1 GENERAL 

FEATURES 

 

1.1 

Installation must be performed by properly trained and experienced service 
technicians only. 

 

1.2 

Do not attempt to turn the AR gear motor shaft by hand or by means of a wrench, 
otherwise damage to the gear train may occur. 

 

1.3 

Before servicing make sure that power supply to the gear motor has been 
disconnected. 

 

1.4 

Check carefully all instructions before operating the AR gear motor automatically. 

 

1.5 

Each AR gear motor is supplied with a label fixed under the conduit plug. 

 

1.6 

The main servicing data and technical features of the gear motor are indicated on 
the label. All technical functions are specified in the relative technical data sheet. 

 

1.7 

Before installing or operating the AR gear motor make sure that its employment 
complies with the range of performances reported on the label. 

 

1.8 

When positioning the gear motor consider that it must be easily accessible in order 
to be able to perform wiring and adjustment of endswitches.  

 

1.9 

The AR gear motor can be installed in any location included in the range of 
electrical protection IP54, except where acid fumes or other deteriorating vapour 
might attack its metal parts or where gas leaks or explosive vapours are present in 
the atmosphere. In environments with high salt percentage, the fastening screws 
should be zinc or cadmium plated, not made of brass or stainless steel. 

 

Содержание AR2 SE Series

Страница 1: ...NANCE AND CHECKS 7 8 1 MAINTENANCE 7 8 2 CHECKS 8 9 REPLACEMENT 8 10 ELECTRONIC CONFIGURATION 8 10 1 ELECTRONIC CONFIGURATION AR2 SE1 INPUT SIGNAL 0 10V OUTPUT SIGNAL 0 10V 9 10 2 ELECTRONIC CONFIGURATION AR2 SE2 INPUT SIGNAL 4 20 MA OR 0 10V OUTPUTSIGNAL 0 10V 10 10 3 ELECTRONIC CONFIGURATION AR2 SE4 INPUT SIGNAL 0 10V 11 10 4 ELECTRONIC CONFIGURATION AR2 SE5 INPUT SIGNAL 4 20 MA 12 10 5 ELECTRON...

Страница 2: ... motor are indicated on the label All technical functions are specified in the relative technical data sheet 1 7 Before installing or operating the AR gear motor make sure that its employment complies with the range of performances reported on the label 1 8 When positioning the gear motor consider that it must be easily accessible in order to be able to perform wiring and adjustment of endswitches...

Страница 3: ...odel refer to 10 Local control station Auto Manual and Open Close Stop Rating of el contacts limit and auxiliary switches 0 5 A 48 Vdc and Vac Enclosure Rating IP 54 according to IEC 529 Duty cycle continuous 100 Conduit knockouts 2 x Pg 13 5 3 INSTALLATION 3 1 The AR gear motor must be positioned so that the square shaft POWER END is turned towards the device to be put in motion 3 2 If no other a...

Страница 4: ...nd 2 extra holes on request if pressurizing of the motor is requested 4 7 All wires must comply with local prescriptions and in any case their section must be ranging between 1 and 1 5 mm 4 8 Connection piping recommended HO7V U G 1 5 mm 4 9 The wiring diagrams show the AR2 E gear motor at end position closed 0 WARNING An immediate accident may occur onto circuit board due to wrong wiring Check it...

Страница 5: ... right side introducing the pin into one of the holes on the sides of the blue cam S3 or S4 according to the need and lift it to required angle position Picture 2 5 2 4 By the blue cam in the rearmost position at first use the lever on its curved side to move the blue cam to a more suitable position to perform adjustment 5 2 5 Cam adjustment is possible in both directions and along the whole rotat...

Страница 6: ...the right handside up to 45 Then the actuator will rotate by 45 between 45 and 0 with the entire signal 4 20 mA or 0 10V with rotation counter clockwise dip switch no 1 on the left handside up to 90 Then the actuator will rotate by 45 between 90 up to 45 with the entire signal 4 20 mA or 0 10V 3 In order to widen the working range it is possible to set any degree of angle between 45 and 90 with a ...

