background image

10 

 

c. Exclusion 

1

.

 

Set  the  MyVirtuoso  Home  gateway  into 

Exclusion mode and hold down the key 

 for 5 

seconds. The display will show "LEA". 
 

2

.

 

If  the  exclusion  is  successful,  the  display  will 

show the  number 0  as the  Z-Wave  node  ID  and 
the  LED  will  remain  green  for  5  seconds.

 

 
3. 

In  the  exclusion  phase,  the  display  will  show 

the Z-Wave node ID and the LED will remain red 
for 5 seconds. 

 
d. Reset to factory settings 

1

.

 

Remove the batteries from the head and press 

the  button 

.  Holding  it  down,  reinsert  the 

batteries:  The  display  will  now  show  "RES". 
Release the key: The LED will blink green waiting 
for 

confirmation 

from 

the 

user. 

 

2

.

 

Press  the  button 

  again:  the  display  will 

show "DEF" and the LED will remain green for 5 
seconds, indicating the success of the reset. 

 

5.    

Mode 

The  TTDZ2  digital  thermostatic  head  can  be  used  in  several 
modes,  which  can  be  set  up  locally  and  /  or  through 
MyVirtuoso Home APP. 

Содержание TTDZ2

Страница 1: ...1 TTDZ2 Digital Thermostatic Head Instruction manual...

Страница 2: ...2 Summary 1 INTRODUCTION pag 3 2 DESCRIPTION AND PRODUCT SPECIFICATIONS pag 4 3 PACKAGE CONTENTS pag 8 4 INSTALLATION pag 8 5 MODE pag 11 6 DISPOSAL pag 13 7 WARRANTY pag 14...

Страница 3: ...3 1 Introduction SmartDHOME thank you for choosing this TTDZ2 digital thermostatic head for radiator control This device is Z Wave certified and is compatible with the MyVirtuoso Home gateway...

Страница 4: ...diators Activating or deactivating zones according to actual needs saves energy Technical specifications Batteries 2x1 5V AA alkaline class III Battery life Up to 2 years Display type LC backlit displ...

Страница 5: ...ncreases the temperature by 0 5 C increments until required temperature is reached and Press both simultaneously for 3 seconds Enables disables the Child Protection mode Press once Action Confirmation...

Страница 6: ...e update Red LED Stay fixed for 5 seconds An operation has failed Red LED Stay fixed An error has occurred Refer to the manual to check the type of error Green LED Blinking Waiting for confirmation fr...

Страница 7: ...is visible the link works correctly Otherwise the connection was lost It lights when the display shows the Z Wave node ID Visible when the battery is below 15 charge Child protection mode is active V...

Страница 8: ...w INC and the green LED will flash while waiting for confirmation from the user 2 Once the inclusion is started the header display will show a countdown within which the operation is to be completed 3...

Страница 9: ...necessary locate an appropriate adapter and mount it onto the valve 3 Place the TTDZ2 on the ring and screw it until it reaches the correct position For the duration of the process the message INS wil...

Страница 10: ...e LED will remain red for 5 seconds d Reset to factory settings 1 Remove the batteries from the head and press the button Holding it down reinsert the batteries The display will now show RES Release t...

Страница 11: ...re it will take 5 seconds before it is registered as the new desired temperature The minimum setting value is 8 0 C while the maximum value is 28 C If you try to overcome these limits the temperature...

Страница 12: ...the key while the display shows ON The valve will open for 5 minutes This mode is designed to quickly increase room temperature f Child protection mode Hold down the and keys simultaneously for 3 sec...

Страница 13: ...ion about available collection systems If electrical appliances are disposed of in landfills or in inappropriate places hazardous substances can escape into groundwater and enter the food chain damagi...

Страница 14: ...14 7 Warranty Visit the link http www ecodhome co uk warranty and repairs SmartDHOME Srl www ecodhome com info smartdhome com Rev 07 2017 P N 01335 1013 00...

Отзывы: