Eclipse BoostPak Скачать руководство пользователя страница 2

2

Copyright

Copyright 2010 by Eclipse, inc. All rights reserved
worldwide. This publication is protected by federal
regulation and shall not be copied, distributed,
transmitted, transcribed or translated into any human or
computer language, in any form or by any means, to any
third parties, without the express written consent of
Eclipse, inc.

Disclaimer Notice

In accordance with the manufacturer’s policy of continual
product improvement, the product presented in this
brochure is subject to change without notice or obligation.

The material in this manual is believed adequate for the
intended use of the product. If the product is used for
purposes other than those specified herein, confirmation
of validity and suitability must be obtained. Eclipse
warrants that the product itself does not infringe upon any
United States patents. No further warranty is expressed or
implied.

Liability & Warranty

We have made every effort to make this manual as
accurate and complete as possible. Should you find errors
or omissions, please bring them to our attention so that we
may correct them. In this way we hope to improve our
product documentation for the benefit of our customers.
Please send your corrections and comments to our
Technical Documentation Specialist.

It must be understood that Eclipse’s liability for its product,
whether due to breach of warranty, negligence, strict
liability, or otherwise is limited to the furnishing of
replacement parts and Eclipse will not be liable for any
other injury, loss, damage or expenses, whether direct or
consequential, including but not limited to loss of use,

income, or damage to material arising in connection with
the sale, installation, use of, inability to use, or the repair
or replacement of Eclipse’s products. 

Any operation expressly prohibited in this manual, any

adjustment, or assembly procedures not recommended or 
authorized in these instructions shall void the warranty. 

Document Conventions

There are several special symbols in this document. You
must know their meaning and importance.

The explanation of these symbols follows below. Please
read it thoroughly.

How To Get Help

If you need help, contact your local Eclipse
representative. You can also contact Eclipse at:

1665 Elmwood Rd.
Rockford, Illinois 61103 U.S.A.
Phone: 815-877-3031
Fax: 815-877-3336
http://www.eclipsenet.com

Please have the information on the product label available
when contacting the factory so we may better serve you.

Product Name
Item #
S/N
DD MMM YYYY

www.eclipsenet.com

This is the safety alert symbol. It is used to alert you to potential personal
injurt hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.

Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.

Is used to address practices not related to personal injury.

Indicates an important part of text. Read thoroughly.

NOTE

NOTICE

CAUTION

WARNING

Содержание BoostPak

Страница 1: ...Eclipse BoostPak Leak Detection Option 630 LD Install Guide 7 30 2010 Version 3 ...

Страница 2: ... and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to material arising in connection with the sale installation use of inability to use or the repair or replacement of Eclipse s products Any operation expressly prohibited in this manual any adjustment or assembly procedures not recom...

Страница 3: ... result Never try to operate a BoostPak if it shows signs of damage or malfunction This manual provides information in the use of the BoostPak for its specific design purpose Do not deviate from any instructions or application limits described herein without written advice from Eclipse Capabilities Only qualified personnel with good mechanical aptitude and experience with combustion equipment shou...

Страница 4: ...t room at eye level The panel must be secured to the wall and conduits to it must be separately supported The panel will need 3 conduit entrances 120VAC power supply from building circuit breaker 3 wires sized to handle 10 amps plus additional loads connected to the alarm terminals 120VAC power and switch signal to gas valve 3 wires not smaller than 18 gauge as determined by local codes 120VAC pow...

Страница 5: ... of the gas valve If a direct connection is needed it can be wired in series with the run interlocks or in series with the low inlet gas switch When connected to the run interlocks a leak detect will provide a normal shutdown of the BoostPak refer to the appropriate installation guide When connected to the low inlet gas a leak detect will result in an alarm condition shutdown Checklist After Insta...

Страница 6: ... at first and second alarm points Commissioning Record Nameplate Information Leak Detect Module Serial Number ___________ Annunciation Control Panel Serial Number ___________ Mechanical Installation Ambient Temperature ___________ Panel Mounting Secure Rigid Level ___________ Conduit Properly Supported ___________ Proper and Adequate Detector Location ___________ Leak Detector Performance Alarm A ...

Страница 7: ... indicate the gas concentration reaches alarm level A and B for both sensors When the methane concentration reaches the first alarm level Alarm A panel relay CR127 changes state If the gas concentration reaches the second alarm level Alarm B panel relay CR128 changes state and the audible alarm comes on Annunciation Control Panel Operation On initial application of power from the building circuit ...

Страница 8: ...pond properly return to the manufacturer for repair If field adjustments are required the optional display is needed Flow a span gas at the recommended rate and observe the action of the LEDs and outputs Span gas can be purchased through your local industrial gas supplier Troubleshooting Guide Problem Possible Cause Solution No lights at annunciation panel Power supply to panel disconnected not po...

Страница 9: ...9 Eclipse BoostPak Leak Detection Option V3 Installation Guide 630 LD 7 30 2010 Panel Layout Enclosure and Terminal Strip Enclosure 14 H x 12 W x 6 D 10 40 30 20 Panel 12 75 H x 10 88 W ...

Страница 10: ...rminal on device Panel ground lug Used for indexing to sheet X and line Y KEY CUSTOMER SUPPLIED LEAK DETECT ENCLOSURE TERMINALS ARE NOT SHOWN IN CORRECT ORDER AND ARE FOR REFERENCE ONLY ON THIS DWG SEE PANEL LAYOUT DWG FOR TB1 TERMINAL STRIP LAYOUT REMOTE COMBUSTIBLE GAS SENSOR SHIELD 125GLD 118FAN SWITCH PROOF OF CLOSURE POSITION SWITCH OPEN POSITION 108SOL SSOV COMM COMM NC NO G Item Number Ecli...

Страница 11: ...ter mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From To Multiply By actual cubic foot h acfh actual cubic meter h am h 2 832 x 10 2 standard cubic foot h scfh normal cubic meter h Nm h 2 629 x 10 2 degrees Fahrenheit F degrees Celsius C F 32 x 5 9 pou...

Страница 12: ...Installation Manual 630 LD 7 30 10 ...

Отзывы: