ENGLISH
Translation of the original German user manual
22
3.2 Control panel
The lights above the buttons are all on when the machine is
operational.
The ECM button regulates the manual dispensing and allows to
program several functions (see chapter 5.2).
The display indicates the current brewing time.
The dispensing is started by pressing the button and pressing it
again to stop.
After having pressed a button (1-3), only that respective light will
be illluminated. The shot counter counts until the preset or
programmed value has been reached (see chapter 5.2).
After that, the lights above all buttons will light up again.
3.3 Technical data
Voltages:
3 phases, 230 V each
Power:
3.000 W
Boiler capacity:
9 L, 2 heat exchangers
Measurements:
W x D x H / 650 mm x 510 mm x 480 mm without portafilter
3.4 Connection plan
1
Connection for water
drainage
2
Connection for water
supply
3
Power cord
Dimensions in mm
Connection plan (top view)
1
2
3
front