Notes on bringing the unit into the building
15
Minimum clearance dimensions required
Note:
To install the heating system properly and ensure economical operation, you need to make sure that mini-
mum clearance dimensions indicated below are observed when setting up the boiler.
In addition, make sure that legislation in your country is complied with relating to the minimum clea-
rance of the flue gas tube.
a
Min. clearance of flue gas con-
nection from wall or part of
building
450 mm
b
Min. clearance of side of boiler
from wall or part of building
200 mm
c
Min. clearance of front of boiler
from wall or part of building
700 mm
d
Min. clearance of side of burner
from wall or part of building
300 mm
e
Min. room height
1950 mm
Note:
Legislation in your country must be observed!
Placement of rubber plates
The pellet heating boiler must be placed on the supplied
rubber plates.
Installation Manual Easypell 16 — 32kW