9.3.2 Charging switch-off when used in a motor vehicle.
Activating and deactivating
• Switch on the secondary light.
• Press button again and keep it pressed.
• With the button depressed, insert the portable lamp into the charging unit and keep
pressing the button until the LED signals the switchover.
9.4
Battery capacity test
Charging unit
• Connect to the supply voltage.
• The "Power" LED is lit.
• Insert the portable lamp.
Portable lamp
• Any switched-on LED will be switched off.
• A functional test will be carried out.
• The LED display shows information on the charging state or possible faults.
• Keep pressing the button until the LED display shows the battery test.
• The LEDs of the LED display are switched on and off one after the other.
Upon delivery, the function "Switch off charging operation in the event of
undervoltage" is active.
In case of undervoltage, the charging operation in the motor vehicle will be
interrupted.
The function can be deactivated and activated.
red
green green green green Description
Charging switch-off off
Charging switch-off on
WARNING
Danger when used in hazardous areas!
The explosion protection is impaired!
• Use the charging unit in safe areas only.
The test
• should be carried out once a year.
• takes up to 20 hours.
• should be carried out at room temperature.
The test is cancelled when:
• the portable lamp is removed from the charging unit.
• the button on the portable lamp is pressed.
• the main LED is defective.
• the power supply of the charging unit is interrupted.
• the supply voltage falls below the lower voltage limit.