background image

____________________________________________________________________________________ 

10 

 

Manual Operation 

 
 
 
 

 

NOTE

The unit must be turned off before operating 

the manual control button. If the unit is operational, 
continue pressing the manual control button until the 
unit is off. 
 

Grasp both sides of the panel and pull it down, the 
panel opened upward to an angle of 15

°

. Push the 

panel upward and then lift it up.  

 

One press of the manual control button will lead to 
the forced AUTO operation. If press the button 
twice within five seconds, the unit will operate 
under forced COOL operation.  

 

Close the panel firmly to its original position.  

 
CAUTION

 

This button is used for testing purposes only. You 
had better not choose it.  

 

To restore the remote controller operation, use the 
remote controller directly.

 

 

 
 

ADJUSTING AIR FLOW 

 

 

Adjust the air flow direction properly otherwise, it 
might cause discomfort or cause uneven room 
temperatures.  

 

Adjust the horizontal louver using the remote 
controller.  

 

Adjust the vertical louver manually or by the 
remote controller(depending on the models) 

 

To set the vertical air flow(Up--Down) direction 

 
Perform this function while the unit is in operation. Use 
the remote controller to adjust the air flow direction. 
The horizontal louver can be moved at a angle of 6° for 
each press or set to move up and down automatically. 
Please refer to the “REMOTE CONTROLLER 
ILLUSTRATION” for details. 
 

To set the horizontal air flow direction (left - right) 

 
Adjust the vertical louver manually using the lever on 
the left or right side of the vertical louver arm 
(Depending on model). Take care not to catch fingers 
on the fan, horizontal louver or to damage vertical 
louvers. When the air conditioner is in operation and 
the horizontal louver is in a specific position, move the 
lever at left (or right, depending on model) end of the 
air outlet to the desired position. 

NOTE

: For some 

models, it can be controlled automatically by the 
remote controller. Please refer to the “REMOTE 
CONTROLLER ILLUSTRATION” for details. 

 

 
 
 
 
 
 
 
 

Содержание ECO940SD

Страница 1: ...dance with the national wiring standards by authorized personnel only Contact the authorised service technician for repair or maintenance of this unit User Manual Register your air conditioner Model i...

Страница 2: ...ogy Your new EcoAir high efficiency room air conditioner will give you many years of dependable service Many features have been built into your EcoAir air conditioner to assure quiet operation the bes...

Страница 3: ...ing tips If you review the chart of Troubleshooting Tips first you may not need to call for service CAUTION Contact an authorised service technician for repair or maintenance of this unit Contact the...

Страница 4: ...ic household waste For disposal A Contact your local council for disposal B The manufacture will take back the old appliance for disposal when you replace with a new product C Old products contain val...

Страница 5: ...p environment It may cause electric shock Do not allow water to run into electric parts It may cause failure of machine or electric shock It may cause electric shock or fire If the power cord is damag...

Страница 6: ...ing it out Failure to do so may cause electric shock and damage Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure If bracket is damaged there is co...

Страница 7: ...arts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading...

Страница 8: ...troller holder 11 Remote controller Outdoor Unit 12 Connecting cable 13 Connective pipe 14 Stop valve DISPLAY WINDOW DEFROST operation display Displayed when the air conditioner starts defrosting auto...

Страница 9: ...DRY mode Before select the function it is recommended to run the air conditioner under Cooling operation for about half an hour Once the Self Clean function is activated all TIMER settings will be can...

Страница 10: ...neven room temperatures Adjust the horizontal louver using the remote controller Adjust the vertical louver manually or by the remote controller depending on the models To set the vertical air flow Up...

Страница 11: ...t with horizontal louvre in closed position When the air conditioner is connected to power initial power the horizontal louvre may generate a sound for 10 seconds this is a normal operation Optimal op...

Страница 12: ...y operation During the dry operation if the room temperature is lower than 10 C the compressor stops operation and restarts until the room temperature is above 12 C Operation Tips The following events...

Страница 13: ...he compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling an...

Страница 14: ...or similar solvents for cleaning These may cause the plastic surface to crack or deform Cleaning the air filter NOTE Supply power must be disconnected before cleaning the indoor unit A clogged air fi...

Страница 15: ...t collector with mild detergent or water and dry in the sunlight for two hours Before re install the Plasma dust collector check whether the Y Series or support frame is damaged or not Install the air...

Страница 16: ...ecurely in wall receptacle Fuse may have blown Replace the fuse Battery in Remote controller may Replace the battery have been exhausted The time you have set with timer Wait or cancel timer setting i...

Страница 17: ...RANTY VOID The actual product may differ slightly from the illustration This warranty is in addition to and does not affect your statutory rights For after sales needs please visit www ecoair org serv...

Отзывы: