12
INITIAL PARAMETER SETUP [USERS SET UP]
I NC
DEC
I NC
DEC
DEC I NC
DEC I NC
DEC I NC
DEC I NC
I NC
DEC
INC
INC
INC
INC
INC
INC
DEC
DEC
DEC
DEC
DEC
DEC
-
-
-
-
+
+
+
+
This shows the voltage threshold for automatic charge termination
of NiMH and NiCd batteries. The value ranges from 5 to 20mV
per cell. Setting the trigger voltage higher brings the danger of
overcharging; whereas setting it lower brings a possibility of an
incomplete charge. Please refer to the technical specification of
the battery. Default settings: NiCd: 12mV / NiMH: 7m
There is a 3-pin port on the left of the charger used as USB
interface or temperature sensor port. When set as a USB port,
you can connect the charger to your PC through the optional
USB cable to monitor the charging process through optional
software. When temperature is selected, you can attach the
optional temperature probe to monitor the battery during charging.
The maximum temperature of the battery can be set during
the charge process. Once the temperature of battery reaches
this value the process will be terminated automatically.
The battery becomes warm during charge/discharge cycles. The
program will insert a time delay after each cycle to allow the battery
enough time to cool down before beginning next cycle. The value
ranges from 1 to 60 minutes.
When the charge process starts, the integrated safety timer starts
to run simultaneously. If an error is detected or the charger cannot
determine if the battery is fully charged, this unit is programmed to
prevent overcharging and will stop automatically. Please refer to
the below statement to calculate the timer the recommended
timer value.
Safe Timer Calculation
When charging NiCd or NiMH batteries, divide the capacity by current, then divide the
result by 11.9; set this number of minutes as the value for the safety timer. If the charger
stopped at this time threshold, about 140% of the capacity will have been fed into the
battery.
For example:
Capacity
Current
Safety Time
2000mAh
2.0A
(2000/2.0=1000)/11.9=84 minutes
3300mAh
3.0A
(3300/3.0=1100)/11.9=92 minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 minutes
Содержание Electron 65 Quad