31
Appendix D:
Process Data Objects
Address Type Symbol Description
0x2000 single
float
NOX
PDO Data NOx (ppm)
0x2001 single
float
O2R
PDO Data O2real (%)
0x2002 single
float
IP1
PDO Data Ip1 (A)
0x2003 single
float
IP2
PDO Data Ip2 (A)
0x2004 single
float
RPVS
PDO Data RPVS (ohms) * 1000
0x2005 single
float
VHCM
PDO Data VH Commanded (V) * 1000
0x2006 single
float
VS+
PDO Data VS (V) * 1000
0x2007 single
float
VP1P
PDO Data VP1+ (V) * 1000
0x2008 single
float
VP2
PDO Data VP2 (V) * 1000
0x2009 single
float
VSW
PDO Data Vsw (V) * 1000
0x200A single
float
VH
PDO Data VH Measured (V) * 1000
0x200B single
float
TEMP
PDO Data Board Temperature (deg C) * 100
0x200C single
float
IP1R
PDO Data Ip1raw (bits)
0x200D single
float
PR16
PDO Data Ip2raw (bits)
0x200E single
float
ERFL
PDO Data Error bit flags
0x200F single
float
ERCD
PDO Data ECM CANOpen Error Code
0x2010 single
float
PR10
PDO Data Praw (bits)
0x2011 single
float
PCF
PDO Data PCF (Pressure Correction Factor) * 10000
0x2012 single
float
Reserved
0x2013 single
float
Reserved
0x2014 single
float
Reserved
0x2015 single
float
Reserved
0x2016 single
float
P
PDO Data Pressure (mmHg)
0x2017 single
float
LAMR
PDO Data LAMBDAreal
0x2018 single
float
AFR
PDO Data AFR
0x2019 single
float
PHI
PDO Data PHI
0x201A single
float
FAR
PDO Data FAR
0x201B single
float
LAM
PDO Data LAMBDA
0x201C single
float
O2
PDO Data O2 (%)
0x201D
single float IP1X
PDO Data Non pressure compensated Ip1 (A)
0x201E
single float PVLT
PDO Data Pressure (V)
0x201F
single float PKPA
PDO Data Pressure (kPa)
0x2020
single float PBAR
PDO Data Pressure (bar)
0x2021
single float PPSI
PDO Data Pressure (psi)