background image

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

TROUBLESHOOTING CHECKLIST (Caution: shut off power to pump)

PROBLEMS

PUMP DOES NOT RUN  

AND MAKES HUMMING 

SOUND 

 

 

 

 

PUMP RUNS BUT DOES  

NOT DELIVER WATER 

 

 

 

 

PUMP RUNS AND 

PUMPS 

OUT SUMP, BUT DOES  

NOT STOP

PUMP RUNS BUT ONLY 

DELIVERS A SMALL  

AMOUNT OF WATER 

 

 

 

 

FUSE BLOWS OR 

CIRCUIT BREAKER 

TRIPS WHEN 

PUMP STARTS 

 

 

 

MOTOR RUNS FOR A  

SHORT TIME, THEN 

STOPS

POSSIBLE CAUSES/SOLUTIONS

•  Line circuit breaker is off, or fuse is blown or loose 

•  Water level in sump has not reached turn-on level as indicated in  

 

  installation drawing. 

•  Pump cord is not making contact in receptacle. 

•  Float is stuck. It should operate freely in basin. 

•  If all of the above are OK, then the motor could be malfunctioning. 

•  Check if valve is installed backwards.  

 

 

 

 

  Arrow on valve should point direction of flow 

•  Discharge shut-off valve (if used) may be closed. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump is air-locked. Start and stop several times by plugging and  

 

  unplugging cord. Check for clogged vent hole in pump case.  

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fittings of the pump. 

•  Float is stuck in up position. Be sure float operates freely in basin. 

•  Defective float switch. Replace float switch. 

 

 

 

•  Pump is air-locked. Start and stop several times by plugging in and    

  unplugging cord. Check for clogged vent hole in pump case. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fitting of the pump. Inlet holes in pump base are clogged. 

  Remove pump and clean the strainer and openings. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump impeller is partially clogged with tar or paint, causing motor to   

  run slow and overload. Remove pump and clean. 

 

 
•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

 

•  Fuse size or circuit breaker may be too small. (must be 15 amps). 

•  Impeller or volute opening are fully or partially clogged.

  Remove pump and clean .  

 

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. Also clean the strainer if one is installed.

 

ELECTRICAL PRECAUTIONS

 

  Before servicing a pump, always shut off the main power breaker and  

 

  then unplug the pump. Make sure you are not standing in water and are 

wearing insulated protective sole shoes, under flooded conditions. Contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump 

removal

Содержание SUP54

Страница 1: ...Owner s Manual Submersible Manual Series Utility Pumps General Safety 2 Specifications 3 Installation 4 Troubleshooting 5 Warranty 6 TABLE OF CONTENTS SUP54 55 Manual SUP56 80 Manual ...

Страница 2: ...ot avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or moderate injury NOTICE indicates practices not related to personal injury Keep safety labels in good condition Replace missing or damaged safety labels General Safety Risk of burns Do not touch an operatin...

Страница 3: ... PERFORMANCE Capacity Cord Solids Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length Pumped SUP54 1 6 115 1 2 9 1680 20 Thermoplastic Thermoplastic 10 1 8 SUP55 1 4 115 1 3 3 1980 25 Thermoplastic Thermoplastic 10 1 8 SUP56 1 3 115 1 3 0 2880 25 Thermoplastic Thermoplastic 10 1 8 SUP80 1 2 115 1 3 3 3180 27 Thermoplastic Thermoplastic 10 1 8 1 1 4 NPT 6 06 6 06 10 3 ...

Страница 4: ...azardous 7 The following may cause severe damage to pump and will void the warranty a Using an extension cord b Cutting off the ground pin or using an adapter fitting c Working on pump or switch while plugged in d Removing motor housing unscrewing impeller or otherwise removing impeller seal e Running the pump continuously f Pumping chemicals or corrosive liquids g Pumping gasoline or other flamma...

Страница 5: ...y in basin Defective float switch Replace float switch Pump is air locked Start and stop several times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pump Inlet holes in pump base are clogged Remove pump and clean the strainer and openings Impeller or volute openings are fully ...

Страница 6: ...leged defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental applications General Terms and Conditions Limitations of Remedies You must pay all labor and shipping charges nece...

Страница 7: ...el des Propriétaires Manuel de l Utilitaire de Série des Pompes Submersibles SUP54 55 Manual SUP56 80 Manual Sécurité Générale 8 Spécifications 9 Installation 10 Dépannage 11 Garantie 12 CONTENTS DU TABLEAU ...

Страница 8: ...les étiquettes de sécurité manquantes ou endommagées Une pompe de puisard est un appareil électrique conçu pour fonctionner dans les environnements humides en soi TOUJOURS UTILISEZ UNE ATTENTION EXTREME lors d installer ou maintenir ce produit Besoin d Aide Téléphonez 1 877 326 3561 à l aide Ne Retournez pas au Magasin Sécurité générale Risque des brulures Ne touchez pas un moteur d opération Les ...

Страница 9: ...elleur du Cordon Pompés SUP54 1 6 115 1 2 9 1680 20 Thermoplastique Thermoplastique 10 1 8 SUP55 1 4 115 1 3 3 1980 25 Thermoplastique Thermoplastique 10 1 8 SUP56 1 3 115 1 3 0 2880 25 Thermoplastique Thermoplastique 10 1 8 SUP80 1 2 115 1 3 3 3180 27 Thermoplastique Thermoplastique 10 1 8 Pour les parts ou l aid téléphonez au Service de clientele de ECO FLO 1 877 326 3561 9 SUP54 55 SUP56 80 1 1...

Страница 10: ...r la broche de terre ou utiliser un raccord d adaptateur c Travailler sur la pompe ou l interrupteur lorque il est branché d Retirer le carter de moteur dévisser l impelleur ou autrement retirer le sceau de l impelleur e Faire fonctionner la pompe en continu f Pomper les produits chimiques ou liquides corrosifs g Pomper l essence ou d autres liquides inflammables 8 Tuyau en plastique PVC peut être...

Страница 11: ...t verrouillée à air Démarrez et arrêtez plusieurs fois par brancher et débrancher le cordon Vérifiez le venteau bouché dans la boîte de pompe La distance de pompage vertical est trop élevée Réduisez la distance ou changez des raccords de décharge de la pompe Les trous d entrée dans la base de la pompe sont bouchés Retirez la pompe et nettoyez la passoire et les ouvertures L impelleur ou les ouvert...

Страница 12: ...près l expiration de la garantie La garantie n est pas transférable et ne s applique pas aux produits utilisés dans des applications commerciales de location Les termes et les conditions généraux Les limitations de recours Vous devez payer tous les travaux et les charges nécessaires au remplacement du produit couvert par cette garantie Cette garantie ne s applique pas à ce qui suit 1 les actes de ...

Страница 13: ...Manual Del Usuario Sumergibles Bombas Manuales de Utilidad SUP54 55 Manual SUP56 80 Manual Seguridad general 14 Especificaciones 15 Instalación 16 Solución de problemas 17 Garantía 18 TABLA DE CONTENIDO ...

Страница 14: ... no se evita podría causar la muerte o lesiones graves indica un riesgo que si no puede evitarse puede provocar lesiones leves o moderadas AVISO indica prácticas no relacionadas con lesiones personales Mantenga las etiquetas de seguridad en buenas condiciones Reemplazar las etiquetas de seguridad faltantes o dañados Seguridad General Riesgo de quemaduras Notoque un motor en funcionamiento Los moto...

Страница 15: ...d Onguitud Sólidos Modelo HP Volt Ph Amps GPH at 0 Max Cabeza Construcción Impulsor de Cable Bombeados SUP54 1 6 115 1 2 9 1680 20 Termoplástico Termoplástico 10 1 8 SUP55 1 4 115 1 3 3 1980 25 Termoplástico Termoplástico 10 1 8 SUP56 1 3 115 1 3 0 2880 25 Termoplástico Termoplástico 10 1 8 SUP80 1 2 115 1 3 3 3180 27 Termoplástico Termoplástico 10 1 8 SUP54 55 SUP56 80 1 1 4 NPT 6 06 6 06 10 3 ...

Страница 16: ...n INSTALACIÓN b Cortando el conector de tierra o usando un adap tador apropiado c trabajando en la bomba o cambiando mientras está enchufado d Extracción de la carcasa del motor desenroscan do impulsor o retirar de otro modo el sello impul sor e Ejecución de la bomba de forma continua f los productos químicos de bombeo o líquidos corrosivos g la gasolina de bombeo u otros líquidos inflam ables 8 t...

Страница 17: ...s veces enchufando y desenchufando el cable Compruebe que el orificio de ventilación está obstruido en el caso de la bomba Distancia de bombeo vertical es demasiado alto Reducir la distancia o cambiar º accesorio de descarga de la bomba Los orificios de entrada en base de la bomba están obstruidos Saque la bomba y limpie el colador y aberturas aberturas del impulsor o la voluta están totalmente o ...

Страница 18: ...pronto como sea razonablemente posible No se aceptarán solicitudes de servicio si se recibe más de 30 días después del vencimiento de la garantía La garantía no es transferible y no se aplica a productos usados en aplicaciones comerciales alquiler Términos y Condiciones Generales Limitaciones de los Remedios Usted debe pagar todo el trabajo y cargas necesarias envío para reemplazar el producto cub...

Отзывы: