9. Specifi cations
The most important specifi cations are placed on the model tags of the Booster and the pump respectively.
Booster 6 Booster 6 Booster 12 Booster 12 Booster 24
Floor Wall Floor Wall
Max. working pressure (bar)
25 25 25 25 25
Pump pressure (bar)
21 21 21 21 21
Water fl ow (l/min.)
10-100 10-100 10-200 10-200 10-400
Min. water supply (l/min)
100 100 200 200 400
Supply pressure (bar)
2-4 2-4 2-4 2-4 2-4
Min. water fl ow at start
3 3 3 3 -
380 – 415 V, 50 Hz*
Power consumption (KW)
4 4 7.5 7.5 15
Control voltage (V)
24 24 24 24 24
Motor overload protection (A)
8 8 15.2 15.2 2x 15.2
Protection (A)
25/20 time-lag 20/16 time-lag 25 25 63
Weight (kg)
70 95 140 150 230
Dimension (H x W x D)
1270x445x490 1326x600x310 1400x500x480 1426x600x310 1400x1060x800
380 – 480 V, 60 Hz*
Power consumption (KW)
5.5 5.5 11 - 22
Control voltage (V)
24 24 24 - 24
Motor overload protection (A)
10.8 – 9 10.8 – 9 21.4 – 17.4 - 2 x 21.4 – 17.4
Protection (A)
25/20 time-lag 25/20 time-lag 35 - 63
Weight (kg)
96 105 174 - 289
Dimension (H x W x D)
1310x478x490 1326x600x310 1460x510x490 - 1460x1060x800
*) Always check the actual voltage on the motor’s sign.
Sound Pressure Level L
pA
measured in accordance with ISO 11202
(DISTANCE 1m] [FULL LOAD]: Below 70 dB(A)