TERMS OF WARRANTY 

 

Main and auxiliary equipment and all components used in

 

ECODENSE WT-S DHW 45 L, 

ECODENSE WT-S DHW 45 H, ECODENSE WT-S DHW 45 XH, ECODENSE WT-S DHW 55 L, 
ECODENSE WT-S DHW 55 H, ECODENSE WT-S DHW 55 XH, ECODENSE WT-S DHW 65 L, 
ECODENSE WT-S DHW 65 H, ECODENSE WT-S DHW 65 XH, Condensing Boilers are guaranteed 
for 1 year by 

TERMO ISI S

İ

STEMLER

İ

 A.

Ş

starting from the date of commissioning under the 

maintenance, adjustment, operating conditions and relevant mechanic, chemical and thermal effects 
explained herein. 
 

 
Please note that this warranty is only valid if the device(s) is commissioned and maintained by our 
authorized services. 

 

 
Our  company  reserves  the  right  to  make  any  modifications  on  the  product  and  all  instructions 
thereof for improvement purposes.  

 
 

2.1.

 

Out of Warranty Conditions 

 

 

Any  damage  arising  out  of  or  in  relation  to  customers’  non-compliance  to  their  responsibilities 

with regards to installation, commissioning, operation and maintenance, 

 

Any damage arising out of or in relation to commissioning, repairs and maintenance carried out by 

unauthorized services,

 

 

Any damage that may occur during transportation or storage of the product,

 

 

Not preserving the product in its original packaging until the installation stage, 

 

Incorrect and poor electrical connections, Failures due to incorrect voltage applications, frequent 

repetition of voltage fluctuations, 

 

Any  damage  that  may  occur as  a  result  of  incorrect  fuel  usage  or, foreign  substances in  the  fuel 

used or using of the product without any fuel,

 

 

Any  damage  that  may  occur  due  to  foreign  particles  entered  into  the  product  during  installation 

and operation, 

 

Failures due to incorrect device selection,

 

 

Any damage to unit due to natural disasters,

 

 

Devices without any warranty certificates,

 

 

Warranty Certificates without the stamp and signature of the authorized dealer or service,

 

 

 Devices with any falsification on the warranty certificate or without an original serial number.  

 

The  risks  during  transportation  of  device  under  the  responsibility  of  customer  belong  to  the 

customer.

 

 

Presence of misuse faults are indicated in the reports issued by authorized service stations or our 

authorized  agent,  dealer,  representative  or  our  factory  in  case  of  unavailability  of  authorized 
service stations.

 

 

Customers  may  apply  consumer  protection  arbitrator  committee  with  regards  to  this  report  and 

request for an expert report.

 

 

Содержание WT-S DHW 45 H

Страница 1: ...NSTALLATION OPERATING AND MAINTENANCE MANUAL ECODENSE WT S DHW 45 L ECODENSE WT S DHW 45 H ECODENSE WT S DHW 45 XH ECODENSE WT S DHW 55 L ECODENSE WT S DHW 55 H ECODENSE WT S DHW 55 XH ECODENSE WT S D...

Страница 2: ...y warnings thoroughly before the use of the device in order to ensure safe cost effective and environmental friendly use If you encounter any issue that is not explained clearly in this manual or you...

Страница 3: ...12 8 INSTALLATION 13 8 1 General Controls 13 8 2 Assembly of Condensing Fluid Drain 14 9 ECODENSE CONTROL INSTRUCTIONS BEFORE START UP 15 9 1 Control Panel Description 16 9 2 Display Description 16 9...

Страница 4: ...riptions Important information and useful hints Warning of danger to life or property Warning of electrical voltage Product handling information GAZ HATTINI TEM ZLEY N Z CLEAN GAS LINE Clean the gas l...

Страница 5: ...ty elements should be carried out only by the manufacturing company The device should never be used by children mentally handicapped and inexperienced persons Children must not be allowed to play with...

Страница 6: ...en to the atmosphere and Bird cage should be installed in order to prevent any Bird foreign body entrance a The build up of toxic explosive gas mixtures in the boiler room b Combustion with insufficie...

Страница 7: ...es Any damage that may occur during transportation or storage of the product Not preserving the product in its original packaging until the installation stage Incorrect and poor electrical connections...

Страница 8: ...04 12 2020 Rev 00 7 3 CONDENSING BOILER GAS FLUE GAS AND HEATING WATER SCHEMA WT S DHW SERIES...

Страница 9: ...04 12 2020 Rev 00 8 4 CIRCUIT SCHEMES WT S DHW SERIES...

Страница 10: ...rdness ppm F French VDI German Single Boiler 0 50 kW 250 25 14 Single Boiler 50 200 kW 110 11 6 16 Volume to capacity ratio of water in circuit must be higher than 20 I kW Total volume of first filled...

Страница 11: ...04 12 2020 Rev 00 10 6 TECHNICAL DATA 6 1 Capacity Table...

Страница 12: ...according to the product standards at the time of expansion of the smoke release system when the condensing boiler operates at the maximum heating power MODEL W mm H mm L mm Boyler Tank Volume L WT S...

Страница 13: ...12 7 CONDENSING BO LER HANDLING INFORMATION Prevent strong impacts on top of the product and vibration while handling the product Do not leave the product in wet environment Device must be shipped in...

Страница 14: ...connections are made with pipes confirming to the standards and that there is no leakage on these connections Ensure that the electric connections are proper Clean the inside of fuel line thoroughly...

Страница 15: ...nal effect like frost etc Drain parts must be plastic 3 Boiler condensing outlet must be at least 13 mm Condensing drain must not be changed or clogged after assembly Clogging of condensing drain caus...

Страница 16: ...complies with boiler operation instructions In situations where gas pressure is higher than required pressure a regulator must be used 9 Ensure that sensors on boiler feed and circuit outgoing return...

Страница 17: ...CH setpoint adjustment K6 DHW setpoint adjustment K3 OFF Info mode selection K7 DHW setpoint adjustment K4 RESET mode 9 2 Display Description S1 DHW mode S9 Solar mode S2 Reset request S10 S17 Water p...

Страница 18: ...g boiler is worked on DHW mode and tap symbol will be flashing when condensing boiler works at DHW mode Because of the DHW priority even if the appliance is operating at CH condensing boiler will swit...

Страница 19: ...04 12 2020 Rev 00 18 10 ELECTRICAL DIAGRAM AND RELATED CONNECTIONS WT S DHW...

Страница 20: ...04 12 2020 Rev 00 19...

Страница 21: ...04 12 2020 Rev 00 20...

Страница 22: ...the connections of the related terminals in the panel box as shown in the illustration below Closure of Room Thermostat contact generates a heat demand in CH mode If the room thermostat is not connec...

Страница 23: ...capacities again and adjust combustion parameters precisely by following above steps After adjustment of parameters are finished close all measurement points as they will be leak proof Flue gas emiss...

Страница 24: ...bolts of the boiler Tighten loose bolts After starting the condensing boiler and making required adjustments perform flue gas emission measurement and check if there is an ideal combustion 13 2 Seaso...

Страница 25: ...de expected bounds meaning a problem on electronic components E09 Valve feedback error The valve feedback doesn t respect controller commands E12 EEPROM integrity lockout The EEPROM check fails The da...

Страница 26: ...Shaky activation of burner Gas pressure Combustion parameters Check the gas pressure and combustion parameters No combustion after ignition Electrode Ionization Check the position state of the electro...

Страница 27: ...YE Tel 90 216 442 93 00 Fax 90 216 370 45 03 Factory Contact Details T rkg c OSB B lent Ecevit Bulvar No 11 ORLU TEK RDA T RK YE Tel 90 282 685 44 80 81 Fax 90 282 685 42 09 You can also reach us thro...

Страница 28: ...04 12 2020 Rev 00 27 17 NOTES Please record and forward your measurements and observations to us www ecodense com...

Отзывы: