The data collected on the J2K with Multi Media Card will open in a spreadsheet with the recorded on
calculated values displayed in the following format.
Column
Description
Range/Comment/Example
A
Date
DD.MM.YYYY
13:02:2006
(February
13,
2006)
B
Time HH:MM:SS
09:36:54 (9:36:54 AM)
C
O2 in vol.%
0.0 – 21.0
D
CO in ppm
0 - 4000
E
NO in ppm
0 – 4000 Standard, 0.0 – 300.0 Low NOx
F
NO2 in ppm
0 – 500 Standard, 0.0-50.0 Low NOx
G
SO2 in ppm
0 – 5000 (0 if SO2 sensor not installed)
H
CO w/ O2 correction applied
0.0-20.0 %
I
NO w/ O2 correction applied
0.0-20.0 %
J
NO2 w/ O2 correction applied
0.0-20.0 %
K
NOX w/ O2 correction applied
0.0-20.0 %
L
SO2 w/ O2 correction applied
0.0-20.0 % (0 if SO2 sensor not installed)
M
T.Gas in °C or °F
Exhaust Gas temperature w/ probe
N
T.Air in °C or °F
Ambient Air temperature at instrument
O
Draft in “ H2O
0.0 – 40.0 inches water gage
P
CO2
in
vol.%
0.0
–
25.0
Q
Efficiency in %
0.0 – 100.0
R
Losses in %
0.0 – 100.0
S
Excess air (Lambda)
1.00 = 0.00% excess air, 1.20 = 20% excess air
T
Dew point in °C or °F
U
Poisoning
index
V
O2 (gas channel check) in vol.% 0.0 – 21.0
W
CO (gas channel check) in ppm related to 0,0 vol.% O2
X
CO (gas channel check) in ppm Measured value
Y
O2 (check if O2 mixed) in vol.% 0.0 – 21.0
Z
T. Boiler
0 - 999
AA
T. Sensor (internal sensor temp) 0 – 99 F
AB
O2 Correction
0.0 – 21.0 (programmed by user)
AC
Unit of measure
0=ppm; 1=mg/m3; 2=mg/kWh; 3=mg/MJ
AD
O2 Correction
N= O2 correction value.
AE
Fuel type number
Refer to instrument fuel choices
AF
Fuel type text
Refer to instrument fuel choices
AG
Soot Test # 1 value
0.0 – 9.9
AH
Soot Test # 2 value
0.0 – 9.9
AI
Soot Test # 3 value
0.0 – 9.9
AJ
Oil trace
0=no; 1=yes;