WARNING: Before operating your unit
Make sure the wiring is adequate for your unit.
Before you install or relocate this unit, be sure that the amperage rating of
the circuit breaker complies with the amp rating listed in Figure 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical
power to the unit; an extension cord will not.
Make sure that the Power Supply is
compatible with the air conditioner.
Safety Precautions
Input Rated Amp
WARNING
Electrical Shock Hazard
Always consult a qualified electrician regarding
the power supply to the appliance.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong outlet. Failure to
follow these instructions can result in death, fire, or
electrical shock.
Model
Power Supply
Input Rated Amp (Switch/Fuse)
Up to 12,000 Btu/h (3.5kW)
13A
18,000 Btu/h (5kW)
220-240V ~ 50Hz
20A
More than 18,000 Btu/h (5kW)
32A
Note : The supply voltage can not be less than the rate voltage of the air conditioner.
Warning
Installations must comply with the national wiring standards and conform to local authority regulations. Incorrect
installation could cause injury due to fire, electric shock, the unit falling or leakage of water. Consult the dealer from whom
you purchased the unit or a suitably qualified installer.
Do not modify or attempt the air conditioner without permission or instruction from the manufacturer.
Install the unit securely and ensure location of installation can bear the weight of the air conditioner.
Do not install or operate the air conditioner in areas where harmful or flammable gas are present.
Any maintenance on the air conditioner must only be carried out after disconnecting from the electric mains supply.
Any repairs must be carried out by a suitably qualified engineer.
Ensure the air conditioner is connected to an earthed power supply of the correct rating.
Do not unplug the air conditioner whilst in operation. Always use the control panel to start and stop the air conditioner.
Do not obstruct or cover the inlet and outlet grilles.
Do not use the air conditioner in a wet room, such as bathroom. Do not allow spray or pour water over directly onto the air
conditioner. Always handle the air conditioner with dry hands.
For the best cooling performance and highest energy efficiency
Keep the filter clean
Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing
and cleaning the filter can be found on page 12.
Provide good air flow
Make sure the airflow to and from the unit is clear. Your air conditioner blow the cold air out at the top of the unit, and takes in the
warm air from the room at the bottom. Airflow is critical to good operation. It is just as important on the outside of the building that
the airflow around the unit exterior is not blocked.
Unit placement
If your air conditioner can be placed in a window or wall that is shaded by a tree or another building, the unit will operate even more
efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit’s efficiency.
Insulation
Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk
around doors and windows.
Note: if you switch from Cool mode to Fan Only, and switch back to COOL mode, there is a three minute delay before the
compressor comes back on.