Страница 7: ...ll adjustments are already set at factory Hence it is recommended to avoid any intervention on cams and potentiometer 7 2 Warning potentiometer is installed for card balancing purposes ONLY Consequently it is not to be used 8 MAINTENANCE AND CHECKS 8 1 MAINTENANCE 8 1 1 AR2 gear motor does not require any particular current maintenance 8 1 2 AR2 gear motor does not require any lubrication since th...

Страница 8: ...pply from the AR2 E motor remove the gear motor s cover disconnect electric wiring remove the levers between the AR2 E gear motor and the controlled device install the new gear motor proceeding as per instructions given in the foregoing chapters 10 ELECTRONIC CONFIGURATION The digital electronic board mounted on AR2 gear actuator enable to set various features options like rotation direction resol...

Страница 9: ...ignal 0 10 V d c N A 6 Impedance at 4400 Ohm only for Input Signal 0 10V Impedance at 250 Ohm only for Input Signal 0 10V For other setting please look here below 3 4 OFF ON STANDARD setting Input and Output signal always aligned For example 2V input e 2V output 3 4 OFF ON REVERSE OUTPUT only for counter clockwise rotation For example 2V Input signal and 8V Output Signal 3 4 OFF ON DS 3 turned ON ...

Страница 10: ...mA DS 6 MUST be turned ON 6 Impedance at 4400 Ohm only for Input Signal 0 10V Always turned ON with Input Signal 4 20 mA Impedance at 250 Ohm only for Input Signal 0 10V For other setting please look here below 3 4 OFF ON STANDARD setting Input and Output signal always aligned For example 2V input e 2V output 3 4 OFF ON REVERSE OUTPUT only for counter clockwise rotation For example 2V Input signal...

Страница 11: ...ion 200 steps 3 4 Please refer to the below reported scheme 5 Input Signal 0 10 V N A 6 Impedance at 4400 Ohm only for Input Signal 0 10V Impedance at 250 Ohm only for Input Signal 0 10V For special setting please look here below 3 4 OFF ON DS 3 turned ON and DS 4 turned OFF Actuator rotates for 90 with Mid Low Input Signal For example 0 5V with rotation of 90 3 4 OFF ON DS 3 turned OFF and DS 4 t...

Страница 12: ... Resolution 125 steps High Resolution 200 steps 3 4 Please refer to the below reported scheme 5 N A Input Signal 4 20 mA 6 N A DS 6 MUST be turned ON For special setting please look here below 3 4 OFF ON DS 3 turned ON and DS 4 turned OFF Actuator rotates for 90 with Mid Low Input Signal For example 4 12 mA with rotation of 90 3 4 OFF ON DS 3 turned OFF and DS 4 turned ON Actuator rotates for 90 w...

Страница 13: ...PUT and OUTPUT always aligned 5 N A Input Signal 4 20 mA 6 N A DS 6 MUST be turned ON For other setting please look here below 3 4 OFF ON STANDARD setting Input and Output signal always aligned For example 2V input e 2V output 3 4 OFF ON REVERSE OUTPUT only for counter clockwise rotation For example 2V Input signal and 8V Output Signal 3 4 OFF ON DS 3 turned ON and DS 4 turned OFF Actuator rotates...

Страница 14: ...5 N A Input Signal 4 20 mA 6 N A DS 6 MUST be turned ON For other setting please look here below 3 4 OFF ON STANDARD setting Input and Output signal always aligned For example 2V input e 2V output 3 4 OFF ON REVERSE OUTPUT only for counter clockwise rotation For example 2V Input signal and 8V Output Signal 3 4 OFF ON DS 3 turned ON and DS 4 turned OFF Actuator rotates for 90 with Mid Low Input Sig...