background image

22

FIG. 28

Cover

Prefilter

Cartridge

Manifold

Postfilter

Cartridge

RO

Cartridge

Turn to the left

to remove

Maintenance

PREFILTER / POSTFILTER MAINTENANCE

NOTE: It is recommended to replace the battery,

prefilter and postfilter cartridges at least every 6

months of product water use. Replace more often

if they begin to plug with sediment. 

The prefilter and postfilter are replaceable sediment

cartridges with activated carbon in their composition.

See Fig. 28. You must periodically replace the prefilter

and postfilter cartridge. This will  protect the RO mem-

brane from being destroyed by chlorine. It will also pre-

vent the filters from plugging with sediment.
You may notice a slower output of product water as

the prefilter and postfilter build up with sediment.

Replace the prefilter and postfilter cartridges when this

occurs. You should replace the battery whenever you

replace the cartridges.

RO MEMBRANE CARTRIDGE MAINTENANCE

The Reverse Osmosis cartridge is a tightly wound spe-

cial membrane. See Fig. 28. The membrane reduces

the 

dissolved

solids and organic matter. The life of the

Reverse Osmosis membrane cartridge depends mostly

on the pH and hardness of the supply water (see

Specifications). Cartridge life is shorter with higher pH.

For example, if supply water pH is from 6.8 to 7.7, the

cartridge may last for well over one year. However,

cartridge life may be as short as 6 months if the pH is

as high as 8.5 to 10. Higher pH weakens the cartridge

membrane and causes pin-hole leaks. It's time to

replace the Reverse Osmosis cartridge when the pro-

duction rate and/or quality of product water drops.

Product water may begin to taste different, indicating

solids and organics are passing through the Reverse

Osmosis membrane. See Reverse Osmosis cartridge

replacement.

REVERSE OSMOSIS CARTRIDGE REPLACE-

MENT

Complete the following steps to replace the cartridges.

NOTE: Do not remove manifold from mounts.

Flexing or twisting may damage the manifold.

1

. Remove (turn to the left) the prefilter cartridge from

the manifold to stop flow to the Reverse Osmosis

cartridge.

2

. Remove the Reverse Osmosis cartridge.

3

. Remove the postfilter cartridge.

4

. Discard the cartridges in a proper manner. 

5

. Install new cartridges in reverse order (post filter,

Reverse Osmosis and then prefilter). Turn cartridges

to the right to reattach to the filter heads. Do not

overtighten.

6

. Remove and replace the timer battery. See page 15.

7

. Purge the Reverse Osmosis system. See page 19

for instructions.

PREFILTER / POSTFILTER CARTRIDGE

REPLACEMENT

Complete the following steps to replace the cartridges.

NOTE: Do not remove manifold from mounts.

Flexing or twisting may damage the manifold.

1

. Remove the prefilter cartridge (turn to the left) from

the filter head. Then remove the postfilter cartridge.

2

. Discard the cartridges in a proper manner. 

3

. Install new cartridges in reverse order (postfilter first,

then prefilter). Turn cartridges to the right to re-

attach to the filter heads. Do not overtighten.

4

. Remove and replace the timer battery. See page 15.

5

. Purge the Reverse Osmosis system. See page 19

for instructions.

Содержание EP-RO25

Страница 1: ...F International against NSF ANSI Standards 42 58 See performance data sheet for details If you have any questions or concerns when installing operating or maintaining your reverse osmosis system call...

Страница 2: ...2 Step D Install Storage Tank 13 Step E Install Reverse Osmosis Faucet 14 15 Step F Connect Tubes 16 17 Step G Sanitize Pressure Test Purge System 18 19 How Your Reverse Osmosis System Works 20 21 Mai...

Страница 3: ...teration neglect freezing accident or negli gence and provided further that the Reverse Osmosis Drinking Water System is not damaged as the result of any unusual force of nature such as but not limite...

Страница 4: ...Arsenic Reduction This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine at the system inlet Water systems using an inline chlo...

Страница 5: ...carton Remove all items from your shipping carton Check all items against the packing list below Note any items lost or damaged in shipment Note any damage to the shipping carton Refer to the exploded...

Страница 6: ...drain water from the Reverse Osmosis system REMOTE INTERIOR LOCATION The Reverse Osmosis Filter Assembly and storage tank may also be installed in a remote interior location away from the Reverse Osmo...

