6
- Do not disassemble the device.
- Use only the original battery module “Ex-BPC 41“.
- Do not dismount the battery pack inside hazardous-area.
- It is not allowed to carry dismounted battery packs into the hazardous-area.
- The battery module may only be charged outside the hazardous-area and only by using the Safety box “SBH 07”.
- The battery module may only be charged in a temperature range of 0 - 45 °C.
- The data connection is only allowed outside the hazardous area and only allowed by using the Safety box “SBH 07”.
- For charging or data transfer first connect the Safety box “SBH 07” to the phone, then connect the the Safety
box “SBH 07” to an USB-A socket. If done differently, the Safety box “SBH 07” may get harmed.
- When changing the battery (outside hazardous-area), ensure that both the device and the battery module
are clean of dust and dirt.
- Only accessories approved by ecom instruments GmbH may be used. See relevant product page at www.
ecom-ex.com.
- The wired headset may not be used inside potentially explosive areas.
- Only accessories specifically certified for use with this equipment inside potentially explosive areas may be
connected, such as the C-C550 IS Remote Speakter Microphone certified under Intertek Authorization to
mark no. 3153168.
- It must be ensured that the device is not taken into zones 0 or 20.
SHW_SONIM_XP_STRIKE_PA000457_EN_ES.indd 6
30.07.13 14:22