF 2 P FMA 22 Whistle free Stainless Steel Flex Line 1 2 Fittings ESF 2 P F22 Grounding Wire 36 ESF 1 P G36 Flame Sensor Assembly ESF 2 P FSA LP Hose Regulator 10 ESF 1 P H10 LP Low Rate Valve Orifice 52 ESF 2 P LR O52 LP Burner Orifice 40 ESF 2 P O40 NG Low Rate Valve Orifice 43 ESF 2 P LR O43 NG Burner Orifice 29 ESF 2 P O29 Sparker Box ESF 1 ...

Страница 26: ... shipping improper handling improper operation abuse misuse accident or unworkmanlike repairs 4 use of fuels other than those specified in the Operating Instructions 5 Installation or use of components not supplied with the Product or any other components not expressly authorized and approved in writing by MAD Design USA and or 6 modification of the Product not expressly authorized and approved in...

Страница 27: ......

Страница 28: ...MAD Design USA 5875 Green Valley Circle Suite 100 Culver City CA 90230 T 1 888 590 3335 E info mad usa com V0120 This product is distributed by EcoSmart Inc DBA MAD Design USA ...

Отзывы: