13
INITIAL PARAMETER SETUP [USERS SET UP]
Lithium (LiPo/Lilo/LiFe) Program
The program is only suitable for charging/discharging lithium-polymer batteries with a
nominal voltage of 3.6/3.7/3.3V per cell. Different batteries have different charging
techniques. There are two methods termed as constant voltage and constant current.
The charge current varies according to battery capacity and specification. The final
voltage is very important; it should precisely match the voltage of the battery: Li-ion is
4.1V, LiPo is 3.7V, LiFe is 3.6V per cell. The current and voltage of the battery should
be correctly set. When you want to change the values of any parameter, please press
START/ENTER key to make it blink and then use DEC or INC to change the value.
Then press START/ENTER key again to store the value.
Charging of Lithium battery
The program provides maximum capacity protection. If the
Delta-peak voltage cannot be detected or the safety timer times
out, the charge process will stop automatically when the battery
reaches the user-set maximum charge capacity.
The beep to confirm users' operation sounds every time a button
is pressed. The beep or melody sounds at various times during
operation to confirm different mode change. These sounds can
be switched on or off.
This function monitors the voltage of the input battery used to
power this charger. If the voltage is lower than user-set value, the
program will end forcibly to protect the input battery.
The left side of the first line shows the type of battery you
choose. The value on the left of the second line of the charger
is the setting for charge current. After setting the current and
voltage, press and hold the START/ENTER key for more than
3 seconds to start the process.
This displays both the number of cells you set up (“S”), and
the number of cells that the processor detects (“R”). If both
numbers are identical you can start charging by press
START/ENTER button. If not, press BATT TYPE/STOP
button to go back to the previous screen to carefully check
the number of cells of the battery pack before going ahead.
This screen shows the real-time status during the charge
process. Press BATT TYPE/STOP key once to stop the
charge process.
INC
INC
INC
INC
DEC
DEC
DEC
DEC
-
-
+
+
INC
INC
DEC
DEC
- +
INC
INC
DEC
DEC
-
-
+
+
Start
Enter
Batt type
Stop
‘>3 seconds’
Start
Enter
Charged
capacity
Number
of
cells
Charging
time
Charging
current
Battery
voltage
Содержание Electron 65 Quad