N.  Frequently Asked Questions

CONTACT YOUR DEALER

 for additional information 

regarding operation and troubleshooting. 

Visit www.heatilator.com to find a dealer.

What causes my glass to become dirty?

If the glass has white ash build up it is normal and the 

glass should be cleaned. If it is a black soot build up airflow 

thru the unit may be restricted.  The most often cause is 

overdue maintenance and cleaning.  See “Maintaining and 

Servicing Appliance” in the owner’s manual.

How can I get more heat out of the appliance?

 The most often cause of diminished heat output is overdue 

maintenance and cleaning .  See “Maintaining and Servic-

ing Appliance” in the owner’s manual.  If this still does not 

help, verify the correct settings for maximum heat output.  

See “Feed Rate Adjustment” under “Operating Instructions” 

in the owner’s manual.

What should I do if I smell smoke or there is ash/soot 

coming from the appliance? 

While there will always be some smoke smell from wood 

burning appliances (including pellet) you  should investigate 

all venting to make sure it is sealed properly. Most vent-

ing requires silicone to seal the seams.  In addition most 

homes are built very tight today and with exhaust systems 

can create negative pressure in the home. See “Negative 

Pressure” under “Getting Started” in the owner’s manual if 

you have checked the venting but still have smoke coming 

from the appliance. For ash or soot check the above and 

the exhaust blower housing and seals. 

      

Why would my appliance run fine last winter but not 

start this fall? 

It is possible that the stove was not properly prepared for 

the Non-burn season. See “Trouble shooting” in the own-

er’s manual.

Why would the metal on the inside of the appliance 

begin to flake?

 

There are some pellet mills that get their raw materials 

from lumber mills that purchase logs that are transported 

in sea water.  These pellets can have a higher salt content 

and cause the metals in the unit to corrode prematurely 

and deteriorate.  If you are seeing any components inside 

the firebox deteriorate it is recommended to change pellet 

brands immediately. 

Why does only the exhaust blower run when I unplug 

and plug back in my appliance?  

This is a Safety feature to prevent the unit from operating in 

an unsafe condition. Allow the unit to run and it will return to 

normal operation.  

Is there a place to lubricate the blowers to quiet them 

down? 

 

The most often cause of noisy blowers is from the impellers 

becoming dirty over time. See “General Maintenance & 

Cleaning” under “Maintaining & Servicing Appliance” in the 

owner’s manual.  No form of lubrication should ever need 

applied to the blowers.

Why are different components cycling on and off in my 

appliance at random? 

The selector switch on control box may be on the wrong 

setting. Refer to the Reference Materials section of our 

owner’s manual for details. 

What is the metal object with the bend in it for that 

came inside the plastic bag? 

 It is a clean-out tool used to help clean the firepot and 

remove any jams in the rare event they occur in the feed 

tube.

Why is there a black residue building up on the outside 

of my home?

 Wind can cause this to happen.  If the appliance  is operat-

ing correctly very little soot should ever exit the termination 

cap.  Also check to be sure the venting is installed per the 

owner’s manual and local codes.

Do I need an outside air kit? 

 Outside air is required for mobile home installs and in 

some jurisdictions.  Refer to “Listing & Code Approvals”,“ 

Mobile Home Installation” and “ Appliance Set-up” owner’s 

manual. Also refer to local building codes.

I am seeing sparks coming out of my pipe (termination 

cap) outside is this safe?  

This is normal.  As long as clearances to combustibles 

were followed this is safe.   

My unit sounds like a freight train at times what can be 

done to eliminate this?

This is referred to as Rumbling.  Maintenance may be 

needed see “Maintaining and Servicing appliance” in the 

owner’s manual.  Decrease fuel flow see “Feed rate adjust-

ment” under Operating Instructions”.   

 

Why does my unit run fine on high, but shuts down on 

low and medium? 

Maintenance may be needed see “Maintaining and Servic-

ing Appliance” See also “Trouble Shooting”.

Can I use another brand of wall thermostat or remote 

system?

Yes, any remote/wall thermostat system that does not 

require power from the appliance should work. 

 I have no power to anything.  Does this unit have a 

circuit breaker or fuse or a reset button?

 This unit has one serviceable fuse in the junction box and 

a reset button for the thermostat circuit.

Can I burn corn in my unit?

Corn is not an approved fuel for the ECO units.  

I’m thinking about going green (solar power) and need 

to know what the power consumption is on my Unit.

PS50 115 VAC, 60 Hz, Start 5.1 Amps, Run 3.0 Amps.  

PS35 115 VAC, 60 Hz, Start 3.8 Amps, Run 1.3 Amps.

CAB50

  

115 VAC, 60 Hz, Start 5.1 Amps, Run 3.0 Amps

  

 

Where is the  serial # of my unit is located?

 The serial # is located on the back of the stove.

Содержание ECO-ADV-PS35

Страница 1: ...operty damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING CAUTION Tested and approved...

Страница 2: ...émas l indiquent Mesurez la distance du devant I de la surface de la porte vitrée 2015 2016 2017 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 34 400 34 400 4001508 ECO ADV PS35 Conforms to ASTM STD E1509 Certified to ULC STD S627 ULC ORD C1482 M1990 Room Heating Pellet Burning Type UM 84 HUD FOR USE ONLY WITH PELLETIZED WOOD FUEL Do not use any other type of fuel B Sample of Serial Number Safet...

Страница 3: ... F Before Your First Fire 8 G Hopper Lid Latch and Hopper Switch 9 H Starting Your First Fire 9 I Fire Characteristics 10 J Feed Rate Adjustment Instructions 10 K Ignition Cycles 10 L Clear Space 10 M Quick Start Guide 11 N Frequently Asked Questions 12 3 Maintenance and Service 13 A Proper Shutdown Procedure 13 B Quick Reference Maintenance Chart 13 C General Maintenance 13 D High Ash Fuel Conten...

Страница 4: ...be free from defects in materials and workmanship at the time of manufacture After installation if cov ered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period HHT will at its option repair or replace the covered components HHT at its own discretion may fully discharge all of its obligations under such warranties by replacing t...

Страница 5: ...tightly sealed constructions insufficient make up air supply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operating instructions 7 installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly...

Страница 6: ...th 5mm ceramic glass Please contact your dealer for replacement glass D Electrical Rating on high Model PS35 115 VAC 60 Hz Start 3 8 Amps Run 1 3 Amps Model PS50 115 VAC 60 Hz Start 5 1 Amps Run 3 0 Amps Model CAB50 115 VAC 60 Hz Start 5 1 Amps Run 3 0 Amps E Mobile Home Approved This appliance is approved for mobile home installa tions when not installed in a sleeping room and when an outside com...

Страница 7: ...sh content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets high ash pellets Lower Ash Content Material Softwoods Fuels with low mineral content Premium grade pellets Clinkers Minerals and other non combustible materials such as sand will turn into a hard glass like substance called a clinker when heated in the firepot Trees from diff...

Страница 8: ...will go off and the appliance will shut down 2 Heat Output Controls This appliance is equipped with a heat output control switch that has three settings or burn rates low medium and high Figure 8 1 The appliance will turn on and off as the thermostat demands When the thermostat calls for heat the appliance will start up at the burn rate for which it is set If the appliance is set at one of the low...

Страница 9: ...trol switch mounted on the back of the appliance in the upper left corner Figure 8 1 on page 8 Turn it to the high setting by pushing the top of the control switch in and then adjust the thermostat to its highest setting 4 Look through the hole in the left lower side panel and you will see the red call light on the control box will be on Figure 9 3 This indicates the thermostat is calling for heat...

Страница 10: ...ely 10 minutes This blower transfers heat from your appliance into the room and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down 3 Occasionally the appliance may run out of fuel and shut itself down When this happens the red call light will be on See Figure 9 3 page 9 To restart it fill the hopper and press the reset button When you press t...

Страница 11: ...cord into the wall receptacle Turn the thermostat on Turn the thermostat to off If the feed tube is empty or this is the first fire add a handful of pellets to the firepot Do not add extra fuel to the firepot if the feed tube has already been primed Overfilling the fire pot will cause smoky start ups If the fire dies out after a few minutes of operation it will be nec essary to push the reset butt...

Страница 12: ... lubricate the blowers to quiet them down The most often cause of noisy blowers is from the impellers becoming dirty over time See General Maintenance Cleaning under Maintaining Servicing Appliance in the owner s manual No form of lubrication should ever need applied to the blowers Why are different components cycling on and off in my appliance at random The selector switch on control box may be o...

Страница 13: ...ng on the fuel type OR X Blower Convection Every 25 bags or more fre quently depending on operat ing environment OR X Door Handle Gasket Inspection Prior to heating season OR X Exhaust Path Drop Tube and Behind Baffles Every 25 bags or more fre quently depending on ash build up OR X Firepot Cleaning Rod Every 1 bag of fuel OR X Firepot with Clean out Tool Every 5 bags of fuel OR X Firebox Prepare ...

Страница 14: ...is loose If the rod is hard to pull it may be necessary to use your firepot clean out tool to chip away material that has built up on the bottom plate of the firepot and to push out any clinkers while in the open position d To close the firepot floor slightly raise the cleaning rod and then push it back into place If you have closed the cleaning rod properly pushed all the way in you will not see ...

Страница 15: ...hopper to prevent sawdust build up A combination of sawdust and pellets on the bottom end of the auger reduces the amount of fuel supply to the firepot This can result in nuisance shutdowns and mis starts a The appliance must be in complete shutdown Allow the appliance to completely run out of pellets and cool down b Empty the hopper of any remaining pellets c Vacuum the hopper and feed tube NOTE ...

Страница 16: ...direct access to the exhaust blower d Vacuum the blower s impellers Use care not to bend or damage the blower fins NOTE Hearth Home Technologies recommends to use a heavy duty vacuum cleaners specifically designed for solid fuel appliance cleaning 12 Cleaning Convection Blower Requires No Lubrication Frequency Yearly or more frequently depending on Dust Dirt build up By Homeowner or Qualified Serv...

Страница 17: ... or lack of maintenance can cause the firepot to overfill Follow proper shutdown procedure if ash buildup exceeds halfway point in firepot Failure to do could result in smoking sooting and possible hopper fires Figure 17 3 Figure 17 1 Figure 17 2 Correct Flame Height Yellow White in Color Incorrect Flame Height Tall Lazy Flame Orange in Color Pellets Back up in Feed Tube Ash build up in Firebox Fi...

Страница 18: ...age Replace control box Close Hopper Lid Check hopper switch operation Check adjust magnet position Call light on No fire Partially burned fuel in firepot Firepot is dirty missed ignition Vent system plugged Igniter chamber blocked Clean firepot Make sure there is no clinker in the firepot Close firepot bottom plate Clinkers may have to be broken up with firepot clean out tool or other means Check...

Страница 19: ...lowing into the venting system can pressurize the firebox causing loss of vacuum Replace vacuum switch Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Remove feed assembly check for obstruction Check that set screw is tight on feed spring shaft at end of feed motor Check connections on feed motor replace i...

Страница 20: ...venting system Clean exhaust path Try a different brand of pellets Reduce feed rate using feed rate adjustment control rod located inside hopper See owner s manual for correct setting for your model and how to adjust control box setting Nuisance shutdowns Low flame Sawdust buildup in hopper Feed motor is reversing Feed motor is weak Feed bearing adjustment Defective thermocouple Defective control ...

Страница 21: ...nylon wire retainer if applicable Model ECO ADV PS35 has 2 black wires and Model ECO ADV PS50 and ECO CAB50 has 1 black and 1 white wire coming from the blower 7 Remove the wing bolt and move the blower and hold down bracket toward the back of the appliance to release the locating tab Figure 21 3 Pull the blower out from under the convection plenum Slide the blower out of the appliance Disconnect ...

Страница 22: ...to the appliance 6 Re install in reverse Snap Disc 2 Fuel Delivery Interrupt 1 Turn down thermostat let appliance cool completely if running Then unplug appliance before servicing 2 Using 2 Phillips screwdriver 3 8 wrench or 3 8 socket loosen the three screws that hold the right upper and lower side panels in place You do not need to remove the screws Remove side panels by lifting up and out 3 Sna...

Страница 23: ...irepot cleaning rod etc 5 Re install the ash drawer and side panel and re connect the power E Baffle Removal Replace 1 Shut down the appliance by turning down the thermostat and let the appliance completely cool down 2 Remove the center baffle first by using the handle at the top of the baffle and pull up and then towards you The hooks on the baffle will slide out of the slots in the bracket Figur...

Страница 24: ...ury WARNING F Glass Replacement 1 Open the door from the appliance by lifting door off of hinge pins and lay on a flat surface face down 2 Using a Phillips Head screw driver remove the 4 brackets and set aside Figure 24 1 3 Remove old glass and replace with the new glass 4 Re install the brackets using the same screws Glass Assembly 1 2 3 4 Remove the 4 brackets outlined in the diagram Figure 24 1...

Страница 25: ...ring harness are replaced as one component 11 Power Supply The power outlet is located behind the control box on the back of the appliance lower left corner Check the wall receptacle for 120 volt 60 Hz standard current Make sure the outlet is grounded and has the correct polarity A good surge protector is recommended When describing the location of a component it is always AS YOU FACE THE FRONT OF...

Страница 26: ...is an orange and a black wire connected to it This snap disc will turn off the feed system which will turn off the appliance if an over fire condition should occur or if the convection blower should fail to operate If this occurs you will have to manually reset the snap disc 18 Snap Disc 3 Back Burn Protector 250 F Snap disc 3 is mounted on the back of the auger tube in the center of the appliance...

Страница 27: ...x Junction Box Red Call Light Fuse Convection Blower LOCATED BEHIND LEFT SIDE PANELS Feed Motor Vacuum Switch Combustion Blower LOCATED BEHIND RIGHT SIDE PANELS Back of Appliance Power Outlet Terminal Block Center 2 Screws for Thermostat Wires Heat Output Switch Reset Button B Component Locations ...

Страница 28: ...inning Manufacturing Date Apr 2010 Ending Manufacturing Date Active ECO ADV PS35 Part number list on following page Free Standing Pellet Stove 1 2 4 5 6 7 3 8 9 10 14 15 16 12 13 11 17 18 19 20 21 23 25 24 26 29 30 28 27 22 08 16 C Exploded Drawings Service Parts PS35 ...

Страница 29: ...1680 Y 6 1 Thermocouple Protection Tube SRV7034 186 Y 6 2 Half Clip 7000 321 6 3 Thermocouple 812 4470 Y 7 Firepot Assembly SRV7034 072B Y Gasket Firepot 7034 190 Y 8 Firepot Bottom 7034 153 Y 9 Rail Auto Clean SRV7034 152 Y 10 Spring Pkg of 4 7000 513 4 Y 11 Hitch Pin Clip 3 32 Pkg of 10 7000 374 10 Y 12 Pull Rod SRV7058 141 13 Heating Element Assembly 18 Loop Igniter Pkg of 1 SRV7000 462 Y Pkg o...

Страница 30: ...ual Reset Left 230 1960 Y 25 Feed Assembly SRV7058 007 Y Feed Bearing SRV7000 598 Y Feed Motor 812 4421 Y Feed Spring Assembly Only SRV7001 046 Y 26 Snap Disc SRV230 1290 Y 27 Side Curtain Right SRV7058 124 28 Vacuum Switch SRV7000 531 Y 29 Hopper Switch SRV7000 612 Y 30 Bumper Rubber Pkg of 12 SRV224 0340 12 Y Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Component Pack SRV7058 019 Cleanout Too...

Страница 31: ...44 Outside Air Collar Assembly 7001 045 Trim Plate Outside Air Kit 412 7100 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y Thermostat Programmable 811 0520 Top Vent Adapter TPVNT 5 Component Pack SRV7058 054 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Fastener Packs Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head Pkg of 10 ...

Страница 32: ...inning Manufacturing Date Apr 2010 Ending Manufacturing Date Active ECO ADV PS50 Part number list on following page Free Standing Pellet Stove 1 2 4 5 6 7 3 8 9 10 14 15 16 12 13 11 17 18 19 20 21 23 25 24 26 29 30 28 27 22 08 16 D Exploded Drawings Service Parts PS50 ...

Страница 33: ...80 Y 6 1 Thermocouple Protection Tube SRV7034 186 Y 6 2 Half Clip 7000 321 6 3 Thermocouple 812 4470 Y 7 Firepot Assembly SRV7034 072B Y Gasket Firepot 7034 190 Y 8 Firepot Bottom 7034 153 Y 9 Rail Auto Clean SRV7034 152 Y 10 Spring Pkg of 4 7000 513 4 Y 11 Hitch Pin Clip 3 32 Pkg of 10 7000 374 10 Y 12 Pull Rod SRV7058 141 13 Heating Element Assembly 18 Loop Igniter Pkg of 1 SRV7000 462 Y Pkg of ...

Страница 34: ...ual Reset Left 230 1960 Y 25 Feed Assembly SRV7058 007 Y Feed Bearing SRV7000 598 Y Feed Motor 812 4421 Y Feed Spring Assembly Only SRV7001 046 Y 26 Snap Disc SRV230 1290 Y 27 Side Curtain Right SRV7059 124 28 Vacuum Switch SRV7000 531 Y 29 Hopper Switch SRV7000 612 Y 30 Bumper Rubber Pkg of 12 SRV224 0340 12 Y Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Component Pack SRV7058 019 Cleanout Too...

Страница 35: ... 044 Outside Air Collar Assembly 7001 045 Trim Plate Outside Air Kit 412 7100 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y Thermostat Programmable 811 0520 Top Vent Adapter TPVNT 5 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Fastener Packs Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head Pkg of 10 25221A 10 Y Guide Pin Sle...

Страница 36: ...inning Manufacturing Date May 2011 Ending Manufacturing Date Active Part number list on following page Pellet Cabinet Style Stove 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 20 25 24 23 22 26 27 28 29 30 08 16 E Exploded Drawings Service Parts CAB50 ...

Страница 37: ...ssembly SRV7058 014 4 1 Glass Assembly SRV7058 015 Y 4 2 Rope Door 3 4 X 84 832 1680 Y 4 3 Hinge Pin 1 2 Nickel 430 5320 4 4 Spring Handle 1 2 Nickel 250 8330 Y 4 5 Door Handle Assembly SRV7058 030 Y Gasket Glass Tape 3 4 X 1 8 5 Ft 832 0460 Y 5 Bumper Rubber SRV224 0340 12 Y 6 Baf e Assembly SRV7059 026 7 1 Thermocouple Protection Tube SRV7034 186 Y 7 2 Half Clip 7000 321 7 3 Thermocouple 812 447...

Страница 38: ... Blower Round 812 4710 Y 19 Casting Exhaust Transition 180 0190 20 Convection Blower 220 CFM SRV7000 108 Y 21 Wire Harness SRV7058 150 Y 22 Blower Retainer SRV7058 148 23 Control Board 3 Speed Eco Choice SRV7058 188 Y 24 Snap Disc F110F 20 1 SRV230 1220 Y 25 Snap Disc L175F Manual Reset 2 230 1960 Y 26 Feed Assembly SRV7058 007 Y Feed Bearing SRV7000 598 Y Feed Motor 812 4421 Y Feed Spring Assembl...

Страница 39: ...Outside Air Kit 412 7100 Outside Air Kit 3 OAK 3 Reset Button Assembly SRV7000 040 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y Thermostat Programmable 811 0520 Top Vent Adapter TPVNT 5 Touch Up Paint 812 0910 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Baf e Center Back SRV7058 166 Fastener Packs Rivnut Repair Kit RIVNUT REPAIR Y Bolt Hex Head 1 4...

Страница 40: ...olville WA 99114 Division of HNI INDUSTRIES Please contact your Heatilator dealer with any questions or concerns For the number of your nearest Heatilator dealer log onto www heatilator com This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pert...

Отзывы: