7.
Make sure both O-rings are on the threaded connector.
8.
Slide the PCB into the enclosure until the two tangs “click”.
9.
Put the nut on and tighten ONLY ½ turn from where it is seated. If this nut is tightened
too much, the connector will crack and the enclosure will not be sealed.
10.
The lambda module is now in EIB mode and can be on the EIB with a display.
To convert a module from EIB to Stand-alone Mode
The process is similar to the previously-described procedure. Note that in EIB mode, the module
will not show up in the device list of the configuration program.
1.
Use the Configuration Tool (software) to “Set to Stand-alone Mode”.
2.
Install the jumper on JP4 in the lambda module.
3.
In Stand-alone Mode, the module will continuously broadcast data via 500kbps CAN.