![Ecolab 9223-1070 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/ecolab/9223-1070/9223-1070_installation-and-operation-manual_2354452031.webp)
29
Adjust Dispensing: Door Timed
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
1
Set duration of detergent dispense per rack:
Range: 1-30 seconds, interval of 0.1 seconds
Default: 2.5 seconds.
Set frequency of detergent dosing:
Range: 1-10 racks, interval of 1 rack
Default: 1 rack
Adjust Detergent Valve Run Time
Adjust Detergent Dose Interval
Adjust Initial Detergent Charge
Adjust Detergent Valve Run Time
Adjust Detergent Dose Interval
Adjust Initial Detergent Charge
1
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
Set the delay time for starting the third product pump after receiving
a rinse signal:
Range: 0-30 second, interval 1 second
Default: 2 seconds
1
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
00:00:00 pm
Logout
View Information
Adjust Dispensing
Diagnostics & Troubleshooting
Setup System
2.5 Seconds
Set the initial detergent charge after machine fill
Range: 1-999 seconds, interval 1 second
Default: 37 Seconds
Adjust Detergent Valve Run Time
Adjust Detergent Dose Interval
Adjust Initial Detergent Charge
37 Seconds
1 Racks
Set the rinse pump speed
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
Prime the rinse line for 30 seconds at the programmed Rinse
Pump Speed.
Adjust Rinse Pump Speed
Adjust Rinse Pump Limit
Adjust Rinse Start Delay
Adjust Pump Prime
Set the rinse aid pump run time limit per rack:
Range: 0-50 seconds, increments of 1 second
Default: 15 seconds
Adjust Rinse Pump Speed
Adjust Rinse Pump Limit
Adjust Rinse Start Delay
Adjust Pump Prime
Set the delay time for starting the rinse pump after receiving a
rinse signal:
Range: 0-30 second, interval 1 second
Default: 2 seconds
Adjust Rinse Pump Speed
Adjust Rinse Pump Limit
Adjust Rinse Start Delay
Adjust Pump Prime
Adjust Rinse Pump Speed
Adjust Rinse Pump Limit
Adjust Rinse Start Delay
Adjust Pump Prime
01
Adjust Detergent
Adjust Rinse Aid
Adjust Third Product
Back
15.0 RPM
15 Seconds
2 Seconds
Press start to begin priming
Set the third product pump speed:
Range: 8-30RPM, increments of 0.5RPM
Default: 15RPM
Default product selection: None
Adjust Third Product Pump Speed
Adjust Third Product Pump Run Time
Adjust Third Product Pump Start Delay
15.0 RPM
Set the third product pump run time limit per rack:
Range: 0-50 seconds, increments of 1 second
Default: 15 seconds
Adjust Third Product Pump Speed
Adjust Third Product Pump Run Time
Adjust Third Product Pump Start Delay
15 Seconds
Adjust Third Product Pump Speed
Adjust Third Product Pump Run Time
Adjust Third Product Pump Start Delay
2 Seconds
Содержание 9223-1070
Страница 21: ...19 v Alarm Priority...