ecom GmbH

Am Großen Teich 2
D-58640 Iserlohn 
[email protected]
www.ecom.de

Phone:  +49 2371 945-5
Fax:    +49 2371 40305

Содержание ecom-AK

Страница 1: ...OPERATION MANUAL English Status Sep 2021 Version ecom AK ...

Страница 2: ...tify the make and the model of the following firing automats Siemens Landis Staefa LMG LMO LME Honeywell Satronic Dxx Dxx N SH SH N SG SG N DKO 970 DKO 972 DKO 974 DKO 976 DKO 992 DKW 972 DKW 976 DMO 976 DIO 974 DIO 976 DKG 970 DKG 972 DLG 974 DLG 976 DMG 970 DMG 971 DMG 972 DMG 973 DMG 991 DVI 980 DVI 982 SH 11x SH 21x SH 12x SH 23x SG 11x SG 51x SG 13x DKO 970 N DKO 972 N DKO 974 N DKO 976 N DKO...

Страница 3: ...ors may only be done by qualified specialists CAUTION Damage of the Electricity Moisture or frost can damage the electronics Do not store the unit in moist rooms or at sub zero temperatures CAUTION Malfunction of the Readout Process Exposure to strong light can disturb the readout process Protect ecom AK from strong light ...

Страница 4: ...etting Key 2 Housing Head 4 Display 5 4 3 2 1 Set Language NOTICE ecom AK starts after about 5 s in the selected language 1 Hold down the setting key until Language English on the display appears 2 Use the setting key to select the required language ...

Страница 5: ...mode 1 Set ecom AK to the interference suppression button 2 Enable ecom AK by pressing the setting key 3 ecom AK searches for automat information 4 ecom AK switches off after 2 minutes if it does not detect any signal CAUTION Malfunction of the Readout Process Exposure to strong light can disturb the readout process Protect ecom AK from strong light Readout Firing Automat in Operating Position Pre...

Страница 6: ...with operation voltage at fault time of fault shut down are displayed in 3 second intervals Siemens Display of the current and last 5 faults with number of burner starts when the fault occurred 5 Statistics Satronic Display Total number of faults number of extraneous light faults number of no flame after safety time faults number of flame failure faults total number of burner starts number of burn...

Страница 7: ...off the housing head to the front 3 Remove the circuit board 4 Change batteries 5 Reassemble ecom AK in reverse order Connection with the PC NOTICE A special cable is required for the connection to the PC PC interface RS232 data cable AK PC or PC interface USB Data cable AK PC adapter cable RS232 USB 1 Start the programme with Start Programmes AKPC 2 Select COM port from the Setup menu 3 Select CO...

Страница 8: ...c burner control are displayed on 2 pages in the software 5 6 7 8 9 4 3 2 1 1 Oil preheater 4 Actual flame signal 7 Valve 2 2 Engine is running 5 Flame signal min 8 Valve 1 3 Ignition is active 6 Flame is detected 9 Operating voltage ...

Страница 9: ...esignation 5 Current error 9 Print data 2 Total number of burner starts 6 Error history 10 Copy data to clipboard 3 Error statistics 7 Active burner components 4 Control times firing automat 8 Save data to text file 8 9 10 ...

Страница 10: ...ssible with cable and not by radio Automatic burner control in Set diagnostic mode Only necessary for Siemens automatic burner control units Technical Data Power Supply 2x Rechargeable Battery Typ AA 1 2 V or 2x Battery Typ AA 1 5 V Power Consumption Approx 100 mA Storage Temperature 20 C 50 C Operating Temperature 20 C 50 C Size 88 mm x 41 mm x 32 mm NOTICE Subject to technical changes Status 09 ...

Страница 11: ...orised centre NOTICE On request we take back old appliances and dispose of them in an environmentally friendly way Consumables Spare Parts You can find consumables or spare parts in our webshop at www shop ecom de NOTICE To ensure the accuracy of your measuring device we recommend an annu al inspection by an authorised ecom partner In case of heavy use shorter inspection intervals should be chosen...

Страница 12: ...ecom GmbH Am Großen Teich 2 D 58640 Iserlohn info ecom de www ecom de Phone 49 2371 945 5 Fax 49 2371 40305 ...