background image

6

INSTALLATION NOTES

PRELIMINARY MEASURES

1

1.  Place the unit in the location of installation.

2

2.  Remove top cover by loosening thumb screws and 

pulling upward in a straight motion. Set the top 
aside. Remove side panel which is attached with 
hook & loop tape. Grasping the edges on both 
ends, pull outward tipping top toward you.  
You may remove both sides for best access if  
space allows.

3

3.  Carefully remove the carton located in the base of 

the unit. This carton contains the ultraviolet light 
and quartz sleeve.

4

4.   Carefully unwrap the valve assembly and 

connect it to the unit using the two unions as 
shown in the accompanying diagram. Make sure 
all unions are snug and free of “play.”

5

5.    Plumb the unit into the water service line using the 

unions provided paying close attention to the inlet 
and outlet.

 /

"1//

GENERAL 
PRECAUTIONS:

•  Installation must be done 

by a qualified plumber in 
accordance with local codes. 
Failure to do so can result 
in damage not covered by 
your SpringHouse warranty. 
Installation by a licensed 
plumber is recommended.

•  SpringHouse can be installed 

outdoors but must be 
protected from freezing, 
excessive heat and direct 
sunlight. Failure to do so can 
result in component failure, 
water leakage, and/or  
property damage and will  
void the warranty.

•  Install on cold water  

lines only. 

•  Install after the  

pressure regulator.

•  Install after any pressure 

tanks or other water treatment 
equipment such as softeners.

•  Flow must be in the direction 

indicated on the canister tops.

•  When installing unit, be sure 

to position it for easy access 
to the filter canisters for 
maintenance purposes.

•  Unit must be located  

within 6 feet of a  
110v - 120v gfci outlet.

•  Inlet and outlet plumbing  

1 inch.

•  Maximum supply pressure  

250 psi. 

•  Operating temperature range 

of 35-100 degrees Fahrenheit.

•  Rated service flow of up to 

8 g.p.m. The use of reducers 
and/or excessive fittings can 
result in a decreased flow 
rate and is not recommended. 
Household water pressures  
of less than 40 psi will result 
in a noticeable reduction in 
flow rate.

Содержание SpringHouse

Страница 1: ...Owner s Manual ...

Страница 2: ...ringHouse is to be installed Otherwise you will not be able to install and or remove the UV lamp and the quartz sleeve NOTE Installation must be done by a qualified plumber in accordance with local codes Failure to do so can result in damage not covered by your SpringHouse warranty SpringHouse s unique design allows for easy maintenance and operation The System Bypass function allows your water so...

Страница 3: ..._________________________________________________________________ SPRINGHOUSE SPECIFICATIONS Maximum Flow Rate 8 G P M 60 psi Dimensions 41 L x 16 W x 40 H Inlet Outlet Pipe 1 inch schedule 80 PVC Operating Temperature Range 35 to 100 degrees Fahrenheit Inlet Pressure Range 25 to 60 psi Operating Supply Pressure Range 25 to 250 psi Warranty 2 Years parts and labor Micron Rating 1 micron absolute A...

Страница 4: ... Chamber Plug Cap located atop UV chamber by pulling upwards 4 Remove UV Chamber retainer fitting by turning counter clockwise 5 Locate the shipping tube containing the UV Lamp glass lamp sleeve spring nylon washer and rubber O ring Caution handle UV lamp and sleeve carefully to avoid breakage 6 Lubricate the top inch of the outside of the lamp sleeve with either vegetable oil or some type of inge...

Страница 5: ...hamber Step 5 MAZ filter Step 6 Anti scalent sequestering agent polyphosphate Step 7 1 micron filter absolute particulate filter Specialty filters are available for treatment of unique contaminants These are normally installed in place of the sequestering agent in canister 6 Ask your Independent Business Owner for details Additional Information Filter life varies with all filters because of broad ...

Страница 6: ... Failure to do so can result in damage not covered by your SpringHouse warranty Installation by a licensed plumber is recommended SpringHouse can be installed outdoors but must be protected from freezing excessive heat and direct sunlight Failure to do so can result in component failure water leakage and or property damage and will void the warranty Install on cold water lines only Install after t...

Страница 7: ... Insert provided grounding wire into Grounding Lug connection point and tighten clamp screw 3 3 Attach opposite end of grounding wire to a proper household ground Provided Grounding Clamp to be used metallic plumbing entering facility CAUTION failure to properly ground the unit could lead to serious injury or death ...

Страница 8: ...ack canister cap on the unit and filter is numbered Take filter canister 1 remove the filter from the canister and set aside CAUTION Do not over tighten canisters when installing 5 5 Being careful to match the number on the blue canister with the number on the black canister head carefully screw the blue canister into the black portion of the filter canister Hand tighten the canister Snug with sup...

Страница 9: ... See figure 5 9 9 Plug the ballast into the top of the UV lamp See figure 6 10 10 Place the plastic cover over the retainer to protect the top to the UV lamp The lamp should be seated low enough in the sleeve so that when the plastic cover is in place there is clearance between it and the cabinet top See figure 7 Plug ballast into properly grounded 110 120 Volt household receptacle 3 3 The quartz ...

Страница 10: ...on REASSEMBLY 2 3 Lower cover into place Tighten thumb screws 11 Replace side panels with hook loop tape OPERATION AND MAINTENANCE NOTICE UNPLUG SYSTEM BEFORE PERFORMING ANY OF THE MAINTENANCE PROCEDURES LISTED To open the inlet outlet or bypass valve Turn handle in a counter clockwise direction To close turn in a clockwise direction NOTE Handle will only rotate 1 4 turn Bypass valve should be clo...

Страница 11: ...is secured in bucket or drain 14 Open outlet valve see illustration page 5 15 Close bypass valve see illustration page 5 16 Observe tubing to determine that all air has escaped the unit 17 Close pressure relief valve and coil tubing on top of unit 18 Check for leaks before leaving installation 18 Replace unit housing and cover 19 Some cartridges may contain a small amount of fines very fine black ...

Страница 12: ...ressurize unit If full flow is not restored repeat the procedure with canisters 1 2 3 5 and 7 6 If full flow is still not restored it is likely that a filter is clogged or faulty Refer to page 11 regarding the changing of filters Gradual Reduction In FlowVolume or Pressure Possible Causes 1 Water pressure to the house from the source has been reduced 2 One or more filter cartridges in the SpringHo...

Страница 13: ...13 INSTALLATION NOTES ...

Страница 14: ...14 INSTALLATION NOTES ...

Страница 15: ...on or usage of the filters and lamps Warranty Limitation Installation of this unit on other than a potable water system will immediately and completely void the warranty The warranty is also voided and provides no coverage where the damage results from improper installation alterations abuse or misuse as determined by EcoQuest International ALL WARRANTIES IMPLIED BY STATE LAW INCLUDING THE IMPLIED...

Страница 16: ... antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the Independent Business Owner or an experienced radio TV technician for help FCC DECLARATION OF CONFORMITY EcoQuest Healthy Living Technologies SpringHouse are Trademarked by EcoQuest International EcoQuest Internation...

Отзывы: