August 30, 2016
7058-206E
21
HEATILATOR ECO CHOICE
A. Convection Blower Replacement
1. Turn down the thermostat, let appliance completely cool
and then unplug appliance before servicing.
2. The convection blower is located on the floor at the rear
of the appliance.
3. Lift the hopper lid up until it locks into place.
4. Loosen the 4 screws on the upper back panel and the 2
screws on the lower back panel, using a #2 Phillip Head
screwdriver, a 3/8 inch wrench or a 3/8 Inch socket. You
do not need to remove them.
Figure 21.1
.
5. Remove the left upper and lower side panels by lifting
up and out. The hooks on the panels will slide out of the
slots on the appliance.
Figure 21.2.
6. Release blower wires from the nylon wire retainer if
applicable. Model ECO-ADV-PS35 has 2 black wires
and Model ECO-ADV-PS50 and ECO-CAB50 has 1
black and 1 white wire coming from the blower.
7. Remove the wing bolt and move the blower and hold-
down bracket toward the back of the appliance to
release the locating tab.
Figure 21.3
. Pull the blower
out from under the convection plenum. Slide the blower
out of the appliance. Disconnect the wires from the
spade connectors at this time.
Figure 21.4.
8. Return wires to nylon wire retainer. Make sure wires do
not contact any moving parts or touch any surfaces that
may become hot
Figure 21.4.
5
Service Parts Replacement
Loosen Screws,
Do Not Remove
Figure 21.1
Figure 21.2
Figure 21.3
Figure 21.4
Locating Tab
Hold Down Bracket
Spade
Connectors
Nylon Wire
Retainer
Wing Screw
Upper Left
Panel
Lower Left Panel
Lift Up and Out of Slots
Remove left baffle
Lift up to remove
hooks from slots