Troubleshooting
Problem
No air delivery from indoor unit.
Moisture on air outlet vent.
Troubleshooting
●
In HEAT mode, when the indoor temperature is
very low, air delivery will be delayed for up to 5
minutes.
●
In HEAT mode, when the outdoor temperature
is low or high humidity, frost may form on the
outdoor heat exchanger. This will require
defrosting before air delivery; The defrosting
can take up to 20 minutes.
●
During the defrosting, water and vapor is
produced so condensation will occur
.
●
In dehumidifying mode, indoor fan will stop, in
order to avoid condensed water to be vaporized
again. The air delivery is delayed during this
action.
●
If unit is running in high humidity condition for
a long time, the moisture will be condensed
on the air outlet grill and drip off.
Immediately stop all operations and plug out,
contact the dealer in following situations.
There is harsh sound during operation.
Terrible odours are emitted during operation.
Water is leaking in the room.
Air switch or protection switch often breaks.
Water spillage into unit.
There is an abnormal heat in power supply cord
and power plug.
Stop running and pull out of the plug.