background image

0549-991-41---50a_2019.11.indd

ETS 42

0549-991/42a

Page 4 of 18

Operator manual

2 SAFETY

2.1 

Appropriate use

The swing door drive mechanism ETS 42 has been exclusively designed for operating swing doors. 

Any other use beyond these application limits is deemed inappropriate and inadmissible!

In the event of an inappropriate use of this system, the safety of the user may be jeopar dized 

and/or the installation be damaged. The manufacturer declines all responsibility for these inju

-

ries/damages!

2.2 

Safety notices

The present instructions uses the following symbols and notes in order to point out certain resi

-

dual dangers:

Warning:

Involving danger to life and limb.

Attention:

A situation where material could be damaged or the function impaired.

Note:

Hints which facilitate the work.

2.3 

Safety regulations

2.3.1 Principles

• Children

 must not be involved in the cleaning or user maintenance of this system. Very young 

children

 must not operate the system. 

Young children

 must only operate the system when 

under the close supervision of an adult. 

Older children and vulnerable persons may use this sys

-

tem safely once they have been shown, while under suitable supervision, how to use it approp

-

riately.

 

Highly vulnerable persons can only use the system safely when under close supervision, or if it 

is fitted with corresponding additional equipment that amply fulfils the scope-of-use standards 

of the norm EN 16005.

• The installation has been calculated, designed and manufactured on the basis of the latest 

state-of-the-art technology and the generally recognized safety-relevant rules and regulations. 

It may only be operated if it is in perfect condition, taking into account the specifications of the 

present manual. Any use beyond the defined application limits is inadmissible!

• The installation is to be operated and maintained in such condition that the safety is guaranteed 

at all times. An integral part of this condition is the appropriate use, the compliance with the 

operating conditions prescribed by the manufacturer, as well as the regular service (mainte

-

nance/checking).

• In order not to create any dangerous squeezing and shearing points, no structural modification 

must be made within the door surroundings, without prior authorization from 

ECO Schulte 

GmbH & Co. KG. Furthermore, it is important that no objects (such as furniture, pallets, etc.) be 

placed in the vicinity of the door.

• All further interventions on and modifications of the installation that are not described in the 

present instructions are forbidden!

Содержание ETS 42

Страница 1: ...0549 991 42a 2019 11 Swing door drive mechanism ETS 42 Operator manual Original Com no Pos Construction year Operator Operating place...

Страница 2: ...4 CONTROL 10 4 1 Program selector switch 10 4 2 Operating modes 10 4 3 D BEDIX option 11 4 3 1 Keys 11 4 3 2 Symbols 11 4 3 3 Operating modes 12 4 3 4 Display of the door position 12 4 3 5 Menu level...

Страница 3: ...s for a faultless and safe operation of the installation The operator manual must be completely read and understood 1 1 Target group All the activities described in the operator manual may only be car...

Страница 4: ...supervision how to use it approp riately Highly vulnerable persons can only use the system safely when under close supervision or if it is fitted with corresponding additional equipment that amply ful...

Страница 5: ...nue the operation of the installation 2 3 4 Malfunctions If any malfunctions occur which might be detrimental to the safety of the users the installation must be immediately taken out of operation It...

Страница 6: ...the programmed hold open time If the Push and Go function is enabled the door just requires a slight manual push upon which the drive unit carries out an automatic opening sequence The operating chara...

Страница 7: ...g movements of the door leaf are motorized The automatically opening is performed via opening elements The automatically closing starts as soon as the programmed hold open time has expired Function in...

Страница 8: ...of the door leaf This guarantees maximum protection during both opening and closing of the door Basically the instructions of the sensor manufacturer must always be observed when mounting the safety s...

Страница 9: ...W Motor power rating 100 W Power supply external comsumer 24 VDC 10 1 4 A Torque output shaft 56 Nm permanent 165 Nm max Lintel depth normal rods max 250 mm sliding rods pl 50 150 mm ps 50 150 mm Doo...

Страница 10: ...on expiration of the adjustable hold open time MANUAL 0 The drive mechanism and the control elements are switched off The door leaf can be manually opened The door leaf is closed by spring power from...

Страница 11: ...BEDIX can be connected per door installation 4 3 1 Keys C key Cancel Exit the menu Invalidate entry OK key Confirm the selection Confirm the entry Arrow keys Navigate within the menus Short simultane...

Страница 12: ...operating mode NIGHT from any random operating mode the internal radar will still remain active during the programmed time TdNigt EXIT OPEN The installation is opened and remains in the open position...

Страница 13: ...otected settings only made by the after sales service Display Description PARAMETER Setting the motional parameters CONFIG Setting the functionalities DOUBLE DOOR Setting the closing sequence and inte...

Страница 14: ...e right hand arrow key 4 3 6 Setting examples Changing the operating mode Select the desired symbol by means of the arrow key symbol starts flashing Confirm with the OK key frame bar switch over Prese...

Страница 15: ...E20 01 Error list see chapter Troubleshooting This sequence will be repeated until the error has been eliminated 4 4 KOMBI D BEDIX option In addition to the functions of the D BEDIX the KOMBI D BEDIX...

Страница 16: ...e included in the installation When the door wing is moved by hand can you hear any unusual grinding or screeching noi ses Check the function the free access to and identification of the emergency sto...

Страница 17: ...ter you will find further instructions about how you can try to eliminate the error or if it is necessary to contact the after sales service 6 2 Irregular functioning without error no Malfunction Anal...

Страница 18: ...sales sesrvice address see chapter 1 8 DISPOSAL OF THE INSTALLATION An ecologically acceptable disposal of the installation is ensured if the different materials are separated and recycled No particu...

Отзывы: