background image

 

Range 3030 

– 3031ARD 

Instruction manual

 

 

ECOSAFE | Date of the document : 26/06/2019 – Version : 01 

 

Warning:

 Always wear adequate and suitable protective clothing when working with hazardous chemicals!  

Attention:

  Do  not  dispose  chemical  waste  through  your  canalization  or  domestic  waste!  Follow  your  local  laws  and  directives  when 

disposing  fluid  waste  or  other  chemicals!  Please  ask  your  official  safety  inspector  and  your  environmental  authorities  for  more 

information and applicable law!  

 

Reset  

Hold  the  Snooze  &  Reset  button  2  for  3  seconds  to  reset  all  channels.  Now  the  Status  LEDs  3  change  to  green  light.  For  those 

containers that still hit max. fill level, the alert will recur automatically.  Press and hold of the Snooze & Reset button is approved by a 

key tone.

 

 

4.  INTERNAL EQUIPMENTS 

 

The cabinet is provided with 1 retention tank. The waste recovery system is equipped with a 12L white canister, one sound and visual 

alarm, one disc level sensor, one funnel, one hose and two adapters.  

 
The  retention  tank  has  to  be  positioned  at  the  bottom  of  the  cabinet.  If  you  want  to  use  it  as  a  storage  area,  you  must  place  in  a 

perforated cover plate (P/N C148) that is suitable for your containment sump. The latter has a retention capacity of 20 liters.  

 

Be aware that placing a perforated cover plate decreases the total retention capacity of your containment sump. The volume of 

your containment sump is approximately reduced by 3 liters. 

 

5.  STORAGE 

 

Your safety cabinet is exclusively destined to store chemicals in laboratories, industries, schools

… in closed containers.  

It must not store high concentrated corrosive products.  

We remind  you  that  the  storage  of corrosives  can  alter  the  quality  of  your safety  equipment.  On  the  other  hand,  we  remind  you  that 

damages due to a bad use of the equipment and in particular to corrosion won

’t be covered by our warranty.  

It is highly recommended to connect your safety cabinet  to a ventilation system.  
 

Warning ! The HPL plank situated at the upper part of the cabinet must not be used as a storage location, neither be removed. 

 

6.  VENTILATION 

 

First of all, you need to remove the red covers, which are positioned on the ventilation openings of the cabinet.  

As to evacuate the vapors, you need to connect the connecting sleeve, which possesses the  red 

arrow indicated “OUT”. The air inlet 

possesses a green arrow indicated “IN”.  

 

We highly recommend connecting your safety cabinet to a ventilation system, as to evacuate the eventual vapors contained in it.  

The air renewal has to be at least 10 times the volume of the cabinet, per hour. Moreover, ensure that the ventilation runs 24h/7.  

 

In compliance with the standard EN 14470-1

 and as to avoid any confinement of the vapors, ventilation is required to assure an air 

renewal. Every user has to contact his chemicals supplier or the safety officer of his company, before storing any chemicals. See our 

ventilation and filtration boxes range technical datasheet.  

Содержание 3030ARD

Страница 1: ...Range 3030 3031ARD Instruction manual ECOSAFE Date of the document 26 06 2019 Version 01 0 Instruction manual For safety cabinet Picture Model 90 minutes Bench not included Model 3031ARD ...

Страница 2: ...1 CONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 7 5 Storage Page 7 6 Ventilation Page 7 7 Safety controls Page 9 8 Spare parts Page 9 9 Recycling Page 9 10 Warranty Page 9 11 Control sheet for the user Page 11 ...

Страница 3: ...ion openings with a connecting sleeve diameter 100 mm for an eventual connection Ventilation ducts with a thermo fuse Thermo expanding door seals allowing to insulate the content of the safety cabinet in case of a fire Self closing doors with the possibility to keep the doors open If the temperature rises to 43 C the doors are closed automatically External dimensions H 635 x W 605 x D 630 mm Stora...

Страница 4: ... ensure that you also received a set of two keys Your safety cabinet has to be installed used and maintained as to guarantee the users protection Swing doors The swinging doors can be open by pulling the handle The automatic closing system allows the doors to be closed systematically after every use if the blocking doors system is not activated Door closing mechanism The door closing mechanism is ...

Страница 5: ...h with green LED 2 Snooze and reset button 3 Status channel 1 with green LED Back view 4 Output Potential free switch channel 1 6 DC input 24V electrical power supply 7 Input level sensor channel 1 Technical features Dimensions H 105 x W 180 x D 55 mm Weight ca 620g Power supply 24V Switching power 24V 2A Power consumption Max 4W Operating temperature 5 C to 40 C Display LEDs ...

Страница 6: ...ap The floater on your SafetyWasteCap might be stuck or unmovable by sticky or viscous fluids Check floater and level control mechanism constantly for dirt or contaminants The floater must be freely movable Clean and purge the floater if necessary with a suitable solvent or clean water Commissionning 1 Power supply Connect the Signalbox to your power supply using the delivered ac dc adapter 6 Now ...

Страница 7: ...level During alert LED at the disc sensor flashes up please turn the potentiometer anti clockwise until the alert ends LED at the disc sensor off At next please turn the potentiometer clockwise and leave it close next to a position where the disc sensor alerts Put the sensor into a position above the fluid level to test the correct function If the sensor also alerts here please readjust Level aler...

Страница 8: ...f your containment sump is approximately reduced by 3 liters 5 STORAGE Your safety cabinet is exclusively destined to store chemicals in laboratories industries schools in closed containers It must not store high concentrated corrosive products We remind you that the storage of corrosives can alter the quality of your safety equipment On the other hand we remind you that damages due to a bad use o...

Страница 9: ...rifies the toxic vapors in the box and rejects it in the room in a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at leas...

Страница 10: ... Contact us Locking system set of keys Contact us Standardized pictogram P N PICTOEN System to maintain the doors open Contact us Door closer mechanism Contact us Containment sump P N B148 Perforated cover plate P N C148 9 RECYCLING The safety cabinet can be entirely dismounted Various elements such as the steel can be recycled Ensure to respect the national and local waste disposal terms Those el...

Страница 11: ... a third party The equipment had a modification or a repair by the user or a third party without any prior written authorization by ECOSAFE In case of a bad use of the equipment In case of a normal attrition of the equipment In case of a bad installation of the equipment In case of damage caused by the corrosion The activation of the warranty won t extend the term Our warranty stops if the custome...

Страница 12: ...g of the doors works correctly The doors blocking system works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The shelves and the containment sump are clean T...

Отзывы: