26
OPERATING
&
INSTALLATION
INSTRUCTIONS
FOR
PEDESTAL
WOOD
HEATERS
Clearances
to
heat
‐
sensitive
materials
and
floor
protection
7.3
FLOOR
PROTECTOR
If
the
wood
fire
is
to
be
installed
on
top
of
a
combustible
floor,
it
must
be
guarded
by
a
heat
resistant
material
as
shown
on
the
dotted
line
area
of
the
above
figures.
Install
a
925
mm
(G)
x
1000
mm
(F)
floor
protection
of
12
mm
of
thickness
with
thermal
conductivity
of
0.8
m
2
K/W
per
4
mm
thick.
FLOOR
PROTECTOR*
D
500
mm
E
200
mm**
F
1000
mm
G
925
mm
*Cement
fibre
sheet
or
similar.
No
protection
is
required
if
the
unit
is
installed
on
a
non
‐
combustible
floor
(ex:
concrete).
**The
floor
protector
shall
extend
not
less
than
200
mm
from
each
side
of
any
ash
removal
or
fuel
loading
openings
unless
the
floor
protector
forms
an
abutment
with
a
wall
or
heat
shield
at
a
lesser
distance.