NOTICE!
Supply compressed air to (pressurize) the system only after all connections
to the spraying air valve, the pressure vessel and the compressed air
connection have been completely and securely made.
6.5.1
Guideline values
Data
Value Unit
Viscosity up to 150 mPas (cp):
0,02 (0,2) MPa (bar)
Viscosity up to 2000 mPas (cp):
0,02 (0,2)
- 0,08 (0,8)
MPa (bar)
It should be ensured at first ever charging of the metering unit that the product reaches
the spraying valve with no bubbles contained in it. For this reason, the spraying valve
must be
held vertically upward
while the
‘MAN’
button or (in continuous operating
mode) the foot switch is actuated simultaneously.
Continue conveying approx. 1 cm³ after the product escapes from the spraying valve.
For spray application, the control unit should be reset to Automatic mode of operation and
the required metered quantity set by modifying metering time.
Installation and start-up
24
417101439 Rev. 2-09.2019