![Ecolab 9223-1070 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ecolab/9223-1070/9223-1070_installation-and-operation-manual_2354452009.webp)
7
Mount Apex2 I/O Enclosure
Attach the Apex2 I/O mounting bracket to the wall using the supplied screws
and plastic wall anchors. The installation should be secure, neat, and level. See
Figure 4-4
Inductive Probe Installation
For optimal equipment performance and reliability choose a location that is:
• A minimum of 2” (5 cm) from the tank bottom, side wall, overflow piping,
etc.
• As far as possible (2” [5 cm] minimum) from heater elements or coils
• Protected from physical hazards.
• Always underwater, with entire Probe constantly submerged, particularly
on shallow tank machines.
Before drilling the hole in the wash tank, identify and avoid any obstructions
both inside and outside the wash tank.
Installations Steps
1. Drill/Cut a 7/8” (22 mm) hole into the wash tank wall.
2. Install the rubber sealing washer onto the probe (over the threads and
against the flange on the probe).
3. From the inside of the tank, route the wire through the hole until the
probe is against the wall of the wash tank. Secure the Inductive Probe
to the wash tank using the provided retaining nut with the O-Ring against
the outside surface of the tank wall. The nut end of the Inductive Probe
must be on the outside of the machine wall, refer to Figure 4-5.
!
WARNING
Figure 4.4
Figure 4.5
Содержание 9223-1070