Страница 7: ...n Soft water to Reverse Osmosis System Hard Water to House Main Shutoff Valve Storage Tank Water Meter Reverse Osmosis System To Faucet Floor Drain Air Gap see p 11 Typical Under Sink Installation All...

Страница 8: ...o planned location Check position of items and space required for proper installation Ensure tubes may be routed without kinking 3 Remove tank and filter from planned location and set aside NOTE You m...

Страница 9: ...nd do not permit the use of saddle valves If you live in the state of Massachusetts review plumb ing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installation INSTALL C...

Страница 10: ...r 1 Slowly disassemble the sink drain pipe between the sink P trap and the sink tailpiece See Fig 8 10 2 Clean the sink tailpiece to assure a leak tight fit 3 Install drain adapter directly onto the s...

Страница 11: ...e with an adequate length of tubing to reach the drain point Refer to Step F later in the manual on how to disconnect and connect tubing NOTE A flow control insert is located inside the elbow fitting...

Страница 12: ...assem bly See Fig 13 3 Hold the assembly up to the wall surface and mark locations for the hanger washers See Fig 13 Mount the unit high enough to allow room to change filters without taking the unit...

Страница 13: ...he top of the tank See Fig 14 2 Locate the tubing connector See Fig 14 Tighten the tubing connector onto the tank nipple 7 8 full turns being careful not to cross thread or overtighten 3 Do not connec...

Страница 14: ...ing space between the faucet and filter assembly 4 If drilling is needed drill a 1 3 8 diameter hole in the mounting surface IMPORTANT Drilling holes into countertops and sinks should only be performe...

Страница 15: ...aucet barb fitting on faucet See Figs 17 20 21 D Pull on the tubing to be sure it is held firmly in the fit ting 6 Mount the faucet body onto the faucet base 1 4 turn FAUCET ELECTRONICS Inside the fau...

Страница 16: ...collet until it engages the o ring See Fig 20 Continue pushing until the tube bottoms out against the back of the fitting See Fig 21 Do not stop pushing when the tube engages the o ring Failure to fo...

Страница 17: ...all the way into the fitting See Figs 20 21 5 Pull on the tube to be sure it s held firmly in the fitting CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1 Locate the 3 8 black tube at...

Страница 18: ...nitizing the system will be completed during the pressure test and purging steps on the following page NOTE The bleach must be removed from the system before drinking the water See purging instruction...

Страница 19: ...and do not per mit the use of saddle valves If you live in the state of Massachusetts review plumbing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installa tion PURGIN...

Страница 20: ...to the Reverse Osmosis faucet See Fig 27 The postfilter is an activated carbon type filter Any remaining tastes and odors are reduced from the product water Clean high quality drinking water is avail...

Страница 21: ...to the storage tank 5 Drain water with dissolved solids leaves the Reverse Osmosis membrane and flows to the drain 6 Faucet is activated 7 Processed water leaves the storage tank and flows to the post...

Страница 22: ...the cartridge membrane and causes pin hole leaks It s time to replace the Reverse Osmosis cartridge when the pro duction rate and or quality of product water drops Product water may begin to taste di...

Страница 23: ...and insert the o ring seal into the bottom of the port See Figs 30 31 3 Push the collet inward until it locks in place See Figs 30 31 CHANGE BATTERY To change battery complete the following steps 1 Re...

Страница 24: ...ilter or Reverse Osmosis membrane cartridges plugged with sediment Correction Replace the prefilter cartridge If rate does not increase replace the postfilter cartridge and Reverse Osmosis membrane ca...

Страница 25: ...7 Cause Tubing nicked Correction Remove tube from connection Remove nicked portion by cutting tube to shorter length Reinsert in connection See pages 16 17 If removing the drain line leave in place th...

Страница 26: ...26 Exploded View 22 21 18 17 16 15 19 20 14 13 11 1 2 3 4 8 9 7 5 6 1 4 red tubing 12 10 8...

Страница 27: ...4 2 of Key No 3 3 O ring Auto Shutoff Cover 2 req d 4 Check Assembly 7333145 Automatic Shutoff Kit incl Key No 7 4 of Key No 6 6 of Key No 5 5 Screw 6 req d 6 Washer 4 req d 7 Automatic Shutoff Cover...

Отзывы: