6
Installation and start-up
Personnel:
n
Specialist
n
Qualified electrician
n
Mechanic
n
Service personnel
6.1
Installation
6.1.1
Electrical connections
6.1.1.1 Setting of mains voltage
CAUTION!
The device has been pre-set to 230 V mains voltage!
If the mains voltage is 115 V, rotate the voltage selector (pos. 1) by 180
degrees and replace the fuse (pos. 2) with the 115 V (250 mA) fuse
included in the package.
1
2
3
Fig. 4: Setting of mains voltage
1
Voltage selector
2
Fuse
3
Cover, with viewing window
Voltage selection:
1.
Remove the cover (pos 3)
2.
Turn the voltage selector (pos. 1) under the cover through 180° until the required
voltage becomes visible (stamped on the selector)
3.
Replace the cover (pos. 3). The voltage set can be seen through the viewing window
of the cover (pos. 3).
Installation and start-up
21
417101439 Rev. 2-09.2019