Assembly sequence (Ref. fig. 32 and 33)
A) Mount the insulation (pos. 1) of the boiler body and secure
the 2 edges with the elastic straps (pos. 2) supplied in the
accessory box, hooking them to the external fabric part of the
insulation.
Perform a sufficient cut on the top part near the bulb holders.
B) Position the side panels (pos. 3a, 3b and 4a, 4b) with the lower
bend inside the L-shaped profile at the base of the boiler body
and hook the upper part to plate junction profiles.
To determine which is the right side and which is the left side,
refer to the cable gland plates on the front panels (pos. 5): they
must face the front of the boiler.
C) Mount the bottom rear panel (pos. 8).
D) Fit the upper rear panel (pos. 9).
E) Rotate the cover of the panel board frontwards after having
removed the two screws on the side and insert the electric
inlet cables and the outlet probe capillaries through the slots
at the base.
Fit the panel board to the upper panel (pos. 11).
Fit the upper panel (pos. 11), complete with panel board, to
the two sides of the casing.
F) Insert the bulbs of the instruments into the conduits as
indicated in fig. 33 and wire the panel board to the power line,
to the burner and to any pumps, etc.
Close the cover of the electric control board.
Guide the burner plug through the side plate (pos. 5) on the
preferred side and secure the cable with the cable gland
supplied.
Fasten the plates (pos. 5) to the sides of the casing.
Secure the electric cables coming out from the rear of the
boiler with the cable clamps, tightening them moderately.
G) Fit the upper longitudinal panels (pos. 12 and 13) to the
sides of the casing.
fig. 32