background image

 

Once the head is included into MyVirtuoso Home, it can 
be mounted onto the radiator valve.

 

 
b. Mounting 

1

.

 

The display will show the "PRP" message until 

the  mounting  position  is  achieved,  after  which 

"INS" and the icon 

 appear. The LED will blink 

green,  pending  confirmation  by  the  user.  
 

2

.

 

If  necessary,  locate  an  appropriate  adapter 

and 

mount 

it 

onto 

the 

valve.

 

 
3. 

Place the TTDZ2 on the ring and screw it until 

it  reaches  the  correct  position.  For  the  duration 
of  the  process,  the  message  "INS"  will  remain 
visible on the display. 

 
4. 

If  the  installation  is  successful,  the  LED  will 

remain green for 5 seconds, while the display will 
show the default set temperature. 
 

5. 

If  the  assembly  fails,  the  display  will  show 

"ER1", the LED will remain red and a notification 
will be sent to the APP. 

 

 
 
 
 

Содержание TTDZ2

Страница 1: ...1 TTDZ2 Digital Thermostatic Head Instruction manual...

Страница 2: ...2 Summary 1 INTRODUCTION pag 3 2 DESCRIPTION AND PRODUCT SPECIFICATIONS pag 4 3 PACKAGE CONTENTS pag 8 4 INSTALLATION pag 8 5 MODE pag 11 6 DISPOSAL pag 13 7 WARRANTY pag 14...

Страница 3: ...3 1 Introduction SmartDHOME thank you for choosing this TTDZ2 digital thermostatic head for radiator control This device is Z Wave certified and is compatible with the MyVirtuoso Home gateway...

Страница 4: ...diators Activating or deactivating zones according to actual needs saves energy Technical specifications Batteries 2x1 5V AA alkaline class III Battery life Up to 2 years Display type LC backlit displ...

Страница 5: ...ncreases the temperature by 0 5 C increments until required temperature is reached and Press both simultaneously for 3 seconds Enables disables the Child Protection mode Press once Action Confirmation...

Страница 6: ...e update Red LED Stay fixed for 5 seconds An operation has failed Red LED Stay fixed An error has occurred Refer to the manual to check the type of error Green LED Blinking Waiting for confirmation fr...

Страница 7: ...is visible the link works correctly Otherwise the connection was lost It lights when the display shows the Z Wave node ID Visible when the battery is below 15 charge Child protection mode is active V...

Страница 8: ...w INC and the green LED will flash while waiting for confirmation from the user 2 Once the inclusion is started the header display will show a countdown within which the operation is to be completed 3...

Страница 9: ...necessary locate an appropriate adapter and mount it onto the valve 3 Place the TTDZ2 on the ring and screw it until it reaches the correct position For the duration of the process the message INS wil...

Страница 10: ...e LED will remain red for 5 seconds d Reset to factory settings 1 Remove the batteries from the head and press the button Holding it down reinsert the batteries The display will now show RES Release t...

Страница 11: ...re it will take 5 seconds before it is registered as the new desired temperature The minimum setting value is 8 0 C while the maximum value is 28 C If you try to overcome these limits the temperature...

Страница 12: ...the key while the display shows ON The valve will open for 5 minutes This mode is designed to quickly increase room temperature f Child protection mode Hold down the and keys simultaneously for 3 sec...

Страница 13: ...ion about available collection systems If electrical appliances are disposed of in landfills or in inappropriate places hazardous substances can escape into groundwater and enter the food chain damagi...

Страница 14: ...14 7 Warranty Visit the link http www ecodhome co uk warranty and repairs SmartDHOME Srl www ecodhome com info smartdhome com Rev 07 2017 P N 01335 1013 